BEGA 23297 LED Ceiling and Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 23297 LED Ceiling and Wall Luminaire

BEGA-23297-LED-Ceiling-and-Wall-Luminaire-PRODUCT

Product Information

This luminaire is designed for installation and operation in accordance with national safety regulations. It is important to have a qualified electrician carry out the installation and commissioning. The manufacturer does not accept liability for any damage caused by improper use or installation. Any modifications made to the luminaire should be done by a responsible person who will be considered the manufacturer. The electronic components in this luminaire are protected against overvoltage as per DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on our website at www.bega.com. The connected wattage for the lamp module is 31.8 W and for the luminaire is 35 W. The rated temperature and ambient temperature should be within the range of 25°C to 50°C. The module designation is LED-0531/930 with a color temperature of 3000 K. The color rendering index (CRI) is greater than 90. The module luminous flux is 4645 lm and the luminaire luminous flux is 3343 lm. The luminaire luminous efficiency is 95.5 lm/W. During installation or relamping, it is important to avoid touching the light output opening of the LED directly as they are high-quality electronic components. Spare parts available for this product include spare glass, an LED power supply unit, and an LED module with a color temperature of 3000 K. The part numbers are 11 002 772 .0R G, DEV-0391/700, and LED-0531/930 respectively.

Product Usage Instructions

  1. Ensure the luminaire is installed and operated in accordance with national safety regulations.
  2. Only a qualified electrician should carry out the installation and commissioning.
  3. Avoid improper use or installation to prevent any liability issues.
  4. If modifications are necessary, ensure they are done by a responsible person who will be considered the manufacturer.
  5. For additional protection against overvoltage and transients, consider using separate overvoltage protection components available on our website.
  6. The connected wattage for the lamp module should be 31.8 W and for the luminaire should be 35 W.
  7. Maintain a rated temperature and ambient temperature within the range of 25°C to 50°C.
  8. The module designation is LED-0531/930 with a color temperature of 3000 K and a color rendering index (CRI) greater than 90.
  9. The module luminous flux is 4645 lm and the luminaire luminous flux is 3343 lm.
  10. During installation or relamping, avoid touching the light output opening of the LED directly.
  11. If spare parts are needed, refer to the part numbers provided for spare glass, LED power supply unit, and LED module with a color temperature of 3000 K.

DIMENSION

BEGA-23297-LED-Ceiling-and-Wall-Luminaire-
FIG-1

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Product Description

  • Metal housing, finish Colour white
  • Hand-blown opal glass, satin matt, with sliding-bolt closure
  • 2 mounting holes ø 5.5 mm
  • Distance apart 280 mm 2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection 2-pole connection for digital control
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 170-276 V
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect emperature-sensitive components without switching off the luminaire Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies
  • ≥ 1 mm and splash water
  • Impact strength IK04
  • Protection against mechanical impacts < 0.5 joule
    • r – Safety mark
    • c – Conformity mark
  • Weight: 5.2 kg

This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 31.8 W
  • Luminaire connected wattage 35 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

23 297 K3

  • Module designation LED-0531/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 4645 lm
  • Luminaire luminous flux 3343 lm
  • Luminaire luminous efficiency 95,5 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

  • Disassemble the LED module.
  • Loosen LED connection and earth connection (plug connection).
  • Dismantle the mains supply cable max. 80 mm. Lead mains supply cable through the cable entry into the luminaire housing.
  • Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
  • It is imperative to use the enclosed gaskets.
  • Make earth and electrical connections to the terminal.
  • For digital control please use the 2-pole plug connector DA, DA.
  • In case this connector is not used the luminaire will be operated at full light output.
  • Make an earth connection between the LED module and luminaire housing (plug connection).
  • Push LED plugs into couplers as far as it will go.
  • Assemble LED module.
  • Tighten the screws evenly (max. 0,8 Nm).
  • Please observe that the LED module is not damaged mechanically.
  • Place glass to the luminaire housing and observe that the holding spring bolts fit into the notches of the glass.
  • Turn the glass clockwise until it is locked.
  • Thus, you reach a safe and vibration-resistant holding of the glass.
  • To release the glass from the luminaire housing, turn it counterclockwise.

Replacement of the LED module Maintenance
The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system. Unscrew the glass from the luminaire housing by turning it counterclockwise. Clean glass and luminaire regularly with solvent-free cleansers from dirt. Please follow the installation instructions for the LED module. Screw in the glass by turning it clockwise as far as it will go. A broken glass must be replaced.

Spares

  • Spare glass 11 002 772 .0R G
  • LED power supply unit DEV-0391/700
  • LED module 3000 K LED-0531/930

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals