Application
Pivoting recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing. Efficient luminaires for adjustable, brilliant light in the residential living space and for use in many other ranges of interior illumination. For installation into ceilings with a shallow depth in interior areas.
Product description
Recessed ceiling luminaire »ACCENTA VARIO« Die-cast aluminium housing Crystal glass, partially satin matt inside Reflector of anodised pure aluminium Ceiling trim ring made of metal, Colour white Recessed opening ø 95 mm Required installation depth 60 mm Fixing is achieved by using 2 adjustable claws External LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V DALI controllable A basic isolation exists between power cable and control line Safety class II 2 r – Safety mark c – Conformity mark Weight: 0.6 kg This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

  • Lamp
    • Module connected wattage 8.5 W
    • Luminaire connected wattage 10.4 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 35 °C
  • 50 714.1 K27
    • Module designation LED-0923/927
    • Colour temperature 2700 K
    • Colour rendering index CRI > 90
    • Module luminous flux 1155 lm
    • Luminaire luminous flux 581 lm
    • Luminaire luminous efficiency 55,9 lm / W
  • 50 714.1 K3
    • Module designation LED-0923/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 1200 lm
    • Luminaire luminous flux 604 lm
    • Luminaire luminous efficiency 58,1 lm / W

Installation
Luminaire housing must not be installed in heat-insulating material.
The recessed opening will be covered by the
attachement of the installation ring.
Fixing of the luminaire is achieved by using 2
adjustable claws.
LEDs are high-quality electronic components!
Please avoid touching them directly during
installation or relamping.
Installation into false ceilings
A recessed opening of Ø 95 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm. The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the panel must be no more than 20 mm. The notch in the installation ring indicates the direction of maximum pivoting range (35°) of the luminaire housing. Remove glass with reflector from luminaire housing by turning counter-clockwise. The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used. Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires. The connection of the control cables is achieved by means of the both leads marked with – DALI. In case these leads are not used the luminaire will be operated at full light output. Push external LED- power supply unit and luminaire housing into ceiling cut-out.
Luminaire housing and external LED power supply unit must not be installed in heat-insulating material. Hand-tight screws of claw fasteners evenly. Insert glass with mounted reflector by turning it clockwise into luminaire housing. Make sure that gasket is positioned correctly. Mount ceiling frame ring (magnetic) onto installation ring of the housing.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.  Disconnect from main supply.  Remove glass with reflector from the housing by turning it counter-clockwise. Pull ceiling frame ring off the installation ring of the pivoting housing. Please follow the installation instructions for the LED module. Check gasket. Screw in glass with mounted reflector by turning it clockwise into luminaire housing. Mount ceiling frame ring onto the installation ring of the housing. The defective glass must be replaced.

  • Spares
    • Spare glass 11 003 006 410 RG
    • LED power supply unit DEV-0434/250
    • LED module 2700 K LED-0923/927
    • LED module 3000 K LED-0923/930
    • Trim ring 72 009 801 L
    • Reflector 76 001 209

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com