BEGA 50654.2 Ceiling and Wall Luminaire Instruction Manual

June 12, 2024
BEGA

50 654.2
Ceiling and wall luminaire for indoor use
Instructions for use

50654.2 Ceiling and Wall Luminaire

BEGA 50654.2 Ceiling and Wall Luminaire - Fig1

Application

Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks.
They are ideal for places where a soft and uniform lighting distribution is required.

Product description

Metal housing, finish Colour white aluminium
Hand-blown opal glass, satin matt, with sliding-bolt closure 2 mounting holes ø 5.5 mm
Distance apart 240 mm 2 cable entries for through-wiring for mains
cable up to ø 10.5 mm max. 3 × 1.5@
Connecting terminal 2.5@ with plug connection
Earth conductor connection LED power supply unit 220-240 V /50-60 Hz DC 170-280 V
BEGA Thermal Switch ®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 44
Protected against granular foreign bodies ≥ 1 mm and splash water
Impact strength IK07
Protection against mechanical impacts < 2 joule
– Safety mark
 – Conformity mark
Weight: 4.4 kg
This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage| 25.3 W
Luminaire connected wattage| 29 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 40 °C
50 654.2 K3
Module designation| LED-0570/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 3615 lm
Luminaire luminous flux | 1928 lm
Luminaire luminous efficiency
| 66,5 lm / W

  • preliminary data

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or revamping.
Disassemble LED module.
Loosen LED-connection and earth connection (plug connection).
Dismantle the mains supply cable max. 80 mm.
Lead mains supply cable through the cable entry into the luminaire housing.
Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
It is imperative to use the enclosed gaskets.
Make earth and electrical connection to the terminal.
Make earth connection between LED module and luminaire housing (plug connection).
Push LED-plugs into couplers as far as it will go.
Assemble LED module.
Tighten the screws evenly (max. 0,8 Nm).
Please observe that the LED module is not damaged mechanically.
Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn the glass clockwise up to the stop.
Place glass to the luminaire housing and observe that the holding spring bolts fit into the notches of the glass.
Turn the glass clockwise until it is locked.
Thus, you reach a safe and vibration-resistant holding of the glass.
To release the glass from the luminaire housing, turn it counter-clockwise.

Replacement of the LED module Maintenance

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Clean glass and luminaire regularly with solvent-free cleansers from dirt.
Please follow the installation instructions for the LED module.
Screw in glass by turning it clockwise as far as it will go.
A broken glass must be replaced.

Spares

Spare glass| 11 002 771 .0R G
LED power supply unit| DEV-0291/850
LED module 3000 K| LED-0570/930

Technical amendments reserved
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
[email protected] 
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals