BEGA 50710.4 LINE LED Ceiling Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 50710.4 LINE LED Ceiling Luminaire Instruction Manual

BEGA

Deckeneinbauleuchte für die Verwendung im Innenbereich
Recessed ceiling luminaire for indoor use Plafonnier à encastrer pour utilisation à l’intérieur

Recessed ceiling luminaire for indoor use

Instructions for use

Application

Recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing.

For installation into ceilings with a shallow depth in interior areas.


Product description

Recessed ceiling luminaire »ACCENTA« Die-cast aluminium housing

Crystal glass, partially satin matt inside Reflector made of pure, high-gloss anodized aluminium

Ceiling trim ring finish, Brass Recessed opening ø 68 mm Required installation depth 60 mm

Fixing is achieved by using 2 adjustable

wedge-shaped claws

External LED power supply unit 220-240 V x 0/50-60 Hz

Safety class II 2 r – Safety mark c – Conformity mark Weight: 0.22 kg

This product contains light sources of energy

efficiency class(es) E

Safety

The installation and operation of this luminaire

are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.

The manufacturer accepts no liability for damage caused by improper use or installation.

If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.


Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.

To achieve an additional protection against

e. g. transients, etc. we recommend separate overvoltage protection components.

You can find them on our website at

www.bega.com.

Lamp

Module connected wattage                    8.5 W

Luminaire connected wattage                   10.4 W

Rated temperature                            ta = 25 °C

Ambient temperature                    ta max = 35 °C

50 710.4 K27

Module designation                      LED-0923/927

Colour temperature                              2700 K

Colour rendering index                           CRI > 90

Module luminous flux                             1155 lm

Luminaire luminous flux                           581 lm Luminaire luminous efficiency         55,9 lm / W

50 710.4 K3

Module designation                      LED-0923/930

Colour temperature                              3000 K

Colour rendering index                           CRI > 90

Module luminous flux                             1200 lm

Luminaire luminous flux                            604 lm Luminaire luminous efficiency         58,1 lm / W


Installation

l Luminaire housing must not be installed in

heat-insulating material.

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

The recessed opening will be covered by the frame of the luminaire.

Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.

Installation into false ceilings

A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch).

The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the

reverse side. Maximum thickness of the panel

must be no more than 20 mm.

Remove cover of the external LED-power

supply unit.

Loosen set screws of cable strain relief. Tightening zone for strain relief: max. Ø 12mm. Connecting terminals for mains supply:

max. 2,5@.

Strip the wires 6 mm.

Lead mains supply cable through the cable

strain relief and fix set screws.

Make electrical connection.

Close case cover of the external LED-power

supply unit and press it until it is locked. Push external LED-power supply unit and luminaire housing into ceiling cut-out.

Luminaire housing and external LED- power supply unit must not be installed in heat-insulating material.

Hand-tight screws of claw fasteners evenly. Lead enclosed ceiling frame ring over the screw-neck of the glass and push it down the gasket.

Make sure that gasket is positioned correctly. Insert glass with mounted reflector and frame ring by turning it clockwise into luminaire housing.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass with ceiling frame ring from luminaire housing by turning it counter- clockwise.
Please follow the installation instructions for the LED module.
Check gasket. Screw in glass with ceiling frame ring by turning it clockwise beyond the stop.
Defective glass must be replaced.

Spares

LED module 2700 K                                 LED-0923/927
LED module 3000 K                                LED-0923/930
Trim ring                                                    72 009 587 L
Reflector     76 001 209

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals