Product Information

  • Product Name: Mod. 1051
  • Model Number: DS1051-053
  • Product Code: 1051/204
  • Language: Italian

Identification of Parts

  1. LED Indicator / Learn/Test Button
  2. Cover Fixing Screw
  3. Wall Mounting Holes
  4. Tamper Switch
  5. Battery Insulator
  6. Jumper for selecting surface type for the magnet (JP1)
  7. Battery
  8. Magnet
  9. Screws Holes for Magnet Fixing
  10. Magnet Spacer

Jumper Settings

Jumper Default Position
JP1 Included (For using the device as an inertial sensor only)
JP2 OFF OFF ON ON (Default: Glass Surface)
JP3 OFF ON OFF ON (Default: Metal Surface)
JP4 ON (Default: Medium Sensitivity)
JP5 OFF (Default: Low Battery Protection)
  • Battery Installation
    The battery is pre-installed at the factory with an insulating element. Remove the battery insulator to activate the device.

  • Tamper Protection
    The tamper protects the device from tampering or removal from the installation surface.

  • Supervision Test
    Before installation, perform a supervision test to ensure proper functioning of the device.

Product Usage Instructions

Preparation

  1. Remove the battery insulator.
  2. Verify the correct position of the device.

Installation

Follow the steps below for using the device as an opening detector:

  1. Refer to the notches and frames in the table below for positioning the device on different surfaces.
  2. Select the material and detection parameters based on the table below.
  3. Install the device.

Surface Material and Detection Parameters

Thickness| Material| Positioning| Detection Type| Low Sensitivity| Medium Sensitivity| High Sensitivity
---|---|---|---|---|---|---

5mm| Glass Window| Frame| Window Opening| ✓| ✓| ✓
5mm| Door| Door| Door Opening| ✓| ✓| ✓
5mm| Window| Window| Window Opening| ✓| ✓| ✓

Note: The device has a coverage area of up to 1.5m for frame positioning and up to 2m for window and door positioning.
1051/204 is a magnetic contact/shock detector with MEMS technology, designed to generate alarms upon opening of the door or window controlled or in the event of shocks of the surface on which it is applied. The control unit connected to this device will generate a single type of alarm in case of opening or detection of shocks. The device consists of a cover and a base. The cover contains all the electronic components, while the base is used for installing the device. A tamper switch inside provides protection from unauthorised attempts to open or remove the device.

Part identification

  1. LED Indicator/Learning/Test Button
  2. Cover fixing screw
  3. Wall-mounting hole arrangement
  4. Tamper switch
  5. Battery insulation
  6. Jumper for selecting the type of surface to be protected (JP2, JP3)
  7. Jumper for selecting detection sensitivity (JP4, JP5)
  8. Jumper for selecting magnet use mode (JP1)
  9. Battery
  10. Magnet
  11. Magnet fixing screw hole
  12. Magnet spacer
    • Jumper. Default position

LED indicator

In normal operating mode, the LED is off, except for the following situations:

  • When the tamper switch of the device is opened
  • When the battery of the device is flat
  • When the device is in Test mode

The LED does not flash if the tamper switch and the battery of the device are working normally and not in Test mode. The LED flashes to indicate that a signal is being transmitted and flashes rapidly twice when it receives a recognition signal from the control unit.
Management of alarms generated by opening of the magnet
The detection of the alarm generated by the opening of the magnet can be enabled or disabled by jumper JP1:

  • If the jumper is ON (the jumper is inserted on the two pins), detection is deactivated and the shock alarm remain enabled.
  • If the jumper is OFF (jumper removed or “arranged” on a pin), detection is enabled (default setting).

Important note: insert the jumper on JP1 in case you are using the device as inertial sensor only.

Choice of the type of surface to be protected
Using the jumpers JP2 and JP3 it is possible to choose the type of material of which the surface to be protected is composed. Refer to the following table:

JP2 JP3 Surface material
OFF OFF Wood
OFF ON Glass
ON OFF Metal
ON ON Concrete

Sensitivity adjustment
Jumpers JP4 and JP5 can be used to determine the sensitivity required to generate a shock or vibration alarm. See the following table:

JP4 JP5 Sensitivity
ON OFF Low
OFF ON Medium (default )
ON ON High

Battery
The device is powered by a CR123A 3 V lithium battery and can indicate when the battery is flat. When the battery charge is low, the device sends a signal to the control unit together with the normal transmissions. When the battery is flat, the device does not work and the LED blinks every 4 seconds. The battery is pre-installed at the factory with the insertion of an insulating element. Remove the insulation from the battery to activate the device.

Tamper protection

The tamper switch protects the device from tampering attempts or attempts remove it from the installation surface.
Supervision
In normal operation, the device transmits a supervision signal to the control unit at regular intervals during normal operation. The control unit generates a supervision alarm if the control unit does not receive the device signal within the predetermined time.
Test

  • Whenever the Test button is pressed, the device transmits a signal to the control unit to test the radio range and activates Test mode for 3 minutes.
  • In Test mode, the LED lights up whenever an alarm is generated.
  • Test mode is extended by 3 more minutes if the Test button is pressed again.

Preparation

  • Step 1: Remove the battery insulation.
  • Step 2: Enable the learning function on the control unit (see the respective manual for more details).
  • Step 3: Press the Test button on the device to send a signal to the control unit.
  • Step 4: If the control unit receives the signal correctly will respond by emitting beeps. Refer to the manual of the control unit to complete the learning process.
  • Step 5: After the device has been learnt, set the control unit to “Walk Test” mode, by holding the device in the desired position and press the Test button to check that it is within the wireless range of the control unit.
  • Step 6: After having checked the correct position of the device, proceed with the installation.

Installation
Use as opening detector:

  • The detector may be installed in either of the two possible vertical positions.
  • The distance between the device and the magnet must not be more than 15 mm when the door is closed.
  • Avoid installation on metal surfaces, if possible.
  • Install the device as high as possible.

Use as shock detector:

  • The device can be installed on perfectly flat concrete or wood surfaces or on window and door frames.
  • When installed on windows or doors, it can also be used as an opening detector. IMPORTANT NOTE: Detection on multilayer or mesh glass is not guaranteed because the vibrations are attenuated by the materials.urmet-MK-1051-204-White-Mini-Magnetic-Contact-With-Shock-Detector-FIG-1 \(4\)
  • Use the following table as a reference for the selection of materials and detection parameters.
  Window glass Door Masonry
Thickness > 5mm <40mm
Material Normal or tempered Wood/steel Cement/concrete
Positioning Mobile window frame Door frame On the wall near the detection

point
Detection type| Single pulse| Multiple pulse
Detection diameter for different

sensitivities

| Low| 2m| 1m| 0.5m
Medium| 3m| 2m| 1.5m
High| 4m| 3m| 2m

Installation

  1. Open the device by undoing the cover and fixing the screw.
  2. Break the hole pattern on the base.
  3. Using the base as a template for the holes, make the holes in the installation surface.
  4. Insert the anchor bolts.
  5. Screw the base to the anchor bolts using the flat-head screws provided.
  6. Fix the cover to the base and tighten the cover fixing screw.
  7. Fix the magnet with screws or double-sided adhesive tape.

Replacing the battery

  1. Open the device by undoing the cover and fixing the screw.
  2. Remove the flat battery and press the Tamper switch twice to discharge the device completely.
  3. Insert the new CR123A 3V lithium battery in the housing, respecting the correct polarity.
  4. Reposition the cover to the base and fasten the cover fixing screw.

Technical specifications

  • Power: one 3V CR123A lithium battery
  • Battery life: 6 years (typical value, can vary according to use)
  • Radiofrequency of use: 868,6 – 868,7 MHz
  • Radio power transmitted: 1,81 dBm Working temperature range -10°C to +45°C
  • Dimensions: 85 mm x 30 mm x 20 mm
  • Weight: 50g Compliant with EN 50131 Degree 2, ClassⅡ

SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment type: WHITE MINI MAGNETIC CONTACT WITH SHOCK DETECTOR 1051/204 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.urmet.com.
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE). The symbol of the crossed-out wheeled bin on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

urmet User Manuals

Related Manuals