Installation instructions
220-240V AC I 50-60Hz
LIVE – L (F) BROWN
NEUTRAL – N (N) BLUE
EARTH – E YELLOW / GREEN
Installation
-
Set required colour temperature for all units. Switch is located at the back of the floodlight under rubber cover.
Use small screwdriver to lever the cover to access the switch.
Note: Ensure the rubber cover is fitted correctly after selecting the colour temperature. -
Fix the circular wall bracket to the wall. Screws and wall plugs are supplied.
-
Locate the floodlight over the circular wall bracket and tighten the screw to secure it in the required position. The aim of the floodlight can be adjusted by turning/tilting the unit.
-
Connect the flying lead to the mains supply. A suitable waterproof junction box or enclosure must be used to maintain the IP65 rating of the product.
-
Tighten the two side screws to clamp the floodlight in the required position.
Note: When the floodlight is switched on for the first time, you may
notice a slight presence of condensation behind the glass.
The product is fitted with a breathable gland and any condensation will
disappear after several hours of use.
Installation data
- Isolate the mains supply, prior to wiring.
- This unit must be wired by a qualified electrician or suitable competent person.
- The light source of this luminaire is not replaceable.
When the light source reaches it’s end of life the whole luminaire shall be replaced.
Specification
Product | FL05 | FL10 |
---|---|---|
Input voltage | 220-240V AC 50/60Hz | 220-240V AC 50/60Hz |
Input current | 0.23A | 0.46A |
Input power | 50W | 100W |
Power factor | >0.9 | >0.9 |
Inrush current | 28A/15μs | 75A/6μs |
Disposal
Disposal of this product should be separate from household waste. Please
separate these items from other types of waste and recycle them responsibly to
promote the sustainable reuse of material resource. Household
users should contact their local government office for details of where and
how they can take these items for environmentally safe recycling.
5 year warranty
Support
t +44 (0) 1604 495 151
f +44 (0) 1604 495 095
e sales@collingwoodgroup.com
w collingwoodlighting.com
Collingwood Lighting,
Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United
Kingdom
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>