BEGA 34288 LED Ceiling and Wall Luminaire for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA-LOGO

BEGA 34288 LED Ceiling and Wall Luminaire for Indoor Use

Product Information

Parameter Value
Safety The installation and operation of this luminaire are subject to

national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection| The electronic components installed in the luminaire are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc. we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp Module connected wattage| 25.3 W
Luminaire connected wattage| 28.8 W
Rated temperature| Ambient temperature: 25-45°C
Colour temperature| 3000 K
Colour rendering index (CRI)| CRI > 90
Module luminous flux| 3615 lm
Luminaire luminous flux| 2465 lm
Luminaire luminous efficiency| 85.6 lm / W

Product Usage Instructions

LED are high-quality electronic components! Please avoidtouching the light output opening of the LED directly duringinstallation or relamping.

To install the luminaire, follow these steps:

  1. Place the glass to the luminaire housing.
  2. Observe that the holding springbolts fit into the notches of the glass.
  3. Turn the glass clockwise until it is locked. This ensures a safe and vibration-resistant holding of the glass.

To release the glass from the luminaire housing, turn it counter-clockwise.

Dimension

BEGA-34288-LED-Ceiling-and-Wall-Luminaire-for-Indoor-Use-
FIG-1

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks.They are ideal for places where a soft and uniform lighting distribution is required.
Product description
Metal housing, finish Colour white Hand-blown opal glass, satin matt, with sliding-bolt closure 2 mounting holes ø 5.5 mm Distance apart 240 mm 2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@ Connecting terminal 2.5@ with plug connection Earth conductor connection 2-pole connecting terminal for digital control LED power supply unit 220-240 V x 0/50-60 Hz DC 170-276 V DALI-controllable Number of DALI addresses: 1 Basic insulation is provided between the mains and control cables BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 44 Protected against granular foreign bodies ≥ 1 mm and splash water Impact strength IK06 Protection against mechanical impacts < 1 joule r – Safety mark c – Conformity mark Weight: 4.0 kgThis product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only becarried out by a qualified electrician. The manufacturer accepts no liability fordamage caused by improper use or installation. If subsequent modifications are made tothe luminaire, the person responsible forthese modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection againste. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

  • Lamp
    • Module connected wattage 25.3 W
    • Luminaire connected wattage 28.8 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 45 °C
  • 34 288 K3
    • Module designation LED-0570/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 3615 lm
    • Luminaire luminous flux 2465 lm
    • Luminaire luminous efficiency 85,6 lm / W

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Disassemble LED module. Loosen LED connection and earth connection (plug connection). Dismantle the mains supply cable max. 80 mm. Lead mains supply cable through the cable entry into the luminaire housing. Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface. It is imperative to use the enclosed gaskets. Make earth and electrical connections to the terminal. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. Make earth connection between LED moduleand luminaire housing (plug connection).Push LED plugs into couplers as far as it will go. Assemble LED module. Tighten the screws evenly (max. 0,8 Nm).Please observe that the LED module is not damaged mechanically. Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn theglass clockwise up to the stop.
Place glass to the luminaire housing and observe that the holding spring bolts fit into the notches of the glass. Turn the glass clockwise until it is locked. Thus, you reach a safe and vibration-resistant holding of the glass. To release the glass from the luminaire housing, turn it counterclockwise.

Replacement of the LED module ·Maintenance

The designation of the LED module is noted on a label in the luminaire.The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system. Unscrew glass from luminaire housing by turning it counterclockwise. Clean glass and luminaire regularly with solvent-free cleansers from dirt. Please follow the installation instructions for the LED module. Screw in glass by turning it clockwise as far as it will go. A broken glass must be replaced..

  • Spares
    • Spare glass 11 002 771 .0R G
    • LED power supply unit DEV-0391/850
    • LED module 3000 K LED-0570/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals