Assembly Instruction
Model No. | 4512750,4512751 |
---|---|
Rated Voltage | 220-240V~ |
Rated Frequency | 50Hz |
Rated Wattage | 300W |
**** Load Range | Incandescent:15W-300W |
LED/CFL:3W-200W
:3W-200W
:3W-100W
Dimming Method| Phase-cut
**** Working Environment| Temperature:-10℃ – 35℃
Humidity:10% R.H. – 90% R.H.
Model Size| 71mm×71mm×52mm(L×W×H)
WARNINGS AND CAUTIONS
- Risk of fire and electrical shock, the dimmer should be installed in accordance with appropriate electrical codes and regulations.
- The dimmer should be protected by a 16A maximum miniature circuit breaker.
- Turn power off at circuit breaker or fuse and test that power is off before installing.
- After install the dimmer, it is recommended to set the minimum brightness level to make bulbs turn on immediately.
- If you are unsure about any part of these instructions, consult a licensed electrician.
- To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance or a transformer-supplied appliance.
- Use with compatible dimmable LED, CFL bulbs, Incandescent or halogen bulbs only.
- When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED, CFL or incandescent. Using the same model of each bulb will enhance dimmer performance.
- This product complies to EN60669-2-1.
Splicing Design
Functional Specifications
Status Indicator
Indicator lights blue and flash: Enter to ZigBee mode connection.
Input and Output Terminals
N: Input terminal (Connect the neutral and live wire “N”)
L: Input terminal (Connect the live wire “L”)
Output terminal (Connect the bulbs)
P: Signal input terminal (Connect the self-reset switch-output terminal)
Short press: Within 0.5s
Long press: Over 0.5s
Continuous short press: Each interval of short press should within 1s
Push-button Rotary Switch
Turn on: Short press one time when in OFF.
Turn off: Short press one time when in ON.
Dimming:
a. Turn clockwise to increase the brightness.
b. Turn counterclockwise to decrease the brightness.
c. Long press to adjust the brightness when in ON status. Release and
long press again to change the direction of the dimming brightness. Continuous
short press two times when in ON/OFF can quickly turn to the full brightest.
Setting the ideal min brightness when in on status, continuous short press six
times and the lamp flash three times. Setting the ideal max brightness when in
on status, continuous short press eight times and the lamp flash three times.
Network mode: Continuous short press seven times when in ON status. then
the APP can connect the dimmer when the bulb flash once and the status
indicator turn blue and flash.
- If failed to connect, APP will exit the network mode after three minutes.
- During the network connection, the lamp may flicker if the light is in the brightest. After the network is successfully configured or the network is been withdrawn, the lamp will return to normal).
Continuous short press nine times when in on status and the lamp flash five time to clear the setting brightness(min or max).
Restore factory Settings: Continuous short press ten times when in ON and the lamp flash once.
Tools Needed To Install e Dimmer
Ø5mm Philips Screwdriver | Test pencil |
---|---|
Electrical Tape | Plier |
Cutter | Ruler |
Installation
WARNING: To avoid fire and electrical shock, TURN PFF POWER at circuit breaker or fuse and test that power is off before wiring.
Choose the connection of 5.3.1 or 5.3.2 to install the dimmer per your requirement. *The wire core cross-sectional area of the terminals is 0.75 mm² – 1.5mm²,stripping length is 9mm.
Typical wiring application
Live Wire
Way
Multi-way
NOTE:
(a) The dimmer should be connected to the electricity side of the load to
ensure normal work.
(b) The dimmer support to connect with multiple self-reset switches
(20pcs at most) to control the UP/DOWN and ON/OFF at the same time.
(c) Two or more dimmers should not be connected in parallel or series to
control the same load from two different locations.
Multipl self-switches control one dimmer wiring diagram
Oneself-reset switch control multiple dimmers wiring diagram
Multiples elf-reset switches control multiple dimmer swirling diagram
Neutral and Live Wire
Way
Multi-way
NOTE:
(a) The dimmer should be connected to the electricity side of the load to
ensure normal work.
(b) The dimmer support to connect with multiple self-reset switches
(20pcs at most) to control the UP/DOWN and ON/OFF at the same time.
(c) Two or more dimmers should not be connected in parallel or series to
control the same load from two different locations.
Multipl self-reset switches control one dimmer wiring diagram
One self-reset switch control multiple dimmers wiring diagram
Multiple self-reset switches control multi-way dimmers wiring diagram
Installing dimmer
Divide the dimmer into two parts. (Operation Component, Panel and Drive
Component)
Carefully position all wires inside the wall-box, leaving enough space to
insert the dimmer housing.
Put the Drive Component inside the wall-box and align at the screw holes(①②)
Tighten the screws(①②) to let the Drive Component stick to the Junction Box.
Install the Operation Component to the Fixing Panel and put them together to
the Drive Component.
User Instructions
Function Instructions
Table 1 1-way application function
Function | Dimmer Operation Way | Dimmer Operation | App Operation |
---|---|---|---|
**** Network Mode | **** Continuous short press the push-button rotary | ||
dimmer seven times | **** √ | **** × | |
ON/OFF | Short press the push-button rotary switch one time | **** √ | **** √ |
Dimming | Turn the push-button rotary switch | √ | √ |
Quickly turn to the full brightest | Continuous short press the push-button | ||
rotary switch two times | **** √ | **** √ | |
**** Set the min brightness | **** Continuous short press the push-button | ||
rotary dimmer six times | **** √ | **** × | |
Set the max brightness | Continuous short press the push-button rotary dimmer | ||
eight times | **** √ | × | |
Clear the setting(min roman ) brightness | Continuous short press the push- | ||
button rotary dimmer nine times | **** √ | × | |
Restore factory Settings | Continuous short press the push-button rotary switch | ||
ten times | **** √ | × | |
Schedule on/off | NO | × | √ |
Share device | NO | × | √ |
Group control | NO | × | √ |
Function | Dimmer Operation Way | Dimmer Operation | Self-reset Switch Operation |
App Operation
---|---|---|---|---
**** Network Mode| Continuous short press thepush-button rotary
dimmer seven times| √| ×| ×
ON/OFF| Short press the push-button rotaryswitch one time| √| √| √
Dimming| Turn the push-button rotary switch| √| √| √
Quickly turn to the full brightest| Continuous short press thepush-button
rotary switch two times| √| √| √
Set the min brightness| Continuous short press the push-button
rotary dimmer six times| √| ×| ×
Set the max brightness| Continuous short press the push-button rotary dimmer
eighttimes| √| ×| ×
Clear the setting(min or max ) brightness| Continuous short press thepush-
button rotary dimmer nine times| √| ×| ×
Restore factory Settings| Continuous short press the push-button rotary switch
ten times| √| ×| ×
Schedule on/off| NO| ×| ×| √
Share device| NO| ×| ×| √
Group control| NO| ×| ×| √
Priority
The operation of self-reset switch could stop the operation of APP, when at
the operation of self-reset switch, APP operation could not work
Troubleshooting
Problems | Possible Cause | Solution |
---|---|---|
Lights flickering | Lamp has a bad connection. | Reconnect and fix the wires. |
The brightness of the lamp varies | One dimmer been connected to multiple types | |
bulbs, incur interference and cause flicker. | Change bulbs to same type. | |
LED and CFL flickers at lowed of dimming range. | Load compatibility is not | |
good. | Turn up lamp minimum brightness properly. | |
Lights does not turn on | Circuit breaker has tripped. | Turn power on |
Fuse burn out | Change fuse | |
Lamp burned out | Change lamp | |
Lamp neutral connectionism not wired | Reconnect the lamp neutral | |
Lights out of control | Abnormal | Restart the power switch |