BEGA 66 105 Pendant Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 66 105 Pendant Luminaire

Product Information:

Product Name Pendelleuchte Pendant luminaire Suspension
Application Pendant luminaire with unshielded light for mounting in

arcades, galleries, and passageways. When installed in exterior
applications, the luminaire must be protected from constant
pendulum movement due to wind.
Safety| The installation and operation of this luminaire are subject to
national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Lamp| Luminaire with screw base E27 Lamp output max. 150W. This
product contains a light source of energy efficiency class E.
Luminaire Efficiency| 83%

Product Usage Instructions

  1. Insert lamps into the luminaire.
  2. Insert opal glass sphere into the holder plate and adjust it centrically.
  3. Tighten the screws at the holder plate evenly.
  4. Make sure that the gasket is in the correct position.

Pendant luminaire

Instructions for use

Application

  • Pendant luminaire with unshielded light for mounting in arcades, galleries and passageways.
  • When installed in exterior applications, the luminaire must be protected from constant pendulum movement due to wind.

Product Description

  • Luminaire made of aluminium alloy,aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour white
  • White synthetic sphere
  • Silicone gasket
  • 4 drilled holes with thread M4 to which tension cables preventing pendulum movement can be fixed
  • Mounting plate with 2 fixing
  • holes ø 6 mm · 70 mm spacing
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm
  • Cable pendant H05RRD3-F 3 G 1@ with 2 steel cords · Colour black
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • Lampholder E 27
  • Safety class I
  • Protection class IP 64
  • Dust-tight and protection against splash water Impact strength IK05
  • Protection against mechanical impacts < 0.7 joule
  • – Conformity mark
  • Weight: 3.8 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Installation

For mains supply connection open the mounting box. When luminaire is mounted in assembly halls please see that steel cord 1 is closely and under tension fixed to a non-inflammable building component – please see sketch. Fix end of steel cord on the back of mounting plate 2 with hexagon socket head screw M5. Lead mains supply cable through the cable entry of the mounting plate. Fix mounting plate with enclosed or any other suitable fixing material onto the mounting surface. It is absolutely essential to use the enclosed gaskets. Make earth conductor connection and electrical connection.
Make earth conductor connection between mounting box and mounting plate Plug in plug connection up to the stop. Make sure that the gasket is positiooned correctly. Bolt mounting box firmly together with mounting plate.

To shorten the cable pendant

  • The cable must only be shortened within the mounting box. Disconnect mains supply cable from plug connection and earth conductor terminal. Loosen locking screws – hexagon socket head screws M4 – for suspension cord. Pull suspension cords out of lock holes.
  • Screw off round nut 3 and pull cable with gasket out of screw connection. Shorten cable to the desired length. Insert pressure pressure disk into the round nut and press gasket into the round nut. Grease connecting cable somewhat and lead it through round nut and gasket. Tighten round nut as far as it will go and screw it together with the mounting box. Strip lines and pull suspension cords thightly into the lock holes at the cord holder.Tighten locking screws M4 firmly. Shorten steel cords with excess length, protect with end sleeves.

Lamp

  • Luminaire with screw base E 27
  • Lamp output max. 150 W
  • This product contains light source of energy efficiency class E

Supplied lamp

  • BEGA LED lamp 13 590
  • LED Retrofit 12 W · 1400 lm · 3000 K
    Luminaire efficiency: 83%

Additional BEGA LED lamps are available for this luminaire:

  • 13 584 LED 7 W · 805 lm · 3000 K
  • 13 586 LED 7 W · 805 lm · 3000 K dimmable
  • 13 588 LED 8 W · 1055 lm · 3000 K
  • 13 592 LED 12 W · 1400 lm · 3000 K  dimmable

Detailed technical and lighting data for the lamps can be found in the data sheets on our website.

To insert lamp

Insert lamps.
Insert opal glass sphere into holder plate and adjust centrically. Tighten screws at holder plate evenly.
Make sure that the gasket is in correct position.

Relamping · Maintenance

  • Open the luminaire. Undo screws at the glass holder plate so that the collar of the sphere opening is exposed.
  • Take the plastic sphere out of the holder plate. Change the lamp. Check the gasket and replace, if necessary.
  • Install the plastic sphere and adjust centrically. Tighten screws at the holder plate.

Cleaning · Maintenance

  • Clean dirt and debris from the luminaire regularly with a clean, soft, lint-free cloth that is kept damp throughout the cleaning.
  • If possible, please use water for this, adding a little commercial dishwashing detergent.
  • For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.
  • Cleaning agents containing solvents and high-pressure cleaners are unsuitable for cleaning and maintenance.

Spares

  • LED lamp 3000K 13 590
  • White synthetic sphere 15 000 149 .6
  • Lampholder 63 000 105
  • Gasket glass 83 000 417
  • Gasket mounting box 83 001 903

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com