51144.6 Indoor Wall Luminaire
Instruction Manual
51144.6 Indoor Wall Luminaire
Wall luminaire for indoor use
Instructions for use
Application
Wall luminaire · indoor luminaire with velvet white luminaire housing and
inside hue. The light emits upwards and downwards.
Product description
Wall luminaire “STUDIO LINE” Aluminium luminaire housing, finish Colour velvet
white inside hue matt copper Light-diffusing synthetic LED cover 2 elongated
fixing holes Width 4.5 mm · 90 x 38 mm spacing 1 cable entry for through-
wiring for mains cable
Connecting terminals 2.5@ Earth conductor terminal LED power supply unit
220-240 V x 0/50-60 Hz DC 176-275 V DALI-controllable Basic insulation is
provided between the mains and control cables BEGA Thermal Control ®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire Safety class I Conformity mark Weight:
1.2 kg This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or nstallation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 24.6 W |
---|---|
Luminaire connected wattage | 28 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 25 °C |
51 144.6 K3
Module designation | 2x LED-0986/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 3370 lm |
Luminaire luminous flux | 1120 lm |
Luminaire luminous efficiency | 40 lm / W |
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the hexagon socket head screws (wrench size 2.5 mm) and lift luminaire
housing. Unplug the earth conductor connection (plug contact). Pass the power
connecting cable through the cable entry in the mounting plate. Fasten the
mounting plate with the supplied fastening material or other suitable
fastening material to the installation surface.
Note position of application of the mounting plate “arrow down”. Establish the
earth conductor connection on the earthing screw (1) of the mounting plate.
Push silicone sleeves over the lines.
Make the electrical connection to the terminals.
Observe the correct configuration of the connecting cable. Connect the live
conductor to the brown wire (L) and the neutral conductor to the blue wire
(N).The two connecting terminals marked DA, DA are provided for digital
control purposes. If these terminals are not assigned, the luminaire will work
with full light output.
Make earth conductor connection between luminaire housing and mounting plate
(plug contact).
Place connecting terminals inside the luminaire housing.
Note position of application of the luminaire“arrow down”. Install
luminaire housing over mounting plate and tighten hexagon socket head screws
(wrench size 2.5 mm) evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module Replacing the power supply unit
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supplyUnscrew the hexagon socket screws
(SW 2.5) underneath and lift off the luminaire housing.
Remove the wires on the luminaire side from the terminals marked (L), (N), DA
DA.
Disconnect the earth conductor connection with the mounting plate (plug
contact).
Insert hex wrench (SW 2–2.5) in the bore holes in the diffuser lenses. Release
the diffuser lenses from their magnetic holders by rotating them slightly and
carefully pull them out of
the luminaire housing together with the hex wrench.
Unscrew the two nuts (M 2.5) with serrated washers in the connection
compartment of the luminaire housing, and remove the die-cast housing with LED
modules and power supply unit from the luminaire housing.
Remove the LED module. Install the replacement LED module. Please follow the
installation instructions for the LED module.
Replace defective LED power supply unit.
Install in reverse order.
Spares
LED power supply unit | DEV-0402/700i |
---|---|
LED module 3000 K | LED-0986/930 |
Diffuser disk | 75 004 704 |