BEGA 84089 In-ground Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 84089 In-ground Luminaire

Product Information

Product Name In-ground Luminaire
Model Number 84 089
IP Rating IP67
Light Distribution Symmetrical, directed upwards
Application Accentuated illumination of private gardens
Installation Flush installation in soil, lawn, or gravel; resistant to foot

traffic
Vehicle Resistance| Must not be overrun by vehicles
Overvoltage Protection| The electronic components are protected against overvoltage;
additional protection is recommended using separate overvoltage
protection components
Lamp Module Wattage| 6.1 W
Luminaire Wattage| 7.2 W
Color Temperature| 3000 K
Colour Rendering Index (CRI)| >80
Module Luminous Flux| 945 lm
Luminaire Luminous Flux| 466 lm
Luminaire Luminous Efficiency| 64.7 lm/W

Product Usage Instructions

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Please avoid touching the light output opening of the LED directly during installation or relamping.

Note: Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.

Accessories

  • 70 730 Distribution box for installation in soil with 7 cable entries and connection terminals (5×4@)

Spare Parts

  • Spare glass: 14 001 359
  • LED power supply unit: DEV-0304/350
  • LED module 3000 K: LED-0392/830
  • Reflector
  • Gasket glass: 83 001 850

DIMENSIONS

BEGA-84089-In-ground-Luminaire-FIG-1

Instructions for use

Application

  • In-ground luminaire with symmetrical light distribution directed upwards for accentuated illumination of private gardens.
  • Luminaire resistant to foot traffic for flush installation in soil, lawn, or gravel.
  • Luminaire must not be overrun by vehicles.

Product Description

  • Luminaire housing made of glass-fiber-reinforced synthetic
  • The cover frame is made of stainless steel, steel grade number 1.4301
  • Clear safety glass
  • The reflector surface is made of pure aluminum
  • 1,8 m water-resistant connecting cable 07RN8-F 3 G 1@ with implemented water stopper and 1.2 m PVC cable conduit
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 67
  • Dust-tight and protection against temporary immersion
  • Pressure load 150 kg (~1,500 N)
  • Impact strength IK09
  • Protection against mechanical impacts < 10 joule
  •  – Safety mark
  •  – Conformity mark
  • Weight: 1.6 kg
  • This product contains light sources of energy efficiency class(es) D

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Module connected wattage 6.1 W
  • Luminaire connected wattage 7.2 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C
  • When installed in heat-insulating
  • material ta max = 25 °C

84 089 K3

  • Module designation LED-0392/830
  • Color temperature 3000 K
  • Color rendering index CRI > 80
  • Module luminous flux 945 lm
  • Luminaire luminous flux 466 lm
  • Luminaire luminous efficiency 64,7 lm / W

Installation

  • Sufficient drainage (e. g. gravel, stone chippings) must be provided under the luminaire.
  • 0.3 m of cable should be left under the luminaire housing so that the luminaire could be removed during maintenance work.
  • Insert the luminaire flush into the soil surface.
  • To protect the luminaire connecting the cable from damage push the enclosed cable conduit over the cable.
  • The electrical connection at the luminaire connecting cable must be carried out on-site according to the protection class and safety class.
  • We recommend using a distribution box 70 730 or 71 053.

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Cleaning · Maintenance

  • After installation, the luminaire should first be cleaned.
  • Building dust, residues from contact adhesives, paint splashes, and rust film must be completely removed.
  • Never use high-pressure cleaners and cleaning implements made of normal steel, steel brushes, or steel wool because they cause extraneous rust to form.
  • When using stainless steel cleaners, please read the directions carefully.
  • Cleaning agents containing hydrochloric acid and chlorides should never be used.
  • We recommend cleaning the luminaires regularly.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.

Disconnect the system.

  • Lift the luminaire out of the ground surface and place it with the glass side facing downwards onto an even and clean underlay.
  • Undo hexagon nuts and lift luminaire housing.
  • LED modules can be replaced now.
  • Please follow the installation instructions for the LED module.
  • Check all hexagon nuts and threads thoroughly and grease them.
  • Check the gasket and replace, it if necessary.
  • A broken glass must be replaced.
  • Insert reflector.
  • Insert glass with the stepped side turned upward into the luminaire housing.
  • Make sure that the gasket is positioned correctly.
  • Place the cover frame onto the glass step and tighten firmly nuts crosswise.
  • Torque = 2 Nm.

Accessories

  • 70 730 Distribution box for installation in soil with 7 cable entries Connection terminals 5 x 4@
  • A separate instructions for use can be provided upon request.

Spares

  • Spare glass 14 001 359
  • LED power supply unit DEV-0304/350
  • LED module 3000 K LED-0392/830
  • Reflector 76 001 963
  • Gasket glass 83 001 850

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals