BEGA 50652 Ceiling and Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 50652 Ceiling and Wall Luminaire
Product Information
Product Description| Metal housing, finish Colour white
Hand-blown opal glass, satin matt, with sliding-bolt closure
---|---
Distance Apart| 240 mm
Plug Connection| Yes
Earth Conductor Connection| Yes
Safety Class| I
Protection Class| IP 44 (Protected against granular foreign bodies & splash
water)
Impact Strength| IK06
Weight| 3.8 kg
Product Usage Instructions
Safety:
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning mayonly be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage Protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. Toachieve additional protection against transients and other issues, it is recommended to use separate overvoltage protection components.
Installation:
- Disassemble the LED module.
- Loosen the LED-connection and earth connection (plug connection).
- Dismantle the mains supply cable maximum of 80 mm.
- Lead the mains supply cable through the cable entry into the luminaire housing.
- Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting.
Dimension
Ceiling and wall luminaire for indoor use
Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.
Product description
- Metal housing, finish Colour white
- Hand-blown opal glass, satin matt, with sliding-bolt closure
- 2 mounting holes ø 5.5 mm
- Distance apart 240 mm
- 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
- Connecting terminal 2.5@
- with plug connection
- Earth conductor connection
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 170-280 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Protection class IP 44
- Protected against granular foreign bodies ≥ 1 mm and splash water
- Impact strength IK06
- Protection against mechanical
- impacts < 1 joule
- – Safety mark
- – Conformity mark
- Weight: 3.8 kg
- This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp
-
Module connected wattage 25.3 W
-
Luminaire connected wattage 29 W
-
Rated temperature ta = 25 °C
-
Ambient temperature ta max = 40 °C
-
50 652 K3
-
Module designation LED-0570/930
-
Colour temperature 3000 K
-
Colour rendering index CRI > 90
-
Module luminous flux 3615 lm
-
Luminaire luminous flux * 2100 lm
-
Luminaire luminous efficiency * 72,4 lm / W
-
preliminary data
Installation
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Disassemble LED module.
- Loosen LED-connection and earth connection (plug connection).
- Dismantle the mains supply cable max. 80 mm.
- Lead mains supply cable through the cable entry into the luminaire housing.
- Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
- It is imperative to use the enclosed gaskets.
- Make earth conductor connection.
- Push silicone sleeves over the lines and make electrical connection.
- Make earth connection between LED module and luminaire housing (plug connection).
- Push LED-plugs into couplers as far as it will go.
- Assemble LED module.
- Tighten the screws evenly (max. 0,8 Nm).
- Please observe that the LED module is not damaged mechanically.
- Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn the glass clockwise up to the stop.
- Place glass to the luminaire housing and observe that the holding springbolts fit into the notches of the glass.
- Turn the glass clockwise until it is locked.
- Thus, you reach a safe and vibration-resistant holding of the glass.
- To release the glass from the luminaire housing, turn it counter-clockwise.
Maintenance
Replacement of the LED module · Maintenance
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system.
- Unscrew glass from luminaire housing by turning it counter-clockwise.
- Clean glass and luminaire regularly with solvent-free cleansers from dirt.
- Please follow the installation instructions for the LED module.
- Screw in glass by turning it clockwise as far as it will go.
- A broken glass must be replaced.
Spares
- Spare glass 11 002 771 .0R G
- LED power supply unit DEV-0291/850
- LED module 3000 K LED-0570/930
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com