BEGA 77028 In Ground Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 77028 In Ground Luminaire

Product Information

The product is a recessed location luminaire designed for recessed mounting in compacted surfaces, paths, and open areas. It can also be used as a drive-over luminaire for vehicles with pneumatic tires. However, it should not be installed in road lanes where it may be exposed to horizontal strain caused by braking, acceleration, and change of direction.

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. For additional protection against transients and other factors, separate overvoltage protection components are recommended. Prior to installation, it is important to provide a proper foundation capable of accepting a maximum pressure load of 2,000 kg (~20 kN). The pressure load is transferred to the foundation through the luminaire housing, so it must be firmly concreted in on a firm subgrade for stability.

Product Usage Instructions

  1. Choose the appropriate module designation based on the desired color temperature, color rendering index, module luminous flux, luminaire luminous flux, and luminaire luminous efficiency.
  2. Ensure that a proper foundation capable of accepting a maximum pressure load of 2,000 kg (~20 kN) is provided by the customer.
  3. Install the luminaire in a recessed location in compacted surfaces, paths, or open areas.
  4. If using as a drive-over luminaire for vehicles with pneumatic tires, ensure that it is not installed in road lanes exposed to horizontal strain due to braking, acceleration, and change of direction.
  5. If additional protection against overvoltage or transients is desired, consider installing separate overvoltage protection components.
  6. Firmly concrete the luminaire housing into the foundation on a firm subgrade to ensure stability.
  7. Do not remove the desiccant bag from the luminaire housing as it is needed to remove residual moisture.

Dimensions

Instructions for use

Application

  • Recessed location luminaire for recessed mounting in compacted surfaces, paths and open areas.
  • Drive-over luminaire for vehicles with pneumatic tyres.

Please note: Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.

Product Description

  • Cover ring Luminaire housing made of stainless steel and cast stainless steel
  • Steel grade number 1.4301
  • Safety glass, white
  • Reflector made of pure anodised aluminium 2 mounting holes ø 5 mm
  • Distance apart 120 mm
  • 1,8 m water-resistant connecting cable
  • 05RN8-F 3 G 1@ with implemented water stopper and 1.2 m PVC cable conduit
  • BEGA Ultimate Driver®
  • LED power supply unit: 220-240 V x 0/50-60 Hz
    • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class: I
  • Protection class: IP 68 10 m
  • Dust-tight and water pressure tight
  • Maximum submersion depth 10 m
  • Not suitable for permanent operation under water
  • Pressure load 2,000 kg (~20 kN)
  • Impact strength: IK10
  • Protection against mechanical impacts < 20 joule
  • Maximum surface temperature 20 °C (measured according to EN 60598 of ta 15 °C)
  • : Safety mark
  • CE:  Conformity mark
  • Weight: 1.6 kg
  • This product contains light sources of energy efficiency class(es) C, D

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Notice prior to installation

  • To accept the maximum pressure load of 2,000 kg (~20 kN) a proper foundation must be provided by the customer.
  • The pressure load is transferred to the foundation by this luminaire housing provided at site.
  • The foundation must be carried out on firm subgrade.
  • In order to obtain a firm stableness, the luminaire housing must be firmly concreted in.

Installation

  • Position luminaire housing on the foundation (as described above) and fix it with enclosed or any other suitable fixing material.
  • The electrical connection at the luminaire connecting cable must be carried out on site according to the protection class and safety class.
  • We recommend to use a distribution box 70 730-.
  • To protect the luminaire connecting cable from damage push the enclosed cable conduit over the cable.
  • After finishing the ground works remove protection film from the luminaire cover.
  • Tighten the screws in the trim ring evenly crosswise.
  • Torque = 3 Nm.

Maintenance

Cleaning/ Maintenance

  • After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed.
  • Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form.
  • When using stainless steel cleaners, please read the directions carefully.
  • Cleaning agents containing hydrochloric acid and chlorides should never be used.
  • We recommend cleaning the luminaires regularly.

Lamp

  • Module connected wattage: 2 W
  • Luminaire connected wattage:  2.7 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 50 °C
  • When installed in heat-insulating material: ta max = 35 °C

77 028 K27

  • Module designation: LED-0305/827
  • Colour temperature: 2700 K
  • Colour rendering index: CRI > 80
  • Module luminous flux:  335 lm
  • Luminaire luminous flux: 83 lm
  • Luminaire luminous efficiency: 30,7 lm / W

77 028 K3

  • Module designation: LED-0305/830
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 80
  • Module luminous flux: 345 lm
  • Luminaire luminous flux: 86 lm
  • Luminaire luminous efficiency: 31,9 lm / W

77 028 K4

  • Module designation: LED-0305/840
  • Colour temperature: 4000 K
  • Colour rendering index: CRI > 80
  • Module luminous flux: 350 lm
  • Luminaire luminous flux: 87 lm
  • Luminaire luminous efficiency: 32,2 lm / W

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the electrical installation.
  • Clean dirt and deposits from key openings of screw head. Do not use a high pressure cleaner. Open the luminaire and clean. Use only solvent-free cleansers. Dismantle the LED-board unit and disconnect the connecting cable at the terminal of the LED board unit.
  • Make electrical connection of the new LED board unit.
  • Fix LED board unit in the luminaire housing.
  • Check all screws and threads thoroughly and grease. Check the gasket and replace, if necessary. The luminaire housing must be completely clean and absolutely dry. Close the luminaire. Torque = 3 Nm. Chemicals which have a corroding effect must not affect the luminaire housing.

Accessories

70 730 Distribution box

  • The distribution box is meant for installation in the soil and allows a junction from the supply cable to the luminaire and through-wiring to the next luminaire.
  • After the electrical connection the distribution box is filled up with gel and closed.

Spares

  • Spare glass: 14 000 920
  • LED power supply unit: DEV-0292/350
  • LED module 2700 K: LED-0305/827
  • LED module 3000 K: LED-0305/830
  • LED module 4000 K: LED-0305/840
  • Reflector: 76 001 143
  • Gasket: 83 001 786

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals