signify SolarForm Gen2 Solar Street Lighting Instruction Manual
- June 12, 2024
- signify
Table of Contents
signify SolarForm Gen2 Solar Street Lighting
Product Information:
The product is a luminaire, designed to provide lighting. It is important to carefully read and understand all warnings and instructions provided in the user manual before installation, operation, service, or maintenance. Failure to do so can result in death, personal injury, and property damage. The installation, service, and maintenance of the luminaires should be performed by a qualified professional who is familiar with the product’s construction, operation, and any hazards involved. The product should be installed in accordance with federal, state, and local laws, regulations, and electrical codes.
Product Usage Instructions:
-
Before attempting any installation, service, or maintenance, disconnect or turn off the power to the luminaire. Verify that the supply voltage is correct by referencing the information on the luminaire label.
-
Make all electrical and ground connections in accordance with the National Electrical Code (NEC) and any other applicable laws, regulations, or codes. Ensure that all wiring connections are capped with UL-approved wire connectors.
-
Keep combustible materials away from the LED/lamp and lens of the luminaire. Avoid operating the luminaire in close proximity to persons, combustible materials, or substances affected by heat or drying.
-
Wear gloves and safety glasses at all times when handling the luminaire during installation, servicing, or maintenance. Avoid direct eye exposure to the light source while it is on.
-
Allow the LED/lamp and lens to cool before handling. Do not touch the enclosure or light source. Ensure that you do not exceed the maximum wattage marked on the luminaire label.
-
Follow all manufacturer’s warnings, recommendations, instructions, and restrictions for driver type, burning position, mounting locations, and replacement.
-
Never connect luminaires and/or components under load with the supply voltage turned on. Do not mount or support the luminaires in a manner that can cut the outer jacket or damage wire insulation. Ensure proper fixture ventilation by allowing some
volume of airspace around the luminaire. Avoid covering the luminaire with insulation, foam, or other materials. -
In case of any issues or the need for service, stop using the luminaire immediately and contact the Customer Care Call Center at 800-555-0050.
-
Always read the luminaire’s complete installation instructions prior to installation for any additional luminaire-specific warnings. For HID or Fluorescent luminaires, regular re-lamping is required to keep the luminaire operating within safe limits.
INSTALLATION
WARNINGS AND INSTRUCTIONS FOR LUMINAIRES
IMPORTANT: FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR ENTIRETY PRIOR TO INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. If you do not understand these warnings and instructions, or if additional information is desired, please contact the Customer Care Call Center at 800‐555‐0050.
- Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all federal, state and local laws, regulations and electrical codes. This professional should be familiar with the construction and operation of this product and any hazards involved. If not qualified, do not attempt installation, service or maintenance.
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please read all warnings and instructions included with the luminaire, on the luminaire’s packaging and affixed to the luminaire itself.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaire’s construction and operation and any hazards involved.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
- Disconnect or turn off power before attempting any installation, service or maintenance.
- Verify that supply voltage is correct by referencing the luminaire label information.
- Make all electrical and ground connections in accordance with the National Electrical Code (NEC) and any other applicable laws, regulations or codes.
- All wiring connections should be capped with UL‐approved wire connectors.
WARNING
RISK OF FIRE OR PERSONAL INJURY
- Keep combustible materials away from LED/lamp & lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
WARNING
RISK OF PERSONAL INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
- Allow LED/lamp & lens to cool before handling.
- Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations, instructions and restrictions for driver type, burning position, mounting locations and replacement.
CAUTION
RISK OF PRODUCT DAMAGE
-
Never connect luminaires and/or components under load with supply voltage turned on.
-
Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
-
Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insulation, foam or other material that will prevent convection or conduction cooling.
-
Do not exceed luminaire maximum ambient temperature.
-
Do not modify the luminaire.
-
Only use luminaire in its intended application and location.
-
LED products are polarity sensitive. Ensure proper polarity before installation.
-
Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.
-
Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.
Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and contact the Customer Care Call Center at 800‐555‐0050. -
Always read the luminaire’s complete installation instructions prior to installation for any additional luminaire specific warnings.
-
In the case of HID or Fluorescent luminaires, regular re‐lamping is required to keep luminaire operating within safe limits
-
Do not install damaged product. Handling and installing damaged products can potentially increase the risks mentioned. In case of damage and/or missing parts upon arrival of the luminaire, please contact the Customer Care Call Center at 800‐555‐0050.
-
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to the Customer Care Call Center at 800‐555‐0050.
-
Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to follow any of these instructions could void luminaire warranties.
Luminaire Maintenance
- Regular luminaire maintenance programs are recommended.
- It is recommended to clean the outside of the luminaire and the refractor/lens.
- Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user.
- If clean water is not sufficient for cleaning, use a neutral, synthetic, non‐scratching and non‐abrasive cleaning substance.
- Never use alkaline and/or acetous cleaning substances.
- Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water.
- Signify recommends using a cleaning solution that has a PH between 5 and 8.
- Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.
Precautions & Warnings:
- Turn OFF power switch when opening the luminaire for any reason. Luminaire must be removed from pole during any servicing.
- External or otherwise artificially concentrated sunlight shall not be directed onto the front or back face of the PV module.
- Carefully re-install all seals and gaskets when servicing the luminaire.
- This luminaire will not operate below 0 degree ambient.
- Maximum installation height is 16 ft. (5m).
- Before installation check the luminaire by pressing the ON/OFF power switch and make sure that it is glowing.
- After three months of manufacturing it is necessary to check the glowing of the luminaire, if it is not working then contact customer care.
- The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
- Torque of Pole mounting M8X45 bolts and Angle adjustment M8X30 bolts should be 6 lbs-ft (8 Nm).
REQUIRED TOOLS: M8 SOCKET/OPEN –END WRENCH
HARDWARE SUPPLIED: (2) M8X45 BOLTS, (2) M8 NUTS, (2) M8X30 BOLTS W/PLAIN
& SPRING WASHER
SolarForm Dimensions
REQUIRED TOOLS: M8 SOCKET/OPEN –END WRENCH
HARDWARE SUPPLIED: (2) M8X45 BOLTS, (2) M8 NUTS, (2) M8X30 BOLTS W/PLAIN
& SPRING WASHER
© 2019 Signify Holding. All rights reserved. This document may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. All trademarks are owned by Signify Holding or their respective owners.
Signify North America Corporation 200 Franklin Square Drive, Somerset. NJ 08873 Telephone 855-486-2216
Signify Canada Ltd. 281 Hillmount Road, Markham, ON. Canada L6C 2S3 Telephone 800-668-9008
References
- U.S. Environmental Protection Agency | US EPA
- Outdoor architectural solutions lighting | Gardco | Signify
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>