STAUBLI MA213-11 6 GHz Coaxial Unit Instruction Manual

October 30, 2023
STAUBLI

MA213-11 (jp_en)
Assembly instructions

Safety instructions

The products may be assembled and installed by electrically skilled or instructed persons duly observing all applicable safety regulations.
Stäubli Electrical Connectors (Stäubli) does not accept any liability in the event of failure to observe these warnings.
Use only the components and tools specified by Stäubli. In case of self- assembly, do not deviate from the preparation and assembly instructions as stated herein, otherwise Stäubli cannot give any  guarantee asto safety or conformity with the technical data. Do not modify the product in any way.
Connectors not originally manufactured by Stäubli which can be mated with Stäubli elements and in some cases are even described as ”Stäubli-compatible” by certain manufacturers do not conform to the requirements for safe electrical connection with long-term stability, and for safety reasons must not be plugged together with Stäubli elements. Stäubli therefore does not accept any liability for any damages resulting from mating such connectors (i.e. lacking Stäubli approval) with Stäubli elements.
Installation, electrotechnical expertise
The products may be assembled and installed by electrically skilled or instructed persons duly observing all applicable safety regulations.
Caution, risk of electric shock
(IEC 60417-6042)

Work in a de-energized state
Follow the five safety rules, when working on electrical installations.
After the  respectiveelectrical installations  have been identified, the following five essential requirements shall be undertaken in the specified order unless there are essential reasons for doing otherwise:
– disconnect completely;
– secure against re-connection;
– verify absence of operating voltage;
– carry out earthing and short-circuiting;
– provide protection against adjacent live parts.
Any person engaged in this work activity shall be electrically skilled or instructed, or shall be supervised by such a person. Source: EN 50110-1:2013
Protection against electric shock shall be checked in the end-use applications too.

Caution
(ISO 7000-0434B)

Each time the connector is used, it should previously be inspected for external defects (particularly the insulation). If there  are any doubts as to its safety, a specialist must be consulted orthe connector must be replaced.
The plug connectors are watertight in accordance with the product specific IP protection class.
Unmated plug connectors must be protected from moisture and dirt. The male and female parts must not be plugged together when soiled.

Useful hint or tip

For further technical data please see the product catalog.

Product overview

CRIMP VERSION

No Order No. Type
33.063 CT-S-COAX-RG316/U
33.0631 CT-S-COAX-RG58

Tools required
(ill. 1)
Crimping pliers CT-M-CZ,
Order No. 33.3800
Note: Operating instructions MA079
www.staubli.com/electrical
(ill. 2)
Locator MES-CZ-CT0,6-COAX-RG,
Order no. 18.3808
(ill. 3)
Insulation stripper.
Use a suitable insulation stripper for RG58, RG316/U, RG174, RG188
(ill. 4)
Screwdriver size 0
Open-end wrench crimp: A/F 9, A/F 10
Open-end wrench SMA: A/F 8, A/F 11
(ill. 5)
Side cutting pliers

CRIMP VERSION

Cable preparation
**** Note: Pin and socket side assembly procedure is identical!

(ill. 6)
First place single parts (nut (8), ring (7) and rubber (6)) on the cable as shown. The rubber is on the side closest to the cable end.

(ill. 7)
Strip the insulator (outer sheath) to 10 0/-0.2 (mm).This applies to all cable types.
Attention
Do not damage the shielding braid Shielding braid preparation

(ill. 8)
Fan out shielding braid. Move rubber (6) forward until it is flush with the sheath. Place shielding braid around the rubber.
Inner conductor preparation

(ill. 9)
Strip the dielectric insulator to 7 0/-0.2 (mm).
Shielding sleeve assembly

(ill. 10)
Push the sleeve (5) over the dielectric insulator until it touches the shielding braid.
Inner conductor termination

(ill. 11)
First push the spacer (4) over the inner conductor until the dielectricum insulator. Then place the pin or socket (3) over the inner conductor and push back until it reaches the ring.
Finally, use the crimping pliers CT-MC-Z (33.3380) to crimp according to MA079 operating instructions.
Use locator MES-CZ-CT0,6-COAX-RG (Order no. 18.3808) for correct crimp positioning.For RG58 cables adjust crimping pliers position to “SEL No. 4”, and “SEL No.2” for RG174, RG188, RG316/U cables.

Note (ill. 12):
The conductor must be visible in the sight hole, before and after the crimping process.
Assembly of pin/socket insulator and pin/socket

(ill. 13)
Use the side cutting pliers to cut off any braid wires that project beyond the sleeve. To prevent contact between braid wires and inner conductor, braid wires must not project beyond the sleeve.

(ill. 14)
Push the insulator (2) over the pin or socket (3) and onto the spacer (4).

(ill. 15)
Place the pin/socket (1) over the insulator (2), and screw it onto the nut (8). When screwed, a maximum 1 mm gap is permited between the pin/socket and nut.
Assembly of crimped pin and socket contacts in carrier

(ill. 16)
Insert contacts and lock with the retaining clip.
SMA VERSION
Assembly with SMA termination

Screw your SMA connector onto the CombiTac SMA contact.
Max. tightening torque 1 Nm.
Assembly of SMA pin and socket contacts in carrier

(ill. 19)
Insert contacts and lock with the retaining clip.
The hexagon prevents the SMA contacts from rotating.
Checking the assembly (Crimp and SMA version)

(ill. 20)

  • Contact socket and carrier surface must be aligned (flush)
  • Contact pins project 10.4 mm from the carrier surface
  • Ensure retaining clips on both sides are locked.
    Note: Use screwdriver to pull out and remove retaining clip.
    Note: Care should be taken not to pull directly on the cable (cable strain)

/Producer: Stäubli Electrical Connectors AG
Stockbrunnenrain 8
4123 Allschwil/Switzerland
Tel. +41 61 306 55 55
Fax +41 61 306 55 56
mail [email protected]
www.staubli.com/electrical
© by Stäubli Electrical Connectors AG, Switzerland – MA213-11 – 05.2017, Index a, Marketing Communications – Änderungen vorbehalten / Subject to alterations