SuperFish Koi-Flow 20 Pond Air Pump User Manual

June 6, 2024
SuperFish

SuperFish Koi-Flow 20 Pond Air Pump

General instructions

Read this manual carefully before using this device. Keep this manual for future reference.

Meaning of symbols

The following warning symbols and/or signal words are used in this manual:
DANGER!
This means an imminent danger due to electric current. Failure to follow the safety instructions can result in serious or fatal injury and/or serious damage to the product or environment.
WARNING!
This means a dangerous situation. Failure to follow the safety instructions can result in moderate or minor personal injury and/or damage to the product or environment.
NOTICE!
This means caution, useful information or advice.
Meaning of the symbols on the device itself:
This device complies with all applicable EU standards.
This device may not be disposed of with normal household waste but must be collected separately for recycling.

Safety

Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.

  • ****This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.

  • Ensure the voltage shown on the label matches the mains supply voltage.

  • This device must be connected to a socket which is earthed.

  • Protect the device against moisture and flooding and place the device at least 2 metres away from the pond.

  • Protect the socket and plugagainst moisture. Use a drip loop to ensure that water cannot reach the socket via the power cord.

  • Don’t use the product if the device, cord or plug is damaged. Return the device to your dealer for repair or recycling. A damaged cord or plug cannot be replaced, the device should be recycled.

  • Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.

  • Always switch off all devices in the pond before maintenance. Disconnect the plug(s) from the socket.

  • The air pump will overheat and get damaged if it cannot discharge air within adequately. Never close the outlets, making sure the air tubes are not closed or kinked, at the same ensuring the air stones are not blocked or to old.

  • ****This device can be used by children aged from 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safeway and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.

  • Modifications to the device may affect the safety. The warranty will also expire.

Function

The Koi-Flow air pump provides water movement in the pond, allowing oxygen and gas exchange to take place at the water surface. During the winter, an air pump can keep an existing ice hole open.

Installation

NOTICE! Place the air pump in a dry place protected from moisture.
Fig.A Always position the air pump above the water level. Siphoning effect can cause water to run into the air pump and cause damage.

  • Water damage is not covered by the warranty!
  • Connect the air hose with the air stone to the outlet of the air pump.
  • Turn the air pump on by putting the plug in the socket.

NOTICE! You can also place an air stone in your filter, it will improve the biological filtration and growth of beneficial bacteria.

Maintenance

  • A decrease in air output, can be caused through kinked hosing or debris within the airstone. Alternatively, the valves in the air chambers or diaphragms may be worn and need to be replaced.
  • Koi-Flow Service Kits (2 membranes, 2 air chambers, 2 connecting hoses and 1 air filter) are available from your dealer.
  • Wear of the valves and diaphragms is normal and is not covered by the warranty.
  • Remove the hood by unscrewing the eight screws on the bottom of the pump Fig.B Remove the connecting hoses (a) and unscrew the air chambers (b).
  • Unscrew the support discs with cover plates (c) and remove the diaphragm cases (e) from the housing.
  • Press the old diaphragms (d) out of the diaphragm cases, press the new diaphragms correctly into the cases (with the tab in the recess).
  • Replace the holders and screw on the support discs with cover plates.
  • Screw on the new air chambers and connect the new connecting hoses (secure with ties).
  • Also check the inside of the air pump for dirt, moisture and rust.
  • Re-assemble the hood.

NOTICE! Replace air tube and air stones yearly. Old and cracked ones will reduce performance and durability of the air pump.

Recycling

This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste. Instead it must be handed in at an official collection centre (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products.
Separate collection and recycling are better for the environment, public health and reduces waste.

Warranty

2 years manufacturer’s warranty on materials and construction defects. Devices must be returned complete with all components, accompanied with an official proof of purchase confirming a purchase date for any warranty claims. Incomplete devices of which parts are missing, and devices without proof of purchase are not eligible for warranty. After receiving and checking, we will determine whether the device will be repaired or replaced. For a device repaired or replaced under warranty, the remaining time of the original warranty period applies. Carefully read the instructions on installation, use and maintenance. Damage due to incorrect use, damage due to immersion in water, damage due to contamination or not cleaning the device and damage to the cord are not covered by the warranty.
Always keep the proof of purchase, without proof of purchase the warranty will be void!

| Koi-Flow 20| 0 Koi-Flow 30| Koi-Flow 60
---|---|---|---
Output| 1200 L/h| 1800 L/h| 3600 L/h
Pressure| 0.025 MPa| 1800 L/h| 0.025 MPa
Power| 15 Watt| 25 Watt| 35 Watt

Produced in China for:
www.aquadistri.com
Vlietweg 8, 4791 EZ Klundert, The Netherlands

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals