STAUBLI MA707 MC4-Evo 2 In-line Fuse PV-K/1500ILF3 User Manual
- June 3, 2024
- STAUBLI
Table of Contents
MA707 MC4-Evo 2 In-line
Fuse PV-K/1500ILF3
User Manual
Verschlusskappen/Sealing caps
PV-SVK4 32.0717
PV-BVK4 32.0716
MA707 MC4-Evo 2 In-line Fuse PV-K/1500ILF3
Safety instructions
Importance of the assembly instructions
NOT following the assembly and safety instructions could result in life-
threatening injuries due to electric shock, electric arcs, fi re, or failure
of the system.
- Follow the entire assembly instructions.
- Use and install the product only according to this assembly instructions and the technical data.
- Safely store the assembly instructions and pass them on to subsequent users.
Requirements for personnel
Only an electrician or electrically instructed person may assemble, install, and commission the system.
- An electrician is a person with appropriate professional training, knowledge, and experience to identify and avoid the dangers that may originate from electricity. An electrician is able to choose and use suitable personal protective equipment.
- An electrically instructed person is a person who is instructed or supervised by an electrician and can identify and avoid the dangers that may originate from electricity.
Intended use
The In-line Fuses interrupt DC circuits in case of over-currents.
Prerequisites for installation and assembly
- NEVER use an obviously damaged connector of In-line Fuse.
- ONLY tools and procedures approved by Stäubli shall be used.
Safe assembly and mounting
Live parts can remain energized after isolation or disconnection
- ONLY Install the product when the photovoltaic-array or -string is de-energized.
Mating and disconnecting
- ALWAYS de-energize the photovoltaic system before mating and disconnecting the connectors.
- NEVER disconnect the connectors under load.
- NEVER connect male or female part of Stäubli connector with connectors of other manufacturers.
- NEVER reconnect a string without an In-line Fuse, if the In-line Fuse was disconnected from this string.
Do NOT modify NOR repair component
- Do NOT modify component.
- Replace defective components.
Technical data
Product designation|
---|---
Voltage rating| DC 1500 V
Test voltage| 8 kV
Safety class| II
Overvoltage category
Pollution degree| CATIII/3
Upper Limiting Temperature
(ULT)| 115° C
Ambient temperature range| -40 °C… +50 °C
Degree of Protection (IP)| IP65/IP68 (1 m, 1 h)
Insulation material| Polyamide/EVA/XLPE
Mating connectors
Only genuine Stäubli connectors shall be used!| PV-KST4/… oder/or PV-KBT4/…
(“MC4”)1),
PV-KBT4-EVO 2… oder/or PV-KST4-EVO 2… (“MC4-Evo 2”)
Rated current gPV| 4 A
5 A
6 A
15 A
20 A
Transportation/storage temperature range| -40 °C bis/to +50 °C
TUV Rheinland certified acc. to 2PfG 2380/10.21| R 60163375
Fuse link gPV certified acc. to IEC60269-6:2010+Amd1| J 50524015
1)Attention:
When connecting the connectors, it must be ensured that the rated data
(current carrying capacity and rated voltage) of the products are dependent on
the mating connectors used.
Observe the information in the assembly instructions for the connectors used.
Tools/assembly materials required
For integration into a PV cable harness system:
(ill. 1)
for MC4-Evo 2 connectors: Assembly and unlocking tool, PV-MS-PLS, order
No. 32.6058
Note:
Operating instructions MA270,
www.staubli.com/electrical
Installation procedure
Important ELECTRIC SHOCK HAZARD:
Do not disconnect the In-line Fuse under load nor connect it in an electrical
circuit that is under load.
|
---|---
(ill. 2 – 3)
Using the appropriate disconnect tool, separate the mated connector pair where
the In-line Fuse will be located.
Notes on installation
General notes on installation
- Unmated connectors must be protected from environmental im-pact (moisture, dirt, dust, etc.) with sealing caps (socket order no. 32.0716; plug order no. 32.0717).
- Do not mate contaminated connectors.
- Connectors must not come into contact with any chemicals.
Cable routing
Cable management must allow a minimum of 20 mm of cable that exits directly
from the cable seal without bending or stress. Refer to cable manufacturers
specification for minimum bending radius.
When installing in bundles (n = >1), the temperature ratings of the product
and the relevant standards and regulations must be taken into account.
Contaminated/damaged connectors:
- Do not allow connectors to be contaminated by the environment (e.g.soil, water, insects, dust).
- Do not allow the connector to be contaminated on its surface (e.g. stickers, paint, heat shrink tubing)
- Do not allow that the connector is directly on the roofing surface.
- Do not allow that the connector is at the lowest point of cabling where water can collect
- Do not allow that the connector is in standing water
- Do not allow that cable ties to be mounted directly on the connector body.
Mechanical stress:
- Check that the connectors are not subjected to a permanent mechanical tensile load or vibration
- Connectors shall not be under strain from cable management
Notes:…….
Global Headquarters:
Stäubli Electrical Connectors AG
Stockbrunnenrain 8
4123 Allschwil/Switzerland
Tel. +41 61 306 55 55
Fax +41 61 306 55 56
mailec.ch@staubli.com
www.staubli.com/electrical
© by Stäubli Electrical Connectors AG, Switzerland – MA707 – 07.2022,
Index a, Marketing Communications – Änderungen vorbehalten/Subject to
alterations