FRIGIDAIRE FG7MQ Fully Modulating Variable Speed Condensing Upflow Horizontal Gas Furnace Owner’s Manual

June 15, 2024
Frigidaire

FRIGIDAIRE-LOGO

FRIGIDAIRE FG7MQ Fully Modulating Variable Speed Condensing Upflow

Horizontal Gas Furnace

Product Information

Technical Specifications
The FG7MQ is a fully modulating, variable speed, condensing upflow/horizontal gas furnace. It has an induced draft and a 97.0 AFUE (Annual Fuel Utilization Efficiency) rating. The input ranges from 60,000 to 120,000 Btuh. The furnace can be installed free-standing in a utility room, basement, or enclosed in an alcove or closet. It is design certified by CSA for application in Canada and the United States.

Warranty
No information provided in the text extract.

Features and Benefits

  • Fully modulating design for precise temperature control
  • Variable speed blower for improved energy efficiency
  • Condensing technology for increased fuel efficiency
  • Induced draft for efficient combustion
  • 97.0 AFUE rating for high energy savings

Dimensions

Dimension A: 15 inches
Dimension B: 16 inches
Dimension C: 21 inches

Model Identification Code

  • The model identification code for the gas furnace is FG7MQ 060 D V B.
  • Cabinet Width: B = 17.50 inches, C = 21.00 inches, D = 24.50 inches
  • Cooling Airflow: V = VSB (no further information provided)
  • Input Heating Capacity: 060 = 60,000 Btuh, 080 = 80,000 Btuh,100 = 100,000 Btuh, 120 = 120,000 Btuh

Location of Furnace Components
No specific information provided in the text extract.

Specifications

Model Numbers| Input-Btuh (a)| Heating Capacity-Btuh| AFUE| Variable Speed Blower| Gas Connection| Weight
---|---|---|---|---|---|---
-060D-VB| 60,000/30,000| 58,200/29,100| 97.0| 11×8 1/2| Variable| 130 lbs
-080D-VC| 80,000/40,000| 77,600/38,800| 97.2| 11×10 3/4| Variable| 140 lbs
-100D-VC| 100,000/50,000| 97,000/48,500| 97.4| 11×10 3/4| Variable| 150 lbs
-120D-VD| 120,000/60,000| 116,400/58,200| 97.0| 11×10 1| Variable| 165 lbs

Airflow Data

Gas Input Rate (Btuh)| Full Input CFM at 50°F Rise| Minimum Input CFM at 50°F Rise| Full Input CFM at 55°F Rise| Minimum Input CFM at 55°F Rise| Full Input CFM at 60°F Rise| Minimum Input CFM at 60°F Rise| Full Input CFM at 65°F Rise| Minimum Input CFM at 65°F Rise
---|---|---|---|---|---|---|---|---
60,000| 1,000| 560| 940| 515| 850| 470| 950| 950
80,000| 1,345| 740| 1,255| 685| 1,140| 625| 1,300| 1,300
100,000| 1,680| 925| 1,565| 855| 1,460| 780| 1,760| 1,760
120,000| 2,020| 1,115| 1,890| 1,025| 1,730| 940| 2,100| 2,100

Maximum Pipe Length Chart

Furnace Models (BTU)| SINGLE VENT PIPE LENGTH (FT.) with 1 long radius elbow| DUAL VENT PIPE LENGTH (ft.) with 1 long radius elbow on each
pipe

---|---|---
60,000| 50 (Outlet 2 Diameter), 80 (Outlet 3 Diameter)| N/A
80,000| 40 (Outlet 2 Diameter), 80 (Outlet 3 Diameter)| N/A
100,000| 60 (Outlet 2 Diameter), 90 (Outlet 3 Diameter)| 90
120,000| 50 (Outlet 2 Diameter), 90 (Outlet 3 Diameter)| 70

Product Usage Instructions

Installation

The FG7MQ gas furnace can be installed free-standing in a utility room, basement, or enclosed in an alcove or closet. It is suitable for both upflow and horizontal applications. The extended flush jacket provides a pleasing appliance appearance. Please refer to the installation manual for detailed instructions on how to install the furnace in your desired location.

Operation

To operate the FG7MQ gas furnace, follow these steps:

  1. Ensure that the gas supply is turned on and the thermostat is set to the desired temperature.
  2. The furnace will automatically modulate the gas flow and adjust the blower speed to maintain the set temperature.
  3. If there are any issues with the furnace’s operation, refer to the troubleshooting section of the user manual.

Maintenance

To ensure optimal performance and longevity of the FG7MQ gas furnace, regular maintenance is recommended. Here are some maintenance tasks:

  • Clean or replace the air filters regularly to ensure proper airflow.
  • Inspect and clean the combustion chamber and burners annually.
  • Lubricate the blower motor bearings as per the manufacturer’s instructions.
  • Check and clean the condensate drain to prevent blockages.
  • Inspect the venting system for any obstructions or damage.

Safety Precautions
When operating and maintaining the FG7MQ gas furnace, it is important to follow these safety precautions:

  • Always turn off the gas supply and power before performing any maintenance or repair tasks.
  • Ensure proper ventilation in the installation area to prevent the buildup of carbon monoxide.
  • Keep flammable materials away from the furnace.
  • Do not attempt to modify or repair any components without proper knowledge and training.
  • If you smell gas or suspect a gas leak, immediately evacuate the area and contact a qualified technician.

Frequently Asked Questions (FAQ)

Q: What is the AFUE rating of the FG7MQ gas furnace?
A: The AFUE rating of the FG7MQ gas furnace is

TECHNICAL SPECIFICATIONS

Fully Modulating,Variable Speed, Condensing
Upflow/Horizontal Gas Furnaces
Induced Draft – 97.0 AFUE
Input 60,000 – 120,000 Btuh
The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. Upflow/horizontal units come ready for upflow or horizontal application. The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.

WARRANTY

  • 10 Year all-parts warranty.
  • 10 Year Quality Pledge to replace the unit if the heat exchanger fails within the first 10 years of operation, to the original owner.
  • Consumer product registration required for 10 year All Parts Warranty and Quality Pledge within a limited period of time after the installation. See current warranty document or visit our consumer web site listed on the back of this document for warranty details.
  • When registered, this product is upgraded to a limited lifetime heat exchanger warranty.

FEATURES and BENEFITS

  • i SEER: Energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling.
  • Modulating heating operation Includes:
    • Modulating gas valve from 100% to 50% input in 5% increments.
    • Time proportioning modulation down to 15%.
    • Variable speed inducer and blower.
  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • 30 second blower delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 second post purge: Increases life of heat exchanger.
  • Hot surface igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite® technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
  • High Static Blowers: All models equipped with high static blowers.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life.
  • 90 second fixed cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
  • LP convertible: Simple burner orifice change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting flashess: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Incorporates integrated control board : with connections for electronic air cleaner and humidifier.
  • Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
  • Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation.
  • Sealed Vestibule: Reduces burner and inducer sound levels.
  • iQ Drive Thermostat: Provides modulation down to 15% and is required for furnace operation.

DIMENSIONS

*MQ Model #’s| Dimension “A”| Dimension “B”| Dimension “C”
---|---|---|---
060D-VB| 17 1/2| 15 7/8| 16 1/8
080D-VC| 21| 19 3/8| 19 5/8
100D-VC
120D-VD| 24 1/2| 22 7/8| 23 1/8

FRIGIDAIRE-FG7MQ-Fully-Modulating-Variable-Speed-Condensing-Upflow-
Horizontal-Gas-Furnace- 1

FG7MQ 97+ Modulating Upflow/Horizontal Series

MODEL IDENTIFICATION CODE

FRIGIDAIRE-FG7MQ-Fully-Modulating-Variable-Speed-Condensing-Upflow-
Horizontal-Gas-Furnace-2

LOCATION OF FURNACE COMPONENTS

FRIGIDAIRE-FG7MQ-Fully-Modulating-Variable-Speed-Condensing-Upflow-
Horizontal-Gas-Furnace-3

SPECIFICATIONS

FG7MQ MODEL NUMBERS:| ****

-060D-VB

| ****

-080D-VC

| ****

-100D-VC

| ****

-120D-VD

---|---|---|---|---
Input – Btuh (a)| 60,000 / 30,000| 80,000 / 40,000| 100,000 / 50,000| 120,000 / 60,000
Heating Capacity – Btuh| 58,200 / 29,100| 77,600 / 38,800| 97,000 / 48,500| 116,400 / 58,200
AFUE| 97.0| 97.2| 97.4| 97.0
Blower D x W| 11 x 8| 11 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/2 – Variable| 3/4 – Variable| 3/4 – Variable| 1 – Variable
Motor FLA| 6.2| 8.7| 8.7| 11.70
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65| 40-70
Shipping Weights| 130lbs| 140lbs| 150lbs| 165lbs

NOTE: All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

iQ Controller Kit

Description Sku
iQ Controller kit 920621*

Revision Letter

AIRFLOW DATA


Gas Input Rate (Btuh)

| Target CFM for Selected Circulating Air Temperature Rises, F
---|---
45| 50| 55| 60| ****

Constant

Full Input| Minimum Input| Full Input| Minimum Input| Full Input| Minimum Input| Full Input| Minimum Input
60,000| 1,110| 635| 1,000| 560| 940| 515| 850| 470| 950
80,000| 1,480| 850| 1,345| 740| 1,255| 685| 1,140| 625| 1,300
100,000| 1,850| 1,050| 1,680| 925| 1,565| 855| 1,460| 780| 1,760
120,000| 2,225| 1,270| 2,020| 1,115| 1,890| 1,025| 1,730| 940| 2,100

NOTE: This table lists the High and Low target CFMs for each maximum input rate and temperature rise. If the target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used.

MAXIMUM PIPE LENGTH CHART


FURNACE MODELS (BTU)

| ****

FURNACE INSTALLATION

| SINGLE VENT PIPE LENGTH (FT.)

**with 1 long radius elbow***

| DUAL VENT PIPE LENGTH (ft.)

**with 1 long radius elbow on each pipe***

---|---|---|---
OUTLET

2” Diameter

| OUTLET

3” Diameter

| INLET/OUTLET

2” Diameter

| INLET/OUTLET

3” Diameter

60,000| Upflow| 50| 80| 50| 80
Horizontal| 40| 80| 40| 80
80,000| Upflow| 60| 90| 60| 90
Horizontal| 50| 90| 50| 90
100,000| Upflow| 50| 90| 50| 90
Horizontal| 40| 90| 40| 90
120,000| Upflow| N/A| 90| N/A| 90
Horizontal| N/A| 70| N/A| 70

NOTES:

  1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Two 45° elbows are equivalent to one 90° elbow.
  2. Subtract 5ft for each 2” tee and 8ft for each 3” tee.
  3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.
  4. The minimum length for 2” or 3” diameter vent pipe is 5 ft.

ACCESSORIES

FG7MQ KITS

Description| SKU
2″ Concentric vent kit| 904177
3″ Concentric vent kit| 904176
2″ Side wall vent kit| 904617
3″ Side wall vent kit| 904347
U.S. LP Conversion kit (0 to 10,000 ft.) for US and Canada| 904950
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036
Neutralizer kit| 902377
Outdoor sensor for conventional heat pump| 920938

GENERAL TERMS OF LIMITED WARRANTY

NORDYNE will furnish a replacement for any part of this product which fails in normal use and service within the first ten years of installation, in accordance with the terms of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy.

8000 Phoenix Parkway | O’Fallon, MO 63368-3827
Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (03/2011)

www.frigidairehvac.com

FRIGIDAIRE is a registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Frigidaire User Manuals

Related Manuals