true SPEC Series Heated Cabinets Installation Guide
- June 4, 2024
- TRUE
Table of Contents
- **
- true SPEC Series Heated Cabinets
- REPLACEMENT PARTS
- INSTALLATION
- HOW TO CONNECT ELECTRICITY
- ELECTRIC INSTALLATION & SAFETY INFORMATION
- INSTALLATION OF CASTORS OR OPTIONAL LEGS
- SEALING CABINET TO FLOOR
- ROLL-IN & ROLL-THRU RAMP INSTALLATION
- HUMIDIFICATION PROCEDURE
- SETUP
- PILASTER INSTALLATION & OPERATION
- SHELF INSTALLATION:
- CONFIGURATION (PILASTERS):
- DOOR OPERATION
- OPERATION
- ELECTRONIC TEMPERATURE CONTROLS
- USING THE LAE ELECTRONIC CONTROL
- MAINTENANCE, CARE, CLEANING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**
**
true SPEC Series Heated Cabinets
NOTICE TO
CUSTOMER
Loss or spoilage of products in your refrigerator/freezer is not covered by
warranty. In addition to following recommended installation procedures you
must run the refrigerator/freezer 24 hours prior to usage.
SAFETY INFORMATION
How to Maintain Your True Refrigerator to Receive the Most Efficient and
Successful Operation.
You have selected one of the finest commercial refrigeration units made. It is
manufactured under strict quality controls with only the best quality
materials available. Your TRUE cooler when properly maintained will give you
many years of trouble-free service.
WARNING: Use this appliance for its intended purpose as described in this
Owner Manual.
SAFETY PRECAUTIONS
When using electrical appliances, basic safety precautions should be followed,
including the following:
- This unit must be properly installed and located in accordance with the Installation Instructions before it is used.
- Do not allow children to climb, stand or hang on the shelves in the refrigerator. They could damage the unit and seriously injure themselves.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Keep fingers out of the “pinch point” areas; clearances between the doors and between the doors and cabinet are necessarily small; be careful closing doors when children are in the area.
- Unplug the unit before cleaning and making repairs.
NOTE:
We strongly recommend that any servicing be preformed by a qualified
technician.
DANGER!
RISK OF CHILD
ENTRAPMENT
PROPER DISPOSAL OF THE UNIT
Child entrapment and suffocation are not problems of the past. Junked or
abandoned refrigerators are still dangerous… even if they will sit for “just a
few days.” If you are getting rid of your old refrigerator, please follow the
instructions below to help prevent accidents.
BEFORE YOU THROW AWAY YOUR OLD UNIT:
- Take off the doors.
- Leave the shelves in place so that children may not easily climb inside.
USE OF EXTENSION CORDS
NEVER USE AN EXTENSION CORD! TRUE will not war-ranty any refrigerator
that has been connected to an extension cord.
REPLACEMENT PARTS
- Component parts shall be replaced with like components.
- Servicing shall be done by authorized service personnel, to minimize the risk of possible ignition due to incorrect parts or improper service.
- Lamps must be replaced by identical lamps only.
- If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
WARNING!
HOW TO CONNECT ELECTRICITY
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE GROUND PRONG FROM THE POWER
CORD. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord from this appliance is equipped with a grounding plug which
minimizes the possibility of electric shock hazard. Have the wall outlet and
circuit checked by a qualified electrician to make sure the outlet is properly
grounded. If the outlet is a standard 2-prong outlet, it is your personal
responsibility and obligation to have it replaced with the properly grounded
wall outlet. The refrigerator should always be plugged into it’s own
individual electrical circuit, which has a voltage rating that matches the
rating plate. This provides the best performance and also prevents overloading
building wiring circuits which could cause a fire hazard from over-heated
wires. Never unplug your refrigerator by pulling on the power cord. Always
grip plug firmly and pull straight out from the outlet. Repair or replace
immediately all power cords that have become frayed or otherwise damaged. Do
not use a cord that shows cracks or abrasion damage along its length or at
either end. When removing the refrigerator away from the wall, be careful not
to roll over or damage the power cord. If supply power cord is damaged it
should be replaced with original equipment manufacture parts. To avoid hazard
this should be done by a qualified service technician.
USE OF ADAPTER PLUGS
NEVER USE AN ADAPTER PLUG! Because of potential safety hazards under
certain conditions, we strongly recommend against the use of an adapter plug.
The incoming power source to the cabinet including any adapters used must have
the adequate power available and must be properly grounded. Only adapters
listed with UL should be used.
NORTH AMERICA USE ONLY!
NEMA plugs
TRUE uses these types of plugs. If you do not have the right outlet have a
certified electrician install the correct power source.
NOTE:
International plug configurations vary by voltage and country.
INSTALLATION
OWNERSHIP
To ensure that your unit works properly from the first day, it must be
installed properly. We highly recommend a trained refrigeration mechanic and
electrician install your TRUE equipment. The cost of a professional
installation is money well spent.
Before you start to install your TRUE unit, carefully inspect it for freight
damage. If damage is discovered, immediately file a claim with the delivery
freight carrier.
TRUE is not responsible for damage incurred during shipment.
UNCRATING
TOOLS REQUIRED
- Adjustable Wrench
- 1/2 inch socket (Castor Bolts)
- 3/4 inch socket (Skid Bolts)
- Level
The following procedure is recommended for uncrating the unit:
- A. Remove the outer packaging, (cardboard and bubbles or Styrofoam corners and clear plastic). Inspect for concealed damage. Again, immediately file a claim with the freight carrier if there is damage.
- B. Move your unit as close to the final location as possible before removing the wooden skid.
NOTE:
KEYS FOR COOLERS WITH DOOR LOCKS ARE LOCATED IN WARRANTY PACKETS.
LOCK AND KEYS
The following procedure is for locking and unlock unit:
- A. Insert the key and turn.
- B. Remove the key.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the ground prong from the power cord. For personal safety, this appliance must be properly grounded. The power cord of this appliance is equipped with a grounding plug which mates with a standard grounding wall outlet to minimize the possibility of electric shock hazard from this appliance. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. If the outlet is a standard 2-prong outlet, it is your personal responsibility and obligation to have it replaced with the properly grounded wall outlet. The unit should always be plugged into its own individual electrical circuit, which has a voltage rating that matches the rating plate. This provides the best perfor-mance and also prevents overloading building wiring circuits which could cause a fire hazard from overheated wires. Never unplug your unit by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet. Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end. When removing the unit away from the wall, be careful not to roll over or damage the power cord.
ELECTRIC INSTALLATION & SAFETY INFORMATION
- If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
- Lamps must be replaced by identical lamps only.
- Appliance tested according to the climate classes 5 and 7 temperature and relative humidity.
ELECTRICAL INSTRUCTIONS
- A. Before your new unit is connected to a power supply, check the incoming voltage with a voltmeter. If anything less than 100% of the rated voltage for operation is noted, correct immediately.
- B. All units are equipped with a service cord, and must be powered at proper operating voltage at all times. Refer to cabinet data plate for this voltage.
TRUE RECOMMENDS THAT A SOLE USE CIRCUIT BE DEDICATED FOR THE UNIT.
WARNING:
Power supply cord ground should not be removed!
NOTE:
To reference wiring diagram, remove front louvered grill, wiring diagram is
positioned on the inside cabinet wall.
WIRE GAUGE CHART
115 Volts | Distance In Feet To Center of Load | |
---|---|---|
Amps | 20 | 30 40 50 60 70 80 90 100 120 140 160 |
2 | 14 | 14 14 14 14 14 14 14 14 14 14 14 |
3 | 14 | 14 14 14 14 14 14 14 14 14 14 12 |
4 | 14 | 14 |
--- | --- | --- |
5 | 14 | 14 |
6 | 14 | 14 |
7 | 14 | 14 |
8 | 14 | 14 |
9 | 14 | 14 |
10 | 14 | 14 |
12 | 14 | 14 |
14 | 14 | 14 |
16 | 14 | 12 |
18 | 14 | 12 |
20 | 14 | 12 |
25 | 12 | 10 |
30 | 12 | 10 |
35 | 10 | 10 |
40 | 10 | 8 |
45 | 10 | 8 |
50 | 10 | 8 |
LOCATING
- Make sure unit is as close to the final location as possible.
- Remove the shipping bolts located at the bottom of the wooden skid.
- Carefully slide the unit off the wooden skid. Slide packing material underneath the side of the unit hanging off the skid. Then install castors or legs for that side of the unit.
- Then carefully slide the other side of the unit off one corner at a time while installing castors or legs for each corner. Use packing material for under each corner of the unit before installing a castor or leg.
INSTALLATION OF CASTORS OR OPTIONAL LEGS
Important Safeguard for installation of leg/castor. Images 1-5 demonstrate procedure.
-
Slide packing material under the unit.
-
Anchor castor.
-
Thread leg into cabinet bottom cabinet.
-
The end of the leg is adjustable for easy leveling.
-
Castor with leveling shims.
SECURING CASTORS AND LEGS
To obtain maximum strength and stability of the unit, it is important that you
make sure each castor is secure. Optional legs are hand-tightened securely
against the lower rail assembly. The bearing race on the castor or the top
edge of the leg must make firm contact with the rail.
LEVELING SHIMS
Four leveling shims have been provided for leveling castored units positioned
on uneven floors. Shims must be positioned between rail end and bearing race.
- A. Turn the bearing race counter-clockwise until the cabinet is level. Level front to back and side to side. (diagonally)
- B. Install the desired number of shims, making sure the slot of the shim is in contact with the threaded stem of the castor.
- C. If more than one shim is used, turn the slot at a 90° angle so they are not in line.
- D. Turn the bearing race clockwise to tighten and secure the castor by tightening the anchoring bolt with a 3/4 inch open-end wrench or the tool provided.
CAUTION:
TO AVOID DAMAGE TO LOWER RAIL ASSEMBLY, SLOWLY RAISE UNIT TO UPRIGHT POSITION.
NOTE:
OPEN HOLES LOCATED ON THE CROSS MEMBERS OF THE FRAME RAIL SHOULD BE PLUGGED
BEFORE UNIT IS IN USE.
LEVELING
- A. Proper leveling of your TRUE unit is critical to operating success (for non-mobile models). Effective door operation will be effected by leveling.
- B. The unit should be leveled front to back and side to side with a level.
- C. Free plug and cord from the top of the unit (do not plug in).
- D. The unit should be placed close enough to the electrical supply so that extension cords are never used.
NOTE:
If the cabinet has a center leveling screw, castor, or leg, make sure it is
adjusted properly so it makes full contact with the floor after the cabinet
has been leveled.
WARNING:
WARRANTIES ARE VOID IF THE
UNIT IS MORE THAN 7 FT. (2.1M) FROM PLUG-IN CONNECTION.
SEALING CABINET TO FLOOR
STEP 1 – Position Cabinet – Allow one inch between the wall and rear of
the refrigerator to assure proper ventilation. For freezers 3 inches between
the wall and rear of the cabinet will assure proper ventilation.
STEP 2 – Level Cabinet – Cabinet should be level, side to side and front
to back. Place a carpenter’s level in the interior floor in four places:
- A. Position level in the inside floor of the unit near the doors.(Level should be parallel to cabinet front). Level cabinet.
- B. Position level at the inside rear of cabinet. (Again level should be placed parallel to cabinet back).
- C. Perform similar procedures to steps A & B by placing the level on inside floor (left and right sides – parallel to the depth of the cooler). Level cabinet.
STEP 3 – Draw an outline on the base on the floor.
STEP 4 – Raise and block the front side of the cabinet.
STEP 5 – Apply a bead of NSF Approved Sealant, (see list below), to floor
on half inch inside the outline drawn. The bead must be heavy enough to seal
the entire cabinet surface when it is down on the sealant.
STEP 6 – Raise and block the rear of the cabinet
STEP 7 – Apply sealant on floor as outlined in Step 5 on other three
sides.
STEP 8 – Examine to see that cabinet is sealed to floor around entire
perimeter.
NOTE:
Asphalt floors are very susceptible to chemical attack. A layer of tape on
the floor prior to applying the sealant will protect the floor.
NSF APPROVED SEALANTS:
- Minnesota Mining #ECU800 Caulk
- Minnesota Mining #ECU2185 Caulk
- Minnesota Mining #ECU1055 Bead
- Minnesota Mining #ECU1202 Bead
- Armstrong Cork – Rubber Caulk
- Products Research Co. #5000 Rubber Caulk
- G.E. Silicone Sealer
- Dow Corning Silicone Sealer
ROLL-IN & ROLL-THRU RAMP INSTALLATION
Once the cabinet is in its final location and level the roll-in ramp can be
installed. The ramp has three slotted holes in back. These slotted holes slide
over three thumb screws located in the front of the cabinet near the floor.
DOOR SWEEP
GASKET ADJUSTMENT
To adjust door sweeper gasket, loosen slotted thumbscrews. The gasket can then
be moved up or down and side to side. The gasket should make some contact with
the ramp when the door is closing. This can be checked by opening up the door
3-4″ and allowing the door to close. This process may have to be done several
times before securing the sweeper gasket bracket. Once gasket is properly
adjusted, tighten slotted thumbscrews. See image 5.
HUMIDIFICATION PROCEDURE
ADJUSTING HUMIDITY
This instruction is TRUE’s recommended procedure for providing interior
humidity control. The heated cabinet is designed to provide flexibility in
desired interior humidity.
LOW HUMIDITY
- A. Positioned on top of the unit and behind the rain shield is the manual humidity control. To access the humidity control see instruction above to secure rainsheild in the open position.
- B. Turn counterclockwise to ventilate cabinet humidity. (See photo below)
HIGH HUMIDITY
- A. When cabinet contents require higher humidity, close the vent shown below.
SETUP
STANDARD ACCESSORIES
PILASTER INSTALLATION & OPERATION
TRUE STR, STA, and STG cabinets are available with four different shelving / tray slide options.
- Type Kit #1. Angle Type Tray Slide
- Type Kit #2. Rod Style Tray Slide
- Type Kit #3. Universal Tray Slide
- Type Kit #4. Shelf Standards (shelf clips)
REQUIRED TOOLS:
- Standard Screwdriver (Flathead)
- Rubber / Plastic Mallet
- Tape Measure
INSTALLATION PROCEDURES (WIRE SHELVES):
Wire shelves come with shelf clips .Properly insert the shelf clips in the desired height
(remember all shelf clips will need to be installed at the same height to keep
the shelf level.) Once the shelves are installed the remaining threaded holes
will have thumb screws inserted. These thumb screws are provided in the unit.
- Type Kit #4 (Shelf Standards / Shelf Clips)
WARNING!
Do not use pliers or any crimping tools when installing shelf clips. Altering
shelf clips in any way can lead to shelving instability.
SHELF INSTALLATION:
For Proper Shelf Clip Installation Please Read The Following Instructions.
STEP 1
Install the top tab of the shelf clip into the proper hole. Push up on the bottom of the clip. .
STEP 2
Bottom tab of the shelf clip will fit tightly. You may need to squeeze or
twist the bottom of the shelf clip to install. .
STEP 3
After installation, the shelf clip will fit snug into the shelf standard. The
shelf clip should not be loose or able to wiggle out of the shelf standard.
SHELF
INSTALLATION TIPS
- Install all the shelf clips before installing the shelves.
- Start at the bottom in terms of shelf installation and work your way up.
- Always lay the back of each shelf down on the rear clips before the front.
CONFIGURATION (PILASTERS):
-
Type Kit #1 (Angle Type Tray Slide)
-
Type Kit #2 (Rod Style Tray Slide)
-
Type Kit #3 (Universal Tray Slide)
-
Pilaster installation (side wall of cabinet)
-
Pilaster installation two and three door models (middle of wall in rear of cabinet)
-
Pilaster installation (back wall of cabinet for two & three door models)
Each TRUE Specification Series (STR, STA, and STG) is available with two pilaster configurations. Each configuration depends on the end user preference. Multiple door units can have two configurations for each section. .
INSTALLATION PROCEDURES (PILASTERS):
Install slotted thumb screws into threaded holes along the inside wall of the
cabinet. Slide pilasters into position behind the slotted screws. Leave all of
the thumb screws loose for adjustments when installing tray slides. It is
critical to measure from the center of the square hole on the front pilaster
to the center hole of the rear pilaster. This measurement should be 24 5/8″
(625 mm).
- Critical measurement front to rear pilasters
Do the same on the opposite side of cabinet for single door. Make sure the measurement of 24 5/8″ (625 mm) is the same in the center pilasters in 2 and 3 door units. Tap the tray slides into the Pilasters with a rubber Mallet. Angle & Rod Type shelving uses a 18 1/8″ (460 mm) distance between Pilasters. Universal Tray slides have a 21 1/4″ (540 mm) distance between Pilasters.
- Top view: Critical Measurement side to side
After the pilasters are installed the Universal Tray, Angle Type Tray, and Rod Style Tray Slides will slide into the pilasters. See images 1-6. When disassembling or changing tray slides a rubber mallet may be used to take out the different tray slides. Gently tap on the under side of the tray slide to loosen it from the pilaster.
DOOR OPERATION
DOOR CONFIGURATION:
After installing, cabinet doors can be adjusted for alignment. The hinge on
the door and hinge on the cabinet can be adjusted accordingly.
STEP 1
To remove door open at a 90˚ angle from the cabinet and lift door up and out
from the cabinet hinges carefully avoiding rain shield. Rest the door in a
safe area.
STEP 2
Remove gray plastic cover from hinge located on the cabinet. Use a standard screw driver and pry
out the gray cover. This exposes the three Phillips screws anchoring the hinge
to the cabinet. Loosen
these three screws but don’t remove them. Adjustment can be made slightly
up/down and side to side.
STEP 3
The hinge on the cabinet door can also be adjusted. Remove cover from hinge
located on the door. Pull on the cover directly out from the door. This exposes the three Phillips
screws anchoring the hinge to the door. Loosen these three screws but don’t
remove them. The hinge can be moved side to side, up and down.
NOTE:
WHEN TIGHTENING THE HINGES TO THE CABINET AND DOOR DO NOT APPLY PRESSURE TO
THE PHILLIPS SCREWS. CAREFULLY ANCHOR THEM WITHOUT APPLYING EXTREME AMOUNTS OF
PRESSURE.
STEP 4
To adjust the lock latch remove two Phillips screws and the latch can be put
to the side for later reinstallation. The lock base that anchors the latch can be adjusted simply
by loosening the two Phillips screws, but not removing them. Then the lock
base can be moved side to side for adjustment. After adjustment is complete tighten the lock base and
install the latch back into place.
OPERATION
STARTUP
-
A. The cabinet is ready to operate. Plug in the unit.
-
B. Temperature controls are factory-set to maintain an approxiate temperature of 140°F -180°F (60°C-82°C). Allow unit to function several hours, completely heating cabinet before changing the control setting. Temperature Control Location and Settings.
-
LAE temperature control is located on the front of cabinet in louvered grill.
-
Mechanical temperature control is located on the front of cabinet in louvered grill.
See website for adjustments, sequence of operation, and more information. -
C. Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to replace temperature control, be sure it is ordered from your TRUE dealer or recommended service agent.
-
D. Good air flow in your TRUE unit is critical. Be careful to load product so that it neither presses against the back wall, nor comes within four inches of the evaporator housing. Refrigerated air off the coil must circulate down the back wall.
NOTE:
If the unit is disconnected or shut off, wait five minutes before starting
again.
RECOMMENDATION
Before loading product we recommend you run your TRUE unit empty for two
to three days. This allows you to be sure electrical wiring and installation
are correct and no shipping damage has occurred. Remember, our factory
warranty does not cover product loss!
MECHANICAL TEMPERATURE CONTROLS
AIR SENSING
MECHANICAL
TEMPERATURE CONTROL GENERAL SEQUENCE OF OPERATION
MECHANICAL CONTROL HEATED CABINET GENERAL SEQUENCE OF OPERATION
- Cabinet is plugged in.
- a. Interior lights will illuminate if the rocker switch on the outside panel is in the “ON” position.
- The temperature control will energize the heat elements if the control is calling for heat.
- The temperature control will cycle the heating elements on and off.
- a. The temperature control is sensing the air temperature.
- b. The temperature control should be set between 140°F-180°F (60ºC-82ºC).
- c. The temperature control has an “OFF” position.
- d. The thermometer is designed to read and display a cabinet temperature not a product temperature. This cabinet temperature may reflect the heating cycle determined by the temperature control. The most accurate temperature on a cabinets operation is to verify the product temperature.
ELECTRONIC TEMPERATURE CONTROLS
LAE ELECTRONIC TEMPERATURE CONTROL GENERAL SEQUENCE OF OPERATION
- t1 = supply air / return air* (thermostat)
- t2 = coil / copper line (defrost)
- t3 = return air / supply air* (display)
- STA, STG, STM, STR Models.
- t3 probe is not installed and / or activated in all applications with t3 is not installed and / or activated, the display probe is t1.
LAE MODEL HEATED CABINET ELECTRONIC CONTROL GENERAL SEQUENCE OF OPERATION
- Cabinet is plugged in.
- a. Display will illuminate.
- The LAE control will energize the heat elements if the control is calling for heat.
- The LAE control will cycle the heating elements on and off determined by the Set-Point and Differential temperatures.
- a. The Set-Point is the adjustable preprogrammed temperature which de-energizes the heat elements. This is not the programmed cabinet temperature.
- b. The Differential is the non adjustable preprogrammed temperature that is added to the Set-Point temperature that will re-energize the heat elements.
- c. The LAE control is designed to read and display a cabinet temperature not a product temperature. This cabinet temperature may reflect the heating cycle of the Set-Point and it’s Differential. The most accurate temperature on a cabinets operation is to verify the product temperature.
Example: If the Set-Point is 180°F/82.2°C and the Differential is
1°F/.56°C
(Set-Point) 180°F + 1 (Differential) = 181°F
Or
(Set-Point) 82.2°C + .56 (Differential) = 82.76°C
The heating elements will cycle on 180°F/82.2°C and back off at 181°F/82.76°C
HOW TO DIAGNOSE AN LAE ELECTRONIC CONTROL
Indicator lights for Refrigeration/Heating Mode, Fan Operation, Defrost Mode.
LAE Control| | LAE Control Icons|
---|---|---|---
| |
| | Compressor Running
| |
| | Evaporator Fan Running
| | | | Cabinet in Defrost
| | | | Activation of 2nd
Parameter Set
| | | | Alarm
Info / Set
Point Button| Manual Defrost
/ Down Button| Manual
Activation Up Button| Stand-By Button|
USING THE LAE ELECTRONIC CONTROL
LOCKING AND UNLOCKING THE LAE CONTROLLER:
WHY: Locking of control is necessary to prevent changes to program that may
affect cabinet operation.ّ
HOW TO LOCK AND UNLOCK LAE CONTROLLER:
STEP 1 – To change lock setting press and release the Info button “t1”
will appear.
STEP 2 –
Press the Down button until “Loc” appears. STEP 3 – While pressing and holding the Info button press
the Up or Down button to change the lock settings. If “no” appears, the
controller is unlocked. If “yes” appears, the controller is locked.
STEP 4 –
Once the lock setting has been set correctly release the info button . Wait 5
seconds for the display to show temperature
LAE
Control
-
Info / Set Point Button
-
Manual Defrost / Down Button
-
Manual Activation Up Button
- Stand-By Button
HOW TO TURN OFF THE LAE ELECTRONIC CONTROL:
May need to
unlock control.
WHY: Turning off the control will deactivate all electrical components.
CAUTION:
Turning off the control will not shut off power to the cabinet. Cabinet must
be unplugged prior to any repair.
HOW TO TURN OFF THE LAE ELECTRONIC CONTROL:
STEP 1 – To turn off control, press and hold the Stand-by until button
“OFF” appears. Release Stand-by button.
STEP 2 –
To turn on control, repeat prior steps and a temperature will appear.
TURNING THE GLASS DOOR MODEL LIGHTS ON AND OFF: May need to unlock control.
WHY: Light may be controlled by LAE Controller or interior light switch.
HOW TO TURN THE GLASS DOOR MODEL LIGHT ON
AND OFF:
STEP 1 – To control interior / sign lights by the LAE Controller, press
and release the Manual Activation button .
STEP 2 – To control interior / sign lights by the interior door switch,
depress the rocker switch to the “ON” position. Light switch is located on
inside top right of the ceiling.
- Solid Door model lights are controlled by a door switch.
LAE Control
-
Info / Set Point Button
-
Manual Defrost / Down Button
-
Manual Activation Up Button
-
Stand-By Button
CHANGING THE “SET POINT”:
May need to unlock control.
WHY: The set point is the temperature at which the compressor will shut
off. NOTE: The “set point” IS NOT the cabinet holding temperature.
HOW TO CHANGE THE “SET POINT”:
STEP 1 – To see the set point, press and hold the Info button. STEP 2 – While still holding the
Info button , press the Up or Down button to change the “set point”.
STEP 3 – Once the “set point” has been set correctly release the Info
button . The display will show temperature. LAE Controller Parameter Settings for Celsius
For every model / version of the LAE controller, ALL parameters with a formula
shown need to be converted for Celsius applications.
EXCEPT MODEL: BR1
EXAMPLE:
If current SPL is set for 20 degrees F, the formula is (X-32) / 1.8 (20-32) /
1.8 = -6.7 Celcius
AR2-28
SCL| 1C| | ADO|
SPL| (X-32) / 1.8| AHM|
SPH| (X-32) / 1.8| AHT| (X-32) / 1.8
SP| (X-32) / 1.8| ACC|
C-H| | IISM|
HYS| (X) / 1.8| IISL| (X-32) / 1.8
CRT| | IISH| (X-32) / 1.8
CT1| | IISP| (X-32) / 1.8
CT2| | IIHY| (X) / 1.8
CSD| | IIFC|
DFM| | HDS|
DFT| | IIDF|
DH1| | SB|
DH2| | DS|
DH3| | DSM|
DH4| | DI2|
DH5| | STT|
DH6| | EDT|
DLI| (X-32) / 1.8| LSM|
DTO| | OA1|
DTY| | OA2|
DPD| | CD|
DRN| | INP|
DDM| | OS1| (X) / 1.8
DDY| | T2|
FID| | OS2| (X) / 1.8
FDD| (X-32) / 1.8| T3|
FTO| | OS3| (X) / 1.8
FCM| | TLD|
FDT| (X) / 1.8| TDS|
FDH| (X) / 1.8| AVG|
FT1| | SIM|
FT2| | ADR|
FT3| |
ATM|
ALA| (X-32) / 1.8
AHA| (X-32) / 1.8
ALR| (X) / 1.8
AHR| (X) / 1.8
ATI|
ATD|
BIT25
SPL| (X-32) / 1.8| | ADO|
SPH| (X-32) / 1.8| AHM|
SP| (X-32) / 1.8| AHT| (X-32) / 1.8
HYS| (X) / 1.8| ACC|
| | |
CT1| | IISL| (X-32) / 1.8
CT2| | IISH| (X-32) / 1.8
CSD| | IISP| (X-32) / 1.8
DFM| | IIHY| (X) / 1.8
DFT| | IIFC|
DFB| | IIDF|
DLI| (X-32) / 1.8| SB|
DTO| | DI1|
DTY| | DI2|
DPD| | T3M|
DRN| | OS3| (X) / 1.8
DDM| | PSL| (X-32) / 1.8
DDY| | PSR| (X-32) / 1.8
FID| | POF|
FDD| (X-32) / 1.8| LSM|
FTO| | OA1|
FCM| | OA2|
FDT| (X) / 1.8| OS1| (X) / 1.8
FDH| (X) / 1.8| T2|
FT1| | OS2| (X) / 1.8
FT2| | TLD|
FT3| | SCL| 1C
ATM| | SIM|
ALA| (X-32) / 1.8| ADR|
AHA| (X-32) / 1.8|
ALR| (X) / 1.8
AHR| (X) / 1.8
ATI|
ATD|
BIT25 Heating
SPL| (X-32) / 1.8| | ADO|
SPH| (X-32) / 1.8| SB|
SP| (X-32) / 1.8| DI1|
CM| | DI2|
HYS| (X) / 1.8| PSL| (X-32) / 1.8
TON| | PSR| (X-32) / 1.8
TOF| | POF|
PB| | DSM|
IT| | LSM|
DT| | OA1|
AR| | OA2|
CT| | OS1| (X) / 1.8
PF| | TLD|
HSD| | SCL| 1C
ATM| | SIM|
ALA| (X-32) / 1.8| ADR|
AHA| (X-32) / 1.8|
ALR| (X) / 1.8
AHR| (X) / 1.8
ATD|
MAINTENANCE, CARE, CLEANING
STAINLESS STEEL EQUIPMENT CARE AND CLEANING
CAUTION:
Do not use any steel wool, abrasive or chlorine based products to clean
stainless steel surfaces.
STAINLESS STEEL OPPONENTS
There are three basic things which can break down your stainless steel’s
passivity layer and allow corrosion to rear its ugly head.
- Scratches from wire brushes, scrapers, and steel pads are just a few examples of items that can be abrasive to stainless steel’s surface.
- Deposits left on your stainless steel can leave spots. You may have hard or soft water depending on what part of the country you live in. Hard water can leave spots. Hard water that is heated can leave deposits if left to sit too long. These deposits can cause the passive layer to break down and rust your stainless steel. All deposits left from food prep or service should be removed as soon as possible.
- Chlorides are present in table salt, food, and water. Household and industrial cleaners are the worst type of chlorides to use.
RECOMMENDED CLEANERS FOR CERTAIN SITUATIONS / ENVIRONMENTS OF STAINLESS STEEL
- A. Soap, ammonia and detergent medallion applied with a cloth or sponge can be used for routine cleaning.
- B. Arcal 20, Lac-O-Nu Eco shine applied provides barrier film for fingerprints and smears.
- C. Cameo, Talc, Zud First Impression is applied by rubbing in the direction of the polished lines for stubborn stains and discoloring.
- D. Easy-off and De-Grease It oven aid are excellent for removals on all finishes for grease-fatty acids, blood and burnt-on foods.
- E. Any good commercial detergent can be applied with a sponge or cloth to remove grease and oil.
- F. Benefit, Super Sheen, Sheila Shine are good for restoration /passivation.
NOTE:
The use of stainless steel cleaners or other such solvents is not
recommended on plastic parts. Warm soap and water will suffice.
STEPS THAT CAN HELP PREVENT RUST ON STAINLESS STEEL:
-
USING THE CORRECT CLEANING TOOLS
Use non-abrasive tools when cleaning your stainless steel products. The stainless steel’s passive layer will not be harmed by soft cloths and plastic scouring pads. Step 2 tells you how to find the polishing marks. -
CLEANING ALONG THE POLISH LINES
Polishing lines or “grain” are visible on some stainless steels. Always scrub parallel to visible lines on some stainless steels. Use a plastic scouring pad or soft cloth when you cannot see the grain. -
USE ALKALINE, ALKALINE CHLORINATED OR NON-CHLORIDE CONTAINING CLEANERS
While many traditional cleaners are loaded with chlorides, the industry is providing an ever increasing choice of non-chloride cleaners. If you are not sure of your cleaner’s chloride content contact your cleaner supplier. If they tell you that your present cleaner contains chlorides, ask if they have an alternative. Avoid cleaners containing quaternary salts as they can attack stainless steel, causing pitting and rusting. -
WATER TREATMENT
To reduce deposits, soften the hard water when possible. Installation of certain filters can remove corrosive and distasteful elements. Salts in a properly maintained water softener can be to your advantage. Contact a treatment specialist if you are not sure of the proper water treatment. -
MAINTAINING THE CLEANLINESS OF YOUR FOOD EQUIPMENT
Use cleaners at the recommended strength (alkaline chlorinated or non- chloride). Avoid build-up of hard stains by cleaning frequently. When boiling water with your stainless steel equipment, the single most likely cause of damage is chlorides in the water. Heating any cleaners containing chlorides will have the same damaging effects. -
RINSE
When using chlorinated cleaners you must rinse and wipe dry immediately. It is better to wipe standing cleaning agents and water as soon as possible. Allow the stainless steel equipment to air dry. Oxygen helps maintain the passivity film on stainless steel. -
HYDROCHLORIC ACID (MURIATIC ACID) SHOULD NEVER BE USED ON STAINLESS STEEL
-
REGULARLY RESTORE/PASSIVATE STAINLESS STEEL
GENERAL MAINTENANCE
RAINSHIELD
When using electrical appliances, basic safety precautions should be followed,
including the following:
CAUTION:
BEFORE PERFORMING SERVICE OR MAINTENANCE MAKE SURE RAINSHIELD IS SECURED IN
OPEN POSITION. USE INSTRUCTIONS AND PHOTOS BELOW TO SECURE RAINSHIELD.
- Remove thumbscrews on the top of each cabinet end.
- Lift rain shield (careful not to pull on any wires)
- Reinstall thumbscrews
- A. The thumbscrews should be put through rain shield holes and fastened into previous position in cabinet end.
CAUTION:
MAKE SURE TOP RAINSHIELD IS CORRECTLY SEATED IN THE OPEN POSITION.
-
Thumbscrew location
-
Louver grill in upright position
WARRANTY INFORMATION (U.S.A. & CANADA ONLY!)
THIS WARRANTY ONLY APPLIES TO UNITS SHIPPED FROM TRUE’S MANUFACTURING
FACILITIES AFTER SEPTEMBER 1, 2015.
THREE-YEAR PARTS & LABOR WARRANTY
TRUE warrants to the original purchaser of every new TRUE refrigerated unit,
the cabinet and all parts thereof, to be free from defects in material or
workmanship, under normal and proper use and maintenance service as specified
by TRUE and upon proper installation and start-up in accordance with the
instruction packet supplied with each TRUE unit. TRUE’s obligation under this
warranty is limited to a period of three (3) years from the date of original
installation or 39 months after shipment date from TRUE, whichever occurs
first. Any part covered under this warranty that are determined by TRUE to
have been defective within three (3) years of original installation or thirty-
nine (39) months after shipment date from manufacturer, whichever occurs
first, is limited to the repair or replacement, including labor charges, of
defective parts or assemblies. The labor warranty shall include standard
straight time labor charges only and reasonable travel time, as determined by
TRUE. Warranty does not cover standard wear parts which include door gaskets,
incandescent bulbs or fluorescent bulbs. Warranty also does not cover issues
caused by improper installation or lack of basic preventative maintenance
which includes regular cleaning of condenser coils.
ADDITIONAL TWO-YEAR COMPRESSOR WARRANTY
In addition to the Three (3) year warranty stated above, TRUE warrants its
hermetically and semi-hermetically sealed compressor to be free from defects
in both material and workmanship under normal and proper use and maintenance
service for a period of two (2) additional years from the date of original
installation but not to exceed five (5) years and three (3) months after
shipment from the manufacturer. Compressors determined by TRUE to have been
defective within this extended time period will, at TRUE’s option, be either
repaired or replaced with a compressor or compressor parts of similar design
and capacity. The two (2) year extended compressor warranty applies only to
hermetically and semi-hermetically sealed parts of the compressor and does not
apply to any other parts or components, including, but not limited to:
cabinet, paint finish, temperature control, refrigerant, metering device,
driers, motor starting equipment, fan assembly or any other electrical
component, etcetera.
404A/134A/HYDROCARBON COMPRESSOR WARRANTY
The two year compressor warranty detailed above will be voided if the
following procedure is not carefully adhered to:
- This system contains R404A, R134A, or R290 refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities. If long exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. For oil amounts and specifications please call TRUE technical service department (855-372-1368). Failure to comply with recommended lubricant specification will void the compressor warranty.
- Drier replacement is very important and must be changed when a system is opened for servicing. An OEM exact replacement should be used. The new drier must also be the same capacity as the drier being replaced.
- Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must be obtained.
WARRANTY CLAIMS
All claims for labor or parts must be made directly through TRUE. All claims
should include: model number of the unit, the serial number of the cabinet,
proof of purchase, date of installation, and all pertinent information
supporting the existence of the alleged defect. In case of warranty
compressor, the compressor model tag must be returned to TRUE along with above
listed information. Any action or breach of these warranty provisions must be
commenced within one (1) year after that cause of action has occurred.
WHAT IS NOT COVERED BY THIS WARRANTY
TRUE’s sole obligation under this warranty is limited to either repair or
replacement of parts, subject to the additional limitations below. This
warranty neither assumes nor authorizes any person to assume obligations other
than those expressly covered by this warranty. NO CONSEQUENTIAL DAMAGES. TRUE
IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING
FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF
REFRIGERATION FAILURE. WARRANTY IS NOT TRANSFERABLE. This warranty is not
assignable and applies only in favor of the original purchaser/user to whom
delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN
MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IMPROPER USAGE. TRUE
ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR
OTHER DAMAGES RESULTING FROM IMPROPER USAGE OR INSTALLATION OR FAILURE TO
CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED
WITH THE UNIT. RELOCATION OF CABINET FOR REPAIR. True is not responsible for
the cost to move a cabinet for any reason from its position of operation on
the customer’s premises to make a warranty repair.
NON OEM PARTS. Use of non OEM parts without manufacturer’s approval will void
cabinet warranty. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING
TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. TRUE is not responsible for
the repair or replacement of any parts that TRUE determines have been
subjected after the date of manufacture to alteration, neglect, abuse, misuse,
accident, damage during transit or installation, fire, flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS. TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR
REPLACEMENT OF FAILED OR DAMAGED
COMPONENTS RESULTING FROM INCORRECT SUPPLY VOLTAGE, THE USE OF EXTENSION
CORDS, LOW VOLTAGE, OR UNSTABLE SUPPLY VOLTAGE. NO IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE: THERE ARE NO OTHER
WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE THREE (3) YEAR PARTS &
LABOR WARRANTY AND THE ADDITIONAL TWO (2) YEAR COMPRESSOR WARRANTY AS
DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE
DESCRIPTION ON THE FACE HEREOF. OUTSIDE U.S. AND CANADA: This warranty does
not apply to, and TRUE is not responsible for, any warranty claims made on
products sold or used outside the United States and Canada. This warranty only
applies to units shipped from True’s manufacturing facilities after September
1, 2015.
Read User Manual Online (PDF format)