EAE Rosa Metal Touch Switches User Manual

October 30, 2023
EAE

EAE Rosa Metal Touch Switches

EAE-Rosa-Metal-Touch-Switches-PRODUCT-IMG

General

Rosa KNX switches offer a wide range of functional flexibility with up to 6 programmable buttons. Rosa switches can be programmed to control lighting, shutter/blind drivers, speakers, make scene calls, and mimic panic buttons. Each button can be programmed independently for a different function.

Device Technology

Button Definitions

  • Programmable Buttons (up to 6 touch buttons)

EAE-Rosa-Metal-Touch-Switches-FIG-1

Connection Diagram

  1. KNX Port Terminal
  2. Programming Button
  3. Programming LED

Technical Data

Operating Voltage Voltage 21V… 30V DC, via the KNX bus
Current drawn from the bus <10mA
Safety Rating Class IP 20, DIN EN 60529

II EN 61140

Connections| KNX| Bus Connection
Operating Temperature| Ambient| -5° C  + 45° C
| Storage| -25° C + 55° C
| Measurement Accuracy| ±0,3 °C
Humidity| Max. Air humidity condensation| 95% no moisture
Dimensions| Front Side| 85 x 85 mm
| Side- Surface mounted part| 11 mm
| Side- Flush mounted part| 19.4 mm
Weight| 73 g|
Box Material| Metal or Glass, polycarbonate|
CE| In accordance with the EMC guideline and low voltage|

Dimensions

EAE-Rosa-Metal-Touch-Switches-FIG-3

Communication Object Table

No. Object Name Function Number of Bits Flags
0 General, operation Active 1 CT
1 Rocker 1, switch On/Off 1 CWT
Rocker 1, shutter Up/Down 1 CWT
Rocker 1, value [0,1] Send 1 CWT
Rocker 1, value [0…255] Send 8 CWT
Rocker 1, value [0…65535] Send 16 CWT
Rocker 1, value [-32768…32768] Send 32 CWT
Rocker 1, value [0…4294967295] Send 64 CWT
Rocker 1, value.temperature Send 64 CWT
TouchButton 1, switch On/Off 1 CWT
TouchButton 1, shutter Up/Down 1 CWT
TouchButton 1, value [0,1] On/Off 1 CWT
TouchButton 1, value [0…255] Send 8 CWT
TouchButton 1, value [0..65535] Send 16 CWT
TouchButton 1, value [- 32768…32768] Send 32 CWT
TouchButton 1, value [0…4294967295] Send 64 CWT
TouchButton 1, value.temperature Send 64 CWT
2 Rocker 1, dimming Send 4 CWT
Rocker 1, shutter Stop/Lamella Adj 1 CWT
TouchButton 1, dimming Send 4 CWT
TouchButton 1, shutter Stop/Lamella Adj 1 CWT
TouchButton 1, value [0,1] On/Off 1 CWT
TouchButton 1, value [0…255] Send 8 CWT
TouchButton 1, value [0…65535] Send 16 CWT
TouchButton 1, value [- 32768…32768] Send 32 CWT
TouchButton 1, value [0…4294967295] Send 64 CWT
TouchButton 1, value.temperature Send 64 CWT
3 Rocker 1, shutter Top Position 1 CWT
Rocker 1, status Top Position 1 CWT
TouchButton 1, shutter Top Position 1 CWT
TouchButton 1, status Top Position 1 CWT
4 Rocker 1, shutter Bottom Position 1 CWT
TouchButton 1, shutter Bottom Position 1 CWT

Parameters and Communication Objects

General
General parameters include;

  • In Operation (Device Alive) Function
  • Telegram Limit Function
  • Rocker Count
  • Light Duration Of Status Indication Function
  • LED Duration of Touch Feedback Function
  • Navigation LED Brightness Function

EAE-Rosa-Metal-Touch-Switches-FIG-4

Parameters

Parameter Settings Description
Enable In Operation Enable/ Disable In operation can be used to ensure

that the device is alive and

connected to the KNX line.

In Operation Bit| Off/ On| Visible when “Enable In Operation” is enabled. Bit value to send as device alive

operation

In Operation Send Interval[sec]| 0… 300 …65535| Visible when “Enable In Operation” is enabled. The cyclic time period for sending in the operation

bit

Enable Telegram Limit| Enable /Disable| Limits the number of telegrams to send in the certain time period
Telegram Limit Period Duration| 50ms , 100ms, …, 30s, 1min| Visible when “Enable Telegram Limit” is enabled. Time period to check

telegram numbers

Maximum Telegram Count in Period| 1.. 100 …255| Visible when “Enable Telegram Limit” is enabled. The maximum number of telegrams to send in telegram limits the period duration
Light Duration of Status Indication| 0,75s , 2.25s, 3.25s| LEDs on duration when status LEDs are used as operation indication with rocker or touch

buttons.

Rocker Count| 1, 2 , 3, 4, 5, 6| The number of rockers should be selected compatible with the device to be able to use rockers and

touch buttons correctly.

Duration of Touch Feedback LED (after release) [0…65535 ms]| 0 …65535| Touch Feedback LEDs lighting duration after release.
Navigation Light Brightness [0…100%]| 0… 100%| Navigation LED brightness value

Communication Objects

No Object Name Function Data Type Flags
0 General – In operation Active 1 Bit

DPT 1.002

| CT

In operation value (0,1) selected through the “In operation bit,” parameter will be sent via the group address which is linked to this communication object.

Rockers and Touch Buttons
A total number of rockers can be selected through the “Rocker Count” parameter in the “General” tab. Buttons on the thermostat can be used as rockers or touch buttons. Select the desired operation from the “Rocker N” (N: Rocker number) tab (Figure 2). If rockers are configured as touch buttons, 2 touch button tabs will be visible under the “Rocker N” tab (Figure 3). Both rockers and touch buttons have 5 functions;

  • no function
  • switch
  • switch and dim
  • shutter
  • value operation

EAE-Rosa-Metal-Touch-Switches-FIG-5

Rockers
A number of rockers should be selected in the “General” tabs in parameters and should be chosen as compatible with the device that will be configured. Rockers are numbered from top to bottom. Each Rocker contains 2 touch buttons separately. Rockers can be configured as 4 different operations and 1 function to disable rocker (No Function). Operation selection can be configured with the “Rocker Function” parameter. Every function enables different parameters and communication objects that will be explained in the following chapters.

Parameter Setting Description
Rocker Operation Rocker /2 Touch Button Selects the function of the

rocker
Rocker Function| No Function| Disables the rocker
Switch| Rocker can be used to send on/off telegrams. (For more information Chapter 4.2.1.1)
Switch and Dim| Rocker can send on/off and dimming telegrams. (For more information Chapter

4.2.1.2)

Shutter| Rocker can control shutter, Venetian blind, blind, roller and

awning. (For more information Chapter 4.2.1.3)

Value Operation| Rocker buttons can send predefined values from different data types. (For more

information Chapter 4.2.1.4)

Rockers also have status LEDs which can be configured to indicate the state of the operation that is configured.

Switch
Selecting “Switch” as “Rocker Function“ enables sending 1-bit On(1)/Off(0) telegrams to the group address that is linked to the respective communication object. Status LEDs can be configured to notify the current status of operation directly with buttons or using communication objects for confirmation to show the current status.

EAE-Rosa-Metal-Touch-Switches-FIG-6

Parameters

Parameter Setting Description
Mode of Buttons Left Button On Right Button Off

Left Button Off Right Button On

| Select which button is the ON button and which button is the OFF button
Function of LED| LED permanently Off| LED always Off
LED permanently On| LED always On
Status Indication| The Status LED of the last touched rocker button is on, the other rocker button is off. If the “Separate Comm Object” parameter is selected as “Enable” status LEDs will wait for confirmation from the communication object

before changing state.

Inverted Status Indication| The status LED of the last touched rocker button is off, the other rocker button is on. If the “Separate Comm Object” parameter is selected as “Enable” status LEDs will wait for confirmation from the communication

the object before changing state.

Operation Indication| The status LED of the touched rocker button will be on for the time period selected at the “Light Duration of LED” parameter at

“General” tab.

Separate Comm Object| Enable/ Disable| Only visible when “Function of LED” is selected as “Status Indication” or “Inverted Status Indication”. This communication object is the input of confirmation for status LEDs. If selected “Enable” the respective communication object should be linked to an appropriate

group address

Communication Objects

No Object Name Function Data Type Flags
1 Rocker1 – Telegr. switch On/Off 1 bit

DPT 1.001

| CWT
| On/Off telegrams will be sent to the group address that is linked to this communication object.
3| Rocker1 – Status Comm. Obj.| On/Off| | 1 bit

DPT 1.002

| CWT
| Confirmation for On/Off switch telegrams will be received from this communication object. If these communications objects are visible, they must link to an appropriate group address. Otherwise, status LEDs will not function correctly. If status confirmation is not to be used the communication object should be disabled by “Separate Comm Object”

parameter.

Switch and Dim

EAE-Rosa-Metal-Touch-Switches-FIG-7

Rockers can be configured with switching and dimming capabilities. When configured as “Switch and Dim” rocker buttons will have two modes switch mode and dim mode. When the rocker button touched shorter than the time period specified in the “Long Touch Duration” parameter, the rocker button will act as a switch. In switch mode, rocker buttons will behave as normal switches as explained in Chapter 4.1.1. When the rocker buttons touched longer than “Long Touch Duration” rocker will enter “Dim mode”. Dimming capability can be used in two different types “Start Stop” and “Step Wise”. Which type to use can be configured in the “Dimming Type” parameter.
Dimming – Start Stop Type
When the rocker button is touched (and not released) and the touched duration exceeds “Long Touch Duration” time “Increase, %100”(When the on button is touched) or “Decrease,%100”(When the off button is touched) dimming level will be sent using respective communication object. When the button is released “Increase, Break” or “Decrease, Break” value will be sent to stop the dimming operation.
Dimming – Step Wise Type
When the rocker button is touched (and not released) and the touched duration exceeds the “Long Touch Duration” time, a step value level configured in the “Step Value” parameter will be sent using the respective communication object. Until the button is released same step value will be sent periodically with a time interval defined in “Step Send Interval”.

Parameter Setting Description
Mode of Buttons Left Button Brighter(On) Right Button Darker(Off)

/ Left Button Brighter(Off) Right Button Darker(On)

| Select which rocker button is on the button and which rocker button is off button
Long Touch Duration| 300ms/ 400ms/ 500ms/ 600ms/ 800ms /

1s / 1.2s / 1.5s/ 2s / 3s / 4s / 5s / 6s / 7s

/ 8s / 9s / 10s

| Time interval to switch from “switch mode” to “dimming mode”.
Dimming Type| Start to Stop / Step Wise| Select dimming type. (Chapter 4.2.1.2)
Step Value| %100 / %50 / %25 / %12.5 / %6.25 /

%3.13 / % 1.56

| Visible when dimming type is Step Wise. Selects the dimming resolution that will be sent at every “Step

Send Interval”.

Step Send Interval| 300ms/ 400ms/ 500ms/ 600ms/ 800ms / 1s / 1.2s / 1.5s/ 2s / 3s / 4s / 5s / 6s / 7s / 8s / 9s / 10s| Visible when dimming type is Step Wise. Selects the time interval to

send dimming increase/decrease values

Function of LED| LED Permanently Off| LED always off
LED Permanently On| LED always on
Status Indication| The status LED of the last touched rocker button is on, another rocker button is off. If the “Separate Comm Object” parameter is selected as “Enable” status LEDs will wait for confirmation

from communication object before changing state.

Inverted Status Indication| The status LED of the last touched rocker button is off, another rocker button is on. If the “Separate Comm Object” parameter is selected as “Enable” status LEDs will wait for confirmation

from communication object before changing state.

Operation Indication| The status LED of the touched rocker button will be on for the time period

selected at the “Light Duration of LED” parameter at the “General” tab.

Separate Comm Object| Enable / Disable| Only visible when “Function of LED” is selected as “Status Indication” or “Inverted Status Indication”. This communication object is the input of confirmation for status LEDs. If selected as “Enable” the respective communication object should be linked to an

appropriate group address

Communication Objects

No Object Name Function Data type Flags
1 Rocker1 – switch On/Off 1 bit

DPT 1.001

| CWT
On/Off telegrams will be sent to the group address that is linked to this communication object.
2| Rocker1 – dimming| Dim| 4 bit

DPT 3.007

| CWT
Dimming values will be sent to the group address that is linked to this communication object.
3| Rocker1-Status

Comm. Obj.

| On/Off| 1 bit

DPT 1.002

| CWT
Confirmation for On/Off switch telegrams will be received from this communication object. If these communication objects are visible, they must link to an appropriate group address. Otherwise, status LEDs will not function correctly. If status confirmation is not to be used the communication object should be

disabled by the “Separate Comm Object” parameter.

Shutter

EAE-Rosa-Metal-Touch-Switches-FIG-8

Selecting “Shutter” for “Rocker Operation” enables shutter operation for rocker buttons. Shutter functions can be configured to control two different shutter operations “Shutter/Venetian Blind” function or the “Blind/Roller/Awning” function.

Shutter/Venetian Blind
Firstly, select which rocker button is used for the “up” operation, and which rocker button is used for “down” operation by the “Mode of Buttons” parameter. Both buttons have two functions as “short touch” function and the “long touch” function, “Long Touch Duration” parameter configures the limit time period for the “long touch” operation. “Long Touch” will be used to move the blind upwards or downwards. “Short touch” has two different functions whether the blind is moving or not. When the blind is moving “short touch” acts as a stop button that stops the blind’s movement, when the blind is not moving “short touch” function is used to adjust the lamella position.

| Short Touch| Long touch
---|---|---
Up Button – Blind Moving| Stop| Up
Down Button – Blind Moving| Stop| Down
Up Button – Blind Stopped| Lamella Down| Up
Down Button – Blind Stopped| Lamella Up| Down

EAE KNX Rosa Switch

When the “Up Button” long touched “Up” telegram will be transmitted using the “Rocker1 – Shutter UP/DOWN” communication object and the shutter will start moving upwards until it reaches the “Top Position” or “STOP” telegram transmitted using “Rocker1 – STOP/Lamella Adj.” communication object by short touching “Up Button” or “Down Button”. When the “Down Button” long touched “Down” telegram will be transmitted using the “Rocker1 – Shutter UP/DOWN” communication object and the shutter will start moving downwards until it reaches the “Bottom Position” or “STOP” telegram transmitted using the “Rocker1 – STOP/Lamella Adj.” communication object by short touching “Up Button” or “Down Button”. When the blind is not moving “Up Button” and “Down Button” operate as lamella adjustment and respective telegrams will be sent using the “Rocker1-STOP/Lamella Adj.” communication object.

Blind/Roller/Awning Function
Selecting the “Control Type” parameter as “Blind/Roller/Awning” disables lamella adjustment functions of rocker buttons. In this control type, when “Up Button” is touched “Up” telegram will be sent using the “Rocker1 – shutter. UP/DOWN” communication object and touched again while the blind is moving “STOP” telegram will be sent using the “Rocker1 – STOP/Lamella adj.” communication object. When the “Down Button” touched “DOWN” the telegram will be sent using the “Rocker1 – shutter. UP/DOWN” communication object and touched again while the blind is moving “STOP” telegram will be sent using the “Rocker1 – STOP/Lamella adj.” communication object.

Parameters

Parameter Setting Description
Mode of Buttons Left Up Right Down

Left Down Right Up

| Select which rocker button is the “Up Button” and which rocker

the button is the “Down Button”.

Control Type| Shutter/Venetian Blind

Blind/Roller/Awning

| Selects the control type of blinds. The shutter/Venetian Blind function includes “Lamella Control” and the Blind/Roller/Awning function does not include “Lamella Control”.
Function of LED| LED Permanently Off| LED always off
LED Permanently On| LED always on
Status Indication| Visualize the blind’s state using status LEDs of up and down buttons. * [5]
Operation Indication| The status LED of the touched rocker button will be on for the time period selected at “Light Duration of LED”

parameter at the “General” tab.

Long Touch Duration| 300ms/ 400ms/ 500ms/ 600ms/

800ms / 1s / 1.2s / 1.5s/ 2s /

3s / 4s / 5s / 6s / 7s / 8s / 9s / 10s

| Time interval to switch from short touch to long touch

*[5] LED Function – Status Indication
Status indication operates the same way for “Shutter/Venetian Blind” and “Blind/Roller/Awning”. LED’s status is respective to the blind’s state is given below.

| Up Button – Status LED| Down Button – Status LED
---|---|---
Moving upward| Blink| Off
Moving downward| Off| Blink
At top position| On| Off
At bottom position| Off| On
Stop between the top – bottom| Off| Off

When “Function of Led” is selected as “Status Indication”, “Top Position” and “Bottom Position” communication objects given below must be linked to the appropriate group addresses for the status LEDs to function correctly.

Communication Objects

No Object Name Function Data Type Flags
1 Rocker1-shutter

UP/DOWN

| Up/Down| 1 bit

DPT 1.008

| CWT
This communication object will be used to start a blind movement.
2| Rocker1 –

STOP/Lamella adj.

| Stop/Lamella adj.| 1 bit

DPT 1.002

| CWT
When the “Control Type” parameter is “Shutter/Venetian Blind” this communication object is used to stop

movement of the blind and adjust lamella position, otherwise when the “Control Type” parameter is “Blind/Roller/Awning” only used for stopping blind movement.

3| Rocker1-Top Position| True/False| 1 bit

DPT 1.002

| CWT
This communication object should be linked to an appropriate group address that will be used to detect whether the blind is at the “Top Position” (True) or not (False).
4| Rocker1-Bottom Position| True/False| 1 bit

DPT 1.002

| CWT
This communication object should be linked to an appropriate group address that will be used to detect whether the blind is at the “Bottom Position” (True) or not (False).

Value Operation

EAE-Rosa-Metal-Touch-Switches-FIG-9

Rocker buttons can be configured to send predefined values from different data types. Values selected for both rocker buttons will be transmitted over the same communication object.

Parameters

Parameter Setting Description
Function of Led LED Permanently Off LED always off
LED Permanently On LED always on
Operation Indication The status LED of the touched rocker button will be on

for the time period selected at “Light Duration of LED”

parameter at the “General” tab.

Data Type| No Reaction

1-bit value

1byte value [0…255] Percent value [%0…%100] 2 byte value [- 32768…32767] 2 byte

value [0…65535]

4-byte value [floating point]

4-byte value [0…4294967295]

| Select data type.
Left Button of the Rocker
Sent value| 0 /1| Visible when “Data Type” is selected as “1-bit value”.
Transmitted value [0…255]| 0 …255| Visible when “Data Type” is selected as “1-byte value”.
Send percent value [%0…%100]| 0… 80 …100| Visible when “Data Type” is selected as “percent value”.
Transmitted value [- 32768…32767]| -32768… 0 …32767| Visible when “Data Type”

selected as “2-byte value [- 32768…32767]”.

Transmitted value [0…65535]| 0 …65535| Visible when “Data Type” is selected as “2-byte value [0…65535]”.
Float decimal| -128… 0 …127| Visible when “Data Type” selected

as “4 byte value [floating point]”.

Float rational| 0 …99| Visible when “Data Type”

selected as a “4-byte value [floating point]”.

---|---|---
Transmitted value [0…4294967295]| 0 …4294967295| Visible when “Data Type” is selected as “4-byte value [0…4294967295]”.
Right Button of Rocker – Operate the same way as the Left Button of the Rocker

Communication Objects

No Object Name Function Data type Flags
1 TouchButton1 – value [0,1] True/False 1 bit DPT 1.002 CWT

Enabled when “Data Type” is selected as “1-bit value”
TouchButton1– value [0…255]| Send| 1 byte DPT 5.010| CWT
Enabled when “Data Type” is selected as “1byte value [0…255]”
TouchButton1– value [0…255]| Send| 1 byte DPT 5.001| CWT
Enabled when “Data Type” is selected as “Percent value [%0…%100]
TouchButton1- value [-32768…32767]| Send| 2 byte DPT 8.001| CWT
Enabled when “Data Type” is selected as “2-byte value [-32768…32767]”
TouchButton1- value [0…65535]| Send| 2 byte DPT 7.001| CWT
| Enabled when “Data Type” is selected as “2-byte value [0…65535]”
TouchButton1- value[temperature]| Send| 4 byte DPT 14.068| CWT
Enabled when “Data Type” is selected as “4-byte value [floating point]
TouchButton1-value [0…4294967295]| Send| 4 byte DPT 12.001| CWT
Enabled when “Data Type” is selected as “4-byte value [0…4294967295]”
2| TouchButton1-long – value [0,1]| True/False| 1 bit DPT 1.002| CWT
Enabled when “Long Touch Data Type” is selected as “1-bit value”
TouchButton1-long – value [0…255]| Send| 1 byte DPT 5.010| CWT
Enabled when “Long Touch Data Type” is selected as “1byte value [0…255]”
TouchButton1– value [0…255]| Send| 1 byte DPT 5.001| CWT
Enabled when “Long Touch Data Type” is selected as “Percent value [%0…%100]
TouchButton1 – long- value [-32768…32767]| Send| 2 byte DPT 8.001| CWT
Enabled when “Long Touch Data Type” is selected as “2-byte value [-32768…32767]”
TouchButton1- long -value [0…65535]| Send| 2 byte DPT 7.001| CWT
Enabled when “Long Touch Data Type” is selected as “2-byte value [0…65535]”
TouchButton1- long – value[temperature]| Send| 4 byte DPT 14.068| CWT
Enabled when “Long Touch Data Type” is selected as “4-byte value [floating point]
TouchButton1- long – value [0…4294967295]| Send| 4 byte DPT 12.001| CWT
Enabled when “Long Touch Data Type” is selected as “4-byte value [0…4294967295]”

Touch Buttons

A number of rockers should be selected in the “General” tabs in parameters and should be chosen as compatible with the device that will be configured. Touch buttons are numbered from top to bottom – right to left, topmost right touch button as touch button 1, near it is touch button 2, and so on. Touch buttons can be configured as 4 different operations and 1 function to disable the touch button (No Function). Operation selection can be configured from the “Touch Button N” (N: Touch button number) tab, visible when “Rocker Operation” is selected as “2 Touch Buttons”. Every function enables different parameters and communication objects that will be explained in the following chapters.

Parameter Setting Description
Touch Button Function No Function Disables the touch button
Switch Touch buttons can be used to send

on/off telegrams. (For more information Chapter 4.2.2.1)

Switch and Dim| Touch buttons can send on/off and

dimming telegrams. (For more information Chapter 4.2.2.2)

Shutter| The touch button can control the shutter, Venetian blind, blind, roller, and awning. (For more information

Chapter 4.2.2.3)

Value Operation| The touch button can send predefined values from different data types.

(Refer to Section 4.2.2.4)

Touch buttons also have status LEDs which can be configured to indicate the state of the operation that is configured.

Switch

EAE-Rosa-Metal-Touch-Switches-FIG-10

Selecting “Switch” as “Touch Button Function“ enables sending 1-bit On(1)/Off(0) telegrams to the group address that is linked to the respective communication object. Touching and releasing buttons can be assigned to different commands (On, Off, Toggle, and No Command). Status LEDs can be configured to notify the current status of operation directly with buttons or using communication objects for confirmation to show the current status.

Parameters

Parameter Setting Description
Command on Touch On / Off / Toggle / No command Selects button function

when button touched.
Command on Release| On / Off / Toggle / No command| Selects button function when button released.
Function of LED| LED permanently Off| LED always Off
LED permanently On| LED always On
Status Indication| Last transmitted command “on” -> LED on Last transmitted command “off” -> LED off If “Separate Comm Object” is enabled, status LEDs will  wait for

confirmation before changing status.

Inverted Status Indication| Last transmitted command “on” -> LED off Last transmitted command “off” -> LED on If “Separate Comm Object” is enabled, status LEDs  will  wait for

confirmation before changing status.

Operation Indication| The status LED of the touched touch button will be on for the time period selected at the “Light Duration of LED” parameter in the “General” tab.

The last transmitted command value has no effect to the status-led operation.

Separate Comm Object| Enable/ Disable| Only visible when “Function of LED” is selected as “Status Indication” or “Inverted Status Indication”. This communication object is the

input of confirmation for status LEDs. If selected “Enable” the respective communication object should be linked

to an appropriate group address.

Communication Objects

No Object Name Function Data Type Flags
1 TouchButton1 switch 1 bit

DPT 1.001

| CWT
On/Off telegrams will be sent to the group address that is linked to this communication object.
3| TouchButton1| Status Comm.Obj.| 1 bit

DPT 1.002

| CWT
Confirmation for On/Off switch telegrams will be received from this communication object. If these communications objects are visible, it must link to an appropriate group address. Otherwise, status LEDs will not function correctly. If status confirmation is not to be used the communication object should be

disabled by the “Separate Comm Object” parameter.

Switch and Dim

EAE-Rosa-Metal-Touch-Switches-FIG-11

When touch button function is selected as “Switch and Dim” the touch button can be configured in three different ways to control brightness value.

| Short Touch| Long touch
---|---|---
Darker(Short Touch Off)| Off (%0)| Decrease, (%XX)
Brighter(Short Touch On)| On(%100)| Increase,(%XX)
Darker/Brighter(Short Touch Toggle)| Toggle between Darker/Brighter| Decrease, (%XX) / Increase,(%XX)

%XX values can have different values relative to the “Dimming Type” parameter. The “Dimming Type”  parameter allows two different types of dimming functionality “Start Stop” and “Step Wise”.

Dimming – Start Stop Type
When the touch button is touched (and not released) and the touched duration exceeds “Long Touch Duration” time “Increase, %100” (When the button in Brighter mode) or “Decrease, %100” (When the button in Darker mode) dimming level will be send using respective communication object. When the button released “Increase, Break” or “Decrease, Break” value will be sent.

Dimming – Step Wise Type
When the touch button is touched (and not released) and the touch duration exceeds the “Long Touch Duration” time, a step value level configured in the “Step Value” parameter will be sent using the respective communication object. If the button mode is “Darker”, “Decrease, % [Step Value]”, else button mode is “Brighter”, “Increase, % [Step Value]” values will be sent. Until the button is released same step value will be sent periodically with a time interval defined in “Step Send Interval”.

Parameters

Parameter Setting Description
Dim Operation Darker (Short Touch Off) Brighter (Short Touch On)

Darker/Brighter (Short Touch

Toggle)

| Select the touch button dim operation. (For more information Chapter 4.2.2.2)
Long Touch Time| 300ms/ 400ms/ 500ms/ 600ms/| Time interval to switch from
| 800ms /| “switch/toggle mode” to “dimming
| 1s / 1.2s / 1.5s/ 2s / 3s / 4s / 5s / 6s /| mode”.
| 7s|
| / 8s / 9s / 10s|
Dimming Type| Start to Stop / Step Wise| Select dimming type. ( For more information Chapter 4.2.2.2)
Step Value| %100 / %50 / %25 / %12.5 / %6.25 /| Visible when the dimming type is Step
| %3.13 / % 1.56| Wise. Selects the dimming resolution
| | that will be sent at every “Step
| | Send Interval”.
Step Send Interval| 300ms/ 400ms/ 500ms/ 600ms/| Visible when the dimming type is Step
| 800ms /| Wise. Selects the time interval to
| 1s / 1.2s / 1.5s/ 2s / 3s / 4s / 5s / 6s /| send dimming increase/decrease
| 7s

/ 8s / 9s / 10s

| values
Function of LED| LED Permanently Off| LED always off
LED Permanently On| LED always on
Status Indication| Last transmitted command “on” -> LED on Last transmitted command “off” -> LED off If “Separate Comm Object” is enabled, status LEDs will  wait for

confirmation before changing status.

Inverted Status Indication| Last transmitted command “on” -> LED off Last transmitted command “off” -> LED on If “Separate Comm Object” is enabled, status LEDs  will  wait for

confirmation before changing status.

Operation Indication| The status LED of the touched touch button will be on for the time period selected at “Light Duration of LED”

parameter at the “General” tab.

Separate Comm Object| Enable / Disable| Only visible when “Function of LED” is selected as “Status Indication” or “Inverted Status Indication”. This communication object is the input of confirmation for status LEDs. If selected “Enable” the respective communication object should be linked to an appropriate group

address.

Communication Objects

No Object Name Function Data type Flags
1 TouchButton1 – switch On/Off 1 bit

DPT 1.001

| CWT
On/Off telegrams will be sent to the group address that is linked to this communication object.
2| TouchButton1 – dimming| Dim| 4 bit

DPT 3.007

| CWT
Dimming values will be sent to the group address that is linked to this communication object.
3| TouchButton1- Status

Comm. Obj.

| On/Off| 1 bit

DPT 1.002

| CWT
Confirmation for On/Off switch telegrams will be received from this communication object. If these communications objects are visible, it must link to an appropriate group address. Otherwise, status LEDs will not function correctly. If status confirmation is not to be used the communication object should be

disabled by the “Separate Comm Object” parameter.

Shutter

EAE-Rosa-Metal-Touch-Switches-FIG-12

Selecting “Shutter” for “Touch Button Function” enables shutter operation for touch buttons. Shutter functions can be configured to control two different shutter operations “Shutter/Venetian Blind” function or the “Blind/Roller/Awning” function. In both functions touch button can be configured as 3 different button functions; Up, Down, and Toggle. When the touch button is selected as up or down, that button can only move the blind and lamella to the configured direction. For example, if configured as up button, the touch button can be used to move the blind up and adjust the lamella down. If the touch button configured as a toggle button, a single button can be used to move the blind up–down and adjust the lamella up–down.

Shutter/Venetian Blind Function
When “Controller Type” is configured as “Shutter/Venetian Blind”, lamella operations of blind control will be enabled as the “short touch” function of the touch button. Also, the “Button Function” parameter enables the use of the touch button 3 different ways;

Up: “Long Touch” moves the blind upwards; “Short Touch” operates two different ways, short touched while the blind is moving, stops the blind, and short touched while the blind is not moving adjusts the lamella position down.
Down: “Long Touch” moves the blind downwards; “Short Touch” operates two different ways, short touched while the blind is moving, stops the blind, short touched while the blind is not moving adjusts the lamella position up.

Toggle: “Long Touch” moves the blind upwards or downwards toggling the last “Long Touch” action. For example, if the last state was up, when the touch button is long touched, it will send a “Down” telegram. Every time the touch button is long touched it will toggle its last state. If the touch button is short-touched while the blind is moving upward or downward “Short Touch” will stop the blind, if the blind is not moving “Short Touch” will adjust the lamella. Lamella adjustment will operate respective to the last state, for example, if the last “Long Touch” action was up, then lamella will be adjusted down when touch button short touched and if the last “Long Touch” action was down, then lamella will be adjusted up when touch button short touched.

Blind/Roller/Awning Function
When “Controller Type” is configured as “Blind/Roller/Awning Function” lamella operations of blind control will be disabled and “short touch” will only stop the movement of the blind. “Button Function”the  parameter enables the use of the touch button 3 different ways;

Up: “Long Touch” moves the blind upwards; “Short Touch” stops the blind.
Down: “Long Touch” moves the blind downwards; “Short Touch” stops the blind.
Toggle: “Long Touch” action moves the blind upwards or downwards toggling the last “Long
Touch” action. For example, if the last state was up, when the touch button is long touched it will send a “Down” telegram. Every time touch button is long touched it will toggle its last state. “Short Touch” stops the blind whether it’s moving upwards or downwards

Parameters

Parameter Setting Description
Touch Button Function Up / Down / Toggle Chapter 4.2.2.3
Control Type Shutter/Venetian Blind

Blind/Roller/Awning

| Selects the control type of blinds. The shutter/Venetian Blind function includes “Lamella Control” and the Blind/Roller/Awning function does not include “Lamella

Control”.

Function of LED| LED Permanently Off| LED always off
| LED Permanently On| LED always on
| Status Indication| Visualize the blind’s state using

status LEDs of up and down buttons. * [6]

| Operation Indication| The status LED of the touched rocker button will be on for the time period selected at the “Light Duration of LED” parameter at

“General” tab.

Long Touch Duration| 300ms / 400ms/ 500ms/ 600ms/ 800ms / 1s / 1.2s / 1.5s/ 2s /

3s / 4s / 5s / 6s / 7s / 8s / 9s /

10s

| Time interval to switch from short touch to long touch

Communication Objects

*[6] LED Function – Status Indication operates the same way for “Shutter/Venetian Blind” and “Blind/Roller/Awning”. LEDs status respective to the blind’s state and “Button Function” configuration given below;

| Up Mode| Down Mode| Toggle Mode
---|---|---|---
Moving upward| Blink| Off| Blink
Moving downward| Off| Blink| Blink
At top position| Off| Off| Off
At bottom position| Off| Off| Off
Stop between top – bottom| Off| Off| Off

When “Function of Led” is selected as “Status Indication”, “Top Position” and “Bottom Position” communication objects given below must be linked to the appropriate group addresses for the LEDs to function correctly.

Value Operation

EAE-Rosa-Metal-Touch-Switches-FIG-13

Touch button can be configured to send predefined values from different data types. Additionally, a long touch request can be enabled to be used as a secondary value operation.

Parameters

Parameter Setting Description
Function of Led LED Permanently Off LED always off
LED Permanently On LED always on
Operation Indication The status LED of the touched rocker button will be on

for the time period selected at “Light Duration of LED”

parameter at the “General” tab.

Data Type| No Reaction

1-bit value

1byte value [0…255] Percent value [%0…%100]

2 byte value [-32768…32767] 2 byte value [0…65535]

4-byte value [floating point]

4-byte value [0…4294967295]

| Select data type.
Sent value| 0 /1| Visible when “Data Type” is selected as “1-bit value”.
Transmitted value [0…255]| 0 …255| Visible when “Data Type” is selected as “1-byte value”.
Send percent value [%0…%100]| 0… 80 …100| Visible when “Data Type” is selected as “percent value”.
Transmitted value [-32768…32767]| -32768… 0 …32767| Visible when “Data Type” is selected as “2-byte value [- 32768…32767]”.
Transmitted value [0…65535]| 0 …65535| Visible when “Data Type” is selected as a “2-byte value [0…65535]”.
Float decimal| -128… 0 …127| Visible when “Data Type”

selected as a “4-byte value [floating point]”.

Float rational| 0 …99| Visible when “Data Type” is selected as “4-byte value [floating point]”.
Transmitted value [0…4294967295]| 0 …4294967295| Visible when “Data Type” is selected as “4-byte value [0…4294967295]”.
Long Touch Request| No / Yes| Enable/Disable long touch duration
Long Touch Duration| 100ms / 1s / 10s / 1min / 10min| The select time period for long touch operation
Long Touch Data Type| No Reaction

1-bit value

1byte value [0…255] Percent value [%0…%100]

2 byte value [-32768…32767] 2 byte value [0…65535]

4-byte value [floating point]

4-byte value [0…4294967295]

| Select data type.
Sent value| 0 /1| Visible when “Long Touch Data

Type” selected as “1-bit value”.

Transmitted value [0…255]| 0 …255| Visible when “Long Touch Data

Type” selected as “1 byte value”.

Send percent value [%0…%100]| 0… 80 …100| Visible when “Long Touch Data

Type” selected as “percent value”.

EAE KNX Rosa Switch

Transmitted value [- 32768…32767]| -32768… 0 …32767| Visible when “Long Touch Data Type” selected as “2 byte

value [- 32768…32767]”.

---|---|---
Transmitted value [0…65535]| 0 …65535| Visible when “Long Touch Data Type” selected as “2

byte value [0…65535]”.

Float decimal| -128… 0 …127| Visible when “Long Touch Data Type” selected as “4

byte value [floating point]”.

Float rational| 0 …99| Visible when “Long Touch Data Type” selected as “4

byte value [floating point]”.

Transmitted value [0…4294967295]| 0 …4294967295| Visible when “Long Touch Data Type” is selected as a “4-byte value [0…4294967295]”.

www.eaetechnology.com.