EAE Technology Mona Black DND Mur R1.1 Horizontal Display Instruction Manual

June 1, 2024
EAE Technology

Installation Manual MONA DND-MUR
EAE KNX MONA Series
MONA DND-MUR R1.1

Device Description

The Mona series DND MUR display, where you can easily see whether your guests are in the room, consists of a glass touch screen and includes room number, hotel logo, occupancy, Do Not Disturb, Make Up Room indicators and doorbell button.

  • Monoblock glass design
  • Customizable Logo
  • Built-in touch buzzer button
  • Suitable for flush mounting
  • Device is powered by KNX
  • Physical KNX Doorbell output
  • 2 x Relay Output
  • Colourful LED Indicators
  • The occupancy information is taken from KNX

Operation and Display

Front Side Back Side
1- Logo 1- KNX Bus
2- Room No 2- Physical address prog. button
3- Buzzer Button 3- Physical address prog. LED
4- MUR Indicator 4- 30V DC (KNX AUX)
5- Occupancy LED

6- DND Indicator

Technical Data

Protection Type IP20  (IP65  optional) EN 60529
Safety Rating II EN 61140
Connections KNX Bus
KNX AUX Bus Terminal

AUX Terminal
Power Supply| Voltage
Current drawn from KNX bus
Current drawn from KNX aux| 21V… 30V DC, KNX
< 10 mA
< 60 mA
Operating
Elements| LED (red)
LED (RGB)|    Addr Prog. LED
Status LEDs
Operating
Temperature| Ambient| -5° C   + 45° C
Humidity| Max. Air Humidity| 95% no moisture
Dimensions| Front Side
Side- Surface mounted parSide- Flush mounted part| 120 x 195 mm
13,2 mm
20.8 mm
Box Material| Surface : Glass
Flush Mounted Part : Polycarbonate
Color| Surface : Black or White
Flush Mounted Part : Black
CE| In accordance with the EMC guideline and low voltage directives

Installation

Installation of the product is done with metal flange. It is fixed to the junction box by using screws. The switch has magnets and should be positioned buttons downwards. The device will stick on flange by magnetization.

Commissioning

Device default physical address is 15.15.255. Determination of the physical address and setting of parameters are actualized with Engineering Tool Software (ETS4 or higher). “.knxprod” file must be imported to the ETS. (http://www.eaetechnology.com/)
A detailed information about parameter configuration can be found in Product Manual of device.
Installation and commissioning of device may only be implemented by trained electricians. The relevant standards, directives, regulations and instructions must be observed when planning and implementing the electrical installation.

-Protect the device against moisture, dirt and damage during transport, storage and operation!
-Do not operate the device out of the specified technical data which is stated.
-The device may only be operated in closed enclosures (Distribution boards)

Cleaning

If device becomes dirty, only a dry cloth can be used for cleaning. İt isnot suitable to use wet cloths, caustics and solvents.

© EAE Technology
www.eaetechnology.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EAE Technology User Manuals

Related Manuals