Eterna KFLATDL12 Colour Temperature Selectable Recessed Flat LED Downlights Instruction Manual

June 10, 2024
Eterna

Eterna KFLATDL12 Colour Temperature Selectable Recessed Flat LED

Downlights

Product Information

The LED Lamp is available in three different wattages: 12W, 18W, and 24W. It has a rated luminous flux of 1130-1170/1700-1780/2250-2280 lm and a nominal life time of 40,000 hours. The lamp is available in Warm White, Cool White, and Daylight White colors with a color temperature of 3000/4000/6000K and a color rendering index of 80 Ra. The lamp is not dimmable and has a nominal beam angle of 120 degrees. It has a displacement factor of 0.979-0.972 and a lumen maintenance factor of 80 at the end of the nominal life.

Product Usage Instructions

These instructions are provided as a guideline to assist qualified electricians in installing the Colour Temperature Selectable Recessed Flat LED Downlights:

  • Check the pack and make sure you have all the parts listed on the front of the booklet. If not, contact the outlet where you bought the product.
  • This light fitting must be installed by a competent person in accordance with the current building and IEE wiring regulations.
  • Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.
  • Ensure that the fitting is fit for the purpose for which it is intended. Eterna Lighting cannot accept any liability for loss, damage, or premature failure resulting from inappropriate use.
  • These downlights are not suitable for accent lighting.

For more information on replaceability and recycling, visit the Eterna Lighting website. If you have any technical or sales queries, you can contact Eterna Lighting via email at sales@eterna-lighting.co.uk or technical@eterna-lighting.co.uk. The product is made in China.

Pack contents

  • 1 x Fitting
  • 1 x Driver

LED LAMP SPECIFICATIONS


Luminaire lumens (with diffuser): Warm White, Cool White, Daylight White

| 1250 lm

1300 lm

1250 lm

| 1900 lm

1970 lm

1900 lm

| 2500 lm

2530 lm

2520 lm

---|---|---|---


Lumens from chip (array): Warm White, Cool White, Daylight White

| 1410 lm

1470 lm

1400 lm

| 2100 lm

2220 lm

2150 lm

| 2820 lm

2850 lm

2840 lm


Useful lumens (array): Warm White, Cool White, Daylight White

| 1130 lm

1170 lm

1130 lm

| 1700 lm

1780 lm

1720 lm

| 2250 lm

2280 lm

2270 lm

Rated Wattage| 12W| 18W| 24W
Rated luminous flux| 1130/1170/1130 lm| 1700/1780/1720 lm| 2250/2280/2270 lm
Nominal life time of the lamp| 40,000 hrs| 40,000 hrs| 40,000 hrs
Colour temperature| 3000/4000/6000K| 3000/4000/6000K| 3000/4000/6000K
Number of switching cycles before premature lamp failure| ****

15,000

| ****

15,000

| ****

15,000

Warm-up time up to 60% of the full light output| Instant full light| Instant full light| Instant full light
Dimmable| No| No| No
Nominal beam angle| 120°| 120°| 120°
Rated power| 12W| 18W| 24W
Rated lamp lifetime| 40,000 hrs| 40,000 hrs| 40,000 hrs
Displacement factor| 0.979| 0.977| 0.972
Lumen maintenance factor at end of nominal life| ≥80| ≥80| ≥80
Starting time| Instant full light| Instant full light| Instant full light
Colour rendering| ≥80 Ra| ≥80 Ra| ≥80 Ra
Colour consistency| Within 6 step Macadam ellipse| Within 6 step Macadam ellipse| Within 6 step Macadam ellipse
Rated peak intensity| 356/360/348cd| 594/600/588cd| 754/760/744cd
Rated beam angle| 120°| 120°| 120°
Voltage / Frequency| 240V~50-60Hz| 240V~50-60Hz| 240V~50-60Hz
Lumen efficacy lm / W| 104 / 108 / 104| 105 / 109 / 105| 104 / 105 / 105
Not suitable for accent lighting

See the website for more information on replacability and recycling

Model:
KFLATDL12 / KFLATDL18 / KFLATDL24
Color Temperature Selectable Recessed Flat LED Downlights These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION AND RETAIN FOR FUTURE REFERENCE

READ THIS FIRST

  • Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
  • This light fitting must be installed by a competent person in accordance with the current building and IEE wiring regulations.
  • As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna
  • Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
  • This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic service. Using this fitting in any other environments may result in a shortened working life, for example where there is prolonged periods of use or higher than normal ambient temperatures such as lighting public or shared spaces or in nursing / care home facilities.
  • Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.
  • This unit is suitable for indoor use only.
  • This product is suitable for installation on surfaces with normal flammability e.g. wood, plasterboard and masonry. It is not suitable for use on highly flammable surfaces (e.g. polystyrene, textiles).
  • Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
  • The chosen location of your new fitting should allow for the product to be securely mounted and safely connected to the mains supply (lighting circuit).
  • Do not cover the fitting and/or transformer with any insulating materials.
  • Do not attach to surfaces which are damp, freshly painted or otherwise electrically conductive (e.g. metallic surfaces).
  • This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
  • When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
  • This product is double insultated. DO NOT CONNECT ANY PART TO EARTH.

LAMP REPLACEMENT

This luminaire has a sealed LED lamp and is maintenance free, no lamp replacement is required.

IMPORTANT:
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.

INSTALLATION

  1. Locate suitable position without obstructions (allow minimum 75mm around the hole for the spring clips) and minimum ceiling void height of 150mm. (see Fig.1 opposite).

  2. Isolate mains.

  3. Make a round fixing hole in the ceiling (see sizes below), ensuring that the hole is cut accurately, we recommend the use of a circular hole cutter.

  4. KFLATDL12: 155mm diameter.

  5. KFLATDL18: 220mm diameter.

  6. KFLATDL24: 280mm diameter.
    NOTE : Ensure cut-out holes are burr free before installations.

  7. Set colour temperature to the desired option by selecting the appropriate switch setting on the back of the fitting.

  8. 6000K – Daylight

  9. 4000K – Cool White

  10. 3000K – Warm White

  11. Make connection to driver:

  12. Live – Brown wire marked (L)

  13. Neutral – Blue wire marked (N)

  14. Before feeding the luminaire into the hole, ensure the large spring clips point up. (See Fig. 2).

  15. Feed the rest of luminaire into the hole in the ceiling ensuring it is flush to the mounting surface. (See Fig. 3).

  16. Switch on and test the luminaire.

EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:

Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007). Environment Agency Registered Producer: WEE/ GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST – DO NOT DISPOSE WITH HOUSEHOLD WASTE.

CLEANING:

Clean this fitting only with a soft dry cloth. Do not use any chemical or abrasive cleaners.

IF YOU EXPERIENCE PROBLEMS:

If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specific instructions regarding individual installations

Email: sales@eterna-lighting.co.uk
technical@eterna-lighting.co.uk
Visit o Issue 0522 ur website: www.eterna-lighting.co.uk

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Eterna User Manuals

Related Manuals