Table of Contents
ENERGY CONTROLS
NEW IMPROVED RANGE
GEFL – Our range of low-profile, easy-to-install, flush-mounted presence
detectors
GEFL
- Lux level sensing
- Presence detection switching
- Adjustable timer
- Switches any type of load
- Works with any type of lamp
Load Rating at 230VAC
R | I | F | CFL | LED | Time Delay |
---|---|---|---|---|---|
8A | 8A | 4A | 3A | 3A | 1m–30m |
R = Resistive I = Incandescent F = Fluorescent CFL = Compact Fluorescent Lamp
GEFL-PB
GEFL features, plus:
- Lux level set up via push button operation
- Timer also adjustable via push-button operation
GEFL-PB-ABS NEW
GEFL features, plus:
-
Absence or presence detection switching*
-
Lux level set up via push button operation
-
Timer also adjustable via push-button operation
-
See reverse for an explanation of presence and absence detection
GEFL-IR NEW
GEFL features, plus:
- Lux level set up via GEFL-HS handset
- The timer is also adjustable via the GEFL-HS handset
GEFL-HS NEW
Compact infrared GEFL-IR programming handset.
- Easy to set lux and time
- Program GEFL-IR from ground level
GESM
A surface-mounted presence detector with easy push button set up, that
provides auto on/auto off switching.
- IP54 Rating
- Lux level sensing
- Presence detection switching
- Knock-outs for conduit/ side entry wiring
- Adjustable timer
- Switches any type of load
- Works with any type of lamp
- Set up via easy push button operation
GESM
Load Rating at 230VAC
R | I | F | CFL | LED | Time Delay |
---|---|---|---|---|---|
10A | 10A | 6A | 3A | 3A | 10s–30m |
R= Resistive I= Incandescent F= Fluorescent CFL= Compact Fluorescent Lamp
Presence and absence explained
The choice between presence and absence detection for different spaces can make a big difference in user-friendliness and the amount of energy saved.
Presence Detection: Detectors will switch on lighting automatically when a person enters the room, and switch off lighting automatically when no movement is detected.
Absence Detection : Upon entering the room the person switches on the
light as normal, when no movement is detected the detector switches off the
lighting automatically.
Lights can also be switched off manually.
CP Electronics
A business unit of Legrand Electric Limited
Brent Crescent
London, NW10 7XR
T: +44 (0)333 900 0671
F: +44 (0)333 900 0674
www.green-i.co.uk
Contact us on
0333 900 0671 or to view our full range visit
www.green-i.co.uk