TRIPP-LITE SMART2200RM2U SmartPro Line Interactive UPS Owner’s Manual

June 9, 2024
Tripp Lite

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine
Wave UPS, 2U, Network Card Options, LCD Display, USB, DB9
MODEL NUMBER: SMART2200RM2U
Owner’s Manual

SMART2200RM2U SmartPro Line Interactive UPS

1000 Eaton Boulevard
Cleveland, OH 44122
United StatesTRIPP-LITE SMART2200RM2U SmartPro Line Interactive
UPS Highlights

  • 2.2kVA / 2200VA / 1920W line interactive 2U rack/tower UPS, Sine Wave
  • 120V output, Corrects brownouts and overvoltages from 83V to 145V
  • 0.9 Power Factor, Interactive LCD interface
  • 96% line-mode efficiency, 2 switched load banks
  • USB, RS232, EPO and slot for Network Card options
  • 120V NEMA 5-20P input, 4 NEMA 5-15R & 4 NEMA 515/20R outlets
  • To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later

Package Includes

  • SMART2200RM2U UPS system
  • USB, Serial & EPO cabling
  • 4 post rackmount installation kit
  • Instruction manual

Description

Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite’s unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and sitepower data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 96% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and slot for network management accessory card. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. PowerAlert UPS monitoring software is available via free download. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.

Features

  • Tripp Lite SMART2200RM2U line interactive 2U rack/tower UPS with 2200VA / 2.2kVA / 1920W capacity
  • Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V
  • NEMA 5-20P input plug; 4 NEMA 5-15R & 4 NEMA 5-15/20R output receptacles, Two independently switchable output load banks
  • Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
  • High 96% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
  • Internal batteries offer 12 minutes at 50% load (960W) and 4.5 minutes at 100% load (1920W)
  • Hot-swappable, user-replaceable internal batteries can be replaced with no disruption to connected equipment
  • Intelligent battery management system extends battery life
  • Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information
  • LCD interface also supports a number of advanced user setup and operating preferences
  • Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement
  • Built-in USB, RS-232 and slot for network management accessory cards; Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD and RELAYIOCARD
  • HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download from tripplite.eaton.com/products/power-alert
  • Built-in Emergency Power Off (EPO) interface with cable

Specifications

OVERVIEW

UPC Code| 37332150622
UPS Type| Line-Interactive
INPUT
Input Phase| Single-Phase
Rated input current (Maximum Load)| 16A (120V)
Nominal Input Voltage(s) Supported| 120V AC
UPS Input Connection Type| 5-20P
Input Circuit Breakers| 20A
UPS Input Cord Length (ft.)| 10
UPS Input Cord Length (m)| 3.1
Recommended Electrical Service| 20A 120V
OUTPUT
Output Capacity (VA)| 2200
Output Capacity (kVA)| 2.2
Output Capacity (Watts)| 1920
Output Capacity (kW)| 1.92
Power Factor| 0.87
Nominal Voltage Details| 120v nominal output in battery mode
Frequency Compatibility| 60 Hz
Output Voltage Regulation (Line Mode)| -14%, +6%
Output Voltage Regulation (Battery Mode)| +/- 5%
Load Management Receptacles| Two switchable single-outlet load banks
Output AC Waveform (AC Mode)| Pure Sine wave
Output AC Waveform (Battery Mode)| Pure Sine wave
Nominal Output Voltage(s)
Supported| 110V; 115V; 120V
Output Receptacles| (4) 5-15R; (4) 5-15/20R
Individually Controllable Load Banks| Yes
BATTERY
Battery Type| Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)| 4.5 min. (1920W)
Runtime Half Load (min.)| 12 min. (960W)
Expandable Runtime| No
DC System Voltage (VDC)| 48
Battery Recharge Rate (Included Batteries)| Less than 4.5 hours from 10% to 90% (typical, full load discharge)
Battery Access| Front panel battery access door
Internal UPS Replacement Battery Cartridge|  <a class=”productLink” href=”// tripplite.eaton.com / 2U-UPS- Replacement-48VDC-Battery-
Cartridge-1-set-4select-Tripp-Lite-SmartPro-UPS~RBC94-2U”>RBC94-2U 
Battery Replacement Description| Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description| Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Overvoltage Correction| Input voltages between 127 and 145  are reduced by 12%
Undervoltage Correction| Input voltages between 108 and 96 are boosted by 12%
Severe Undervoltage Correction| Input voltages between 83 and 95 are boosted by 24%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display| Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches| 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Alarm Cancel Operation| Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm| Audible alarm indicates UPS startup, power-failure, low- battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating| 570
UPS AC Suppression Response Time| Instantaneous
EMI / RFI AC Noise Suppression| Yes
PHYSICAL
Primary Form Factor| Rackmount
Rack Height| 2U
Cooling Method| Fan
Included Mounting Accessory Description| Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories| 4 post 19 inch rackmount
Installation Form Factors Supported
with Optional Accessories| 2 post rackmount ( <a class=”productLink” href=”// tripplite.eaton.com /2-Post-Rack-Mount- Wall-MountAdapter-Kit- select-Rack -Mount- UPS- Systems~2POSTRMKITWM”>2POSTRMKITWM ); 2-4 post front
rail rackmount ( <a class=”productLink”
href=”// tripplite.eaton.com /Heavy-Duty-2-post- Front-Mounting-EarKit~UPSHDEARKIT”>UPSHDEARKIT ); 4 post rackmount short-depth ( <a class=”productLink”
href=”// tripplite.eaton.com /4-Post-1U- Universal-Adjustable-Rack-Mount-Shelf-Kit-for-Wall- MountRacks~4POSTRAILKITWM”>4POSTRAILKITWM ); Tower ( <a class=”productLink”
href=”// tripplite.eaton.com /2U-9U-Tower-Stand- Kit-select-Rack-Mount-UPS-Systems~2-9USTAND”>29USTAND );  Wallmount ( <a class=”productLink” href=”// tripplite.eaton.com /2-Post-Rack-MountWall- Mount-Adapter-Kit-select-Rack-Mount-UPS- Systems~2POSTRMKITWM”>2POSTRMKITWM )
Minimum Required Rack Depth (cm)| 63.5
Minimum Required Rack Depth
(inches)| 25
Optional Mounting Accessory Notes| Optional  <a class=”productLink” href=”// tripplite.eaton.com /2U-9U-Tower-Stand- Kit-select-Rack-Mount-UPSSystems~2-9USTAND”>2-9USTAND  enables upright tower UPS placement;  <a class=”productLink”
href=”// tripplite.eaton.com /2-Post-Rack-Mount- Wall-Mount-Adapter-Kit-select-Rack-Mount- UPSSystems~2POSTRMKITWM”>2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  
<a class = “productLink” href=”// tripplite.eaton.com /4-Post-1U-Universal- Adjustable-Rack-Mount-Shelf-Kit-forWall-Mount- Racks~4POSTRAILKITWM”> 4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  <a class=”productLink
” href=”//tripplite.eaton.com/HeavyDuty-2-post- Front-Mounting-Ear-Kit~UPSHDEARKIT”>UPSHDEARKIT 
enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary UPS Depth (mm)| 494
Primary UPS Height (mm)| 87
Primary UPS Width (mm)| 440
Shipping Dimensions (hwd / in.)| 8.90 x 24.30 x 21.30
Shipping Dimensions (hwd / cm)| 22.61 x 61.72 x 54.10
Shipping Weight (lbs.)| 77.8
Shipping Weight (kg)| 35.29
UPS Housing Material| Steel
UPS Power Module Dimensions (hwd, cm)| 8.71 x 43.99 x 49.43
UPS Power Module Dimensions (hwd, in.)| 3.43 x 17.32 x 19.46
UPS Power Module Weight (kg)| 26.13
UPS Power Module Weight (lbs.)| 57.6
Unit Weight (lbs.)| 57.56
Unit Weight (kg)| 26.11
ENVIRONMENTAL
Operating Temperature Range| 32° to 104°F (0° to 40°C)
Storage Temperature Range| 5° to 122°F (-15° to 50°C)
Relative Humidity| 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)| 306
Battery Mode BTU / Hr. (Full Load)| 1157
AC Mode Efficiency Rating (100% Load)| 96%
Audible Noise| 45 dBA maximum, front side 1m
COMMUNICATIONS
Network Management Cards| SNMPWEBCARD;  <a class=”productLink” href=”//tripplite.eaton.com/Web-Management- Accessory-
CardSmartPro- SmartOnline-UPS-Systems~TLNETCARD”>TLNETCARD ;  <a class=”
productLink” href=”//tripplite.eaton.com/Web- Management-Accessory-Card~WEBCARDLX”>
WEBCARDLX ;  <a class= “productLink”
href=”//tripplite.eaton.com/Programmable- Relay-I-OCard~RELAYIOCARD”>RELAYIOCARD 
Network Monitoring Port Description| Supports detailed monitoring of UPS and site power conditions
PowerAlert Software| For local monitoring via the UPS’s built-in communication ports, download
PowerAlert software at https://tripplite.eaton.com/products/power-alert
Communications Cable| USB, DB9 and EPO cabling included
Watch Dog Compatibility| Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network UPS Tools (NUT) Compatibility| NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems
at https://networkupstools.org/stablehcl.html?manufacturer=Tripp%20Lite
Network Management Card Description| Network management card optional
Communications Interface| DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time| 5 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode)
Low Voltage Transfer to Battery Power (Setpoint)| 83
High Voltage Transfer to Battery Power (Setpoint)| 145
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure)| Cold-start operation supported
High Availability UPS Features| Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
Green Energy-Saving Features| Greater than 95% efficiency – GREEN UPS; Individually controllable load banks
Grounding Lug| Back panel grounding lug
STANDARDS & COMPLIANCE
Product Certifications| CSA (Canada); NOM (Mexico); UL 1778
Product Compliance| RoHS; FCC Part 15 Class A (USA)
WARRANTY & SUPPORT
Product Warranty Period (Worldwide)| 2-year warranty, 3 year with registration. Note: <a class=”insuranceLink”
href=”//tripplite.eaton.com /support/product- warranty-registration”>Registration is required for 3-year warranty.
Connected Equipment Insurance (U.S., Canada & Puerto Rico)| $250,000 <a class=”insuranceLink”
href=”//tripplite.eaton.com/support/insurance- policy“>Ultimate Lifetime Insurance 

© 2023 Eaton. All Rights Reserved.
Eaton is a registered trademark.
All other trademarks are the property of their respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Tripp Lite User Manuals

Related Manuals