TRIPP LITE B002-DP1AC2-N4 Secure KVM Switches NIAP Protection Profile
Version 4.0
Product Information
Secure KVM Switches, NIAP Protection Profile Version 4.0
The Secure KVM Switches are designed to provide secure access to multiple
computers from a single console. The NIAP Protection Profile Version 4.0
ensures a high level of security compliance. The product is available in
different models including DisplayPort, HDMI, DP to HDMI, and DVI.
Features
- Secure access to multiple computers from a single console
- NIAP Protection Profile Version 4.0 compliant
- Available in different models including DisplayPort, HDMI, DP to HDMI, and DVI
Package Includes
- KVM Switch
- Power supply
- User manual
Optional Accessories
Audio/video cables appropriate for the switch model.
System Requirements
All devices being connected to the KVM switch should be turned off before
proceeding with installation.
Important Safety Instructions
- Install the power supply before connecting the power cable to the power supply.
- Unplug the power cable before removing the power supply.
- If the system has multiple power sources, disconnect power from the need for service.
- The device does not operate normally when the operating power of the KVM is low.
Installation
- Using audio/video cables appropriate for your switch model, connect the KVM switch to the computers and monitor.
- Connect the power supply to the KVM switch.
- Power on all connected computers and monitor. The front-panel LEDs will begin to flash.
- To switch among the connected computers, simply push the desired input button on the front panel of the KVM.
Miscellaneous KVM Functionality
The following steps are intended for the system administrator only.
Disabling CAC Functionality
To disable CAC for any port on the KVM switch (all CAC ports are enabled as
default), use the front-panel push buttons to switch the KVM to the port whose
CAC mode you wish to change. Once selected, the push-button LED for the
selected port will illuminate blue to indicate CAC functionality is enabled.
Press and hold the button for 3 seconds until the blue push-button LED turns
off. CAC functionality for the port is now disabled.
Enabling CAC Functionality
To enable CAC for any port on the KVM switch, use the front-panel push
buttons to switch the KVM to the port whose CAC mode you wish to change. Once
selected, the push-button LED for this specific channel should be off to
indicate CAC functionality is disabled. Press and hold the button for 3
seconds until the blue push-button LED turns on. CAC functionality for the
port is now enabled.
CAC Port Configuration
- Download and run the Administration and Security Management Tool executable file from tripplite.com/support.
- The Administration and Security Management screen will appear.
- Initiate the session by pressing the following hotkey command, one key after another: [Ctrl][Ctrl][c][n][f][g]
DisplayPort Models:
B002-DP1AC2-N4, B002-DP2AC2-N4, B002-DP1AC4-N4,
B002-DP2AC4-N4, B002-DP1AC8-N4
HDMI Models:
B002-H1AC2-N4, B002-H2AC2-N4, B002-H1AC4-N4, B002-H2AC4-N4
DP to HDMI Models:
B002-HD1AC2-N4, B002-HD2AC2-N4, B002-HD1AC4-N4,
B002-HD2AC4-N4
DVI:
B002-DV1AC2-N4, B002-DV2AC2-N4, B002-DV1AC4-N4,
B002-DV2AC4-N4, B002-DV1AC8-N4
WARRANTY REGISTRATION
Register your product today and be automatically entered to win an ISOBAR®
surge protector in our monthly drawing!
tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA •
tripplite.com/support
Copyright © 2023 Tripp Lite. All rights reserved.
Package Includes
- B002-Series Secure KVM Switch
- 12V 3A External Power Supply*
- Owner’s Manual
*Includes NEMA 1-15P (North America), CEE 7/16 Schuko (Europe), BS 1363 (UK) and AS/NZS 3112 (Australia) plugs.
Optional Accessories
- P312-Series 3.5 mm Stereo Audio Cables
- P569-XXX-CERT Premium High-Speed HDMI Cables
- P782-XXX-HA HDMI/USB KVM Cable Kit
- P782-XXX-DH HDMI/DVI/USB KVM Cable Kit
- P783-Series DisplayPort KVM Cable Kit
- P580-Series DisplayPort Cables
- U022-Series USB 2.0 A/B Device Cables
*XXX refers to length (e.g. 006 = 6 ft., 010 = 10 ft., and so on)
System Requirements
-
DisplayPort, DVI or HDMI monitor
Note: The number of displays needed can be determined from the model name. The number directly preceding the “A” in the model name indicates how many monitors can be connected to the KVM switch. -
Wired USB mouse and keyboard without internal hub or composite device functions*
-
Computer with a DisplayPort, DVI or HDMI port
-
Computer with an available USB port (USB 2.0 required for Common
Access Card [CAC] support) -
Computer with an available 3.5 mm stereo audio port
-
Speakers with a 3.5 mm stereo audio port
-
Authorized User authentication devices: USB devices identified as user authentication (base class 0Bh, e.g. Smart-card reader, PIV/CAC reader, Token, or Biometric reader)
-
Compatible with all major operating systems
*Wireless keyboard and mouse are not supported
Features
- Certified to NIAP / Common Criteria Protection Profile for Peripheral Sharing Switches, Version 4.0.
- Safely switch between computers (up to 8) with varying security levels.
- Select models support connection of Common Access Cards (CAC), biometric readers and other smart card readers.
- DisplayPort models support video resolutions up to 3840 x 2160 @ 30 Hz. HDMI models support resolutions up to 3840 x 2160 @ 60 Hz.
- Anti-Tampering Protection – Internal Anti-Tamper switches disable the KVM if the housing is opened, causing it to become inoperable. When disabled, the front-panel LEDs will flash repeatedly and theinternal buzzer will sound repeatedly. This is also caused by the exhaustion of the internal battery, which has a life rating of over 10 years. Opening the housing will disable the unit and void the warranty
- Tamper-Evident Seals – The enclosure of the unit is protected with tamper-evident seals to provide visual evidence if the unit has been tampered with or compromised. Removing these labels will void the warranty.
- Protected Firmware – The unit features special protection that prevents reprogramming or reading firmware, protecting against attempts to alter the logic of the KVM.
- High Isolation on USB Channels – Opto-isolators are used to keep USB data paths electrically isolated from each other, preventing data leakage between ports.
- Secure EDID Emulation – Secure EDID learning and emulation prevents unwanted and unsecure data from being transmitted through the DDC line.
- Automatic Keyboard Buffer Clearing – The keyboard buffer is automatically cleared after data transmission, so no information is left stored in the switch.
- No Memory Buffer – The only way to access connected computers is via push button. Port switching methods such as On-Screen Display (OSD) and Hotkey Commands have been excluded to further ensure data integrity.
Important Safety Instructions
- Read all instructions and save them for future reference.
- Follow all warnings and instructions marked on the device.
- Do not place the device on any unstable surface (cart, stand, table, etc.). If the device falls, serious damage will result.
- Do not use the device near water.
- Do not place the device near, or over, radiators or heat registers. The device cabinet contains slots and openings to allow for adequate ventilation. To ensure reliable operation and to protect against overheating, these openings must never be blocked or covered.
- The device should never be placed on a soft surface (bed, sofa, rug, etc.) as this will block its ventilation openings. Likewise, the device should not be placed in a built-in enclosure unless adequate ventilation has been provided.
- Never spill liquid of any kind on the device.
- Unplug the device from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.
- The device should be operated from the power source type as indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power utility.
- Do not allow anything to rest on the power cord or cables. Route the power cord and cables so that they cannot be stepped on or tripped over.
- If an extension cord is used with this device, make sure the total ampere rating of all products used on the cord does not exceed the extension cord ampere rating. Make sure the total rating of all products plugged into the wall outlet does not exceed 15 amperes.
- Position system cables and power cables carefully. Make sure nothing rests on any cables.
- To help protect your system from sudden transient increases and decreases in electrical power, it is recommended you plug your devices into a Tripp Lite Surge Protector, Line Conditioner or Uninterruptible Power Supply (UPS).
- When connecting or disconnecting power to hot-pluggable power supplies, observe the following guidelines:
- Install the power supply before connecting the power cable to the power supply
- Unplug the power cable before removing the power supply.
- If the system has multiple power sources, disconnect power from the system by unplugging all power cables from the power supplies.
- Never push objects of any kind into or through cabinet slots. They may touch dangerous voltage points or short out parts, resulting in a risk of electrical shock or fire.
- If the following conditions occur, unplug the device from the wall outlet and bring it to qualified service personnel for repair.
- The power cord or plug has become damaged or frayed.
- Liquid has been spilled into the device.
- The device has been exposed to rain or water.
- The device has been dropped or the cabinet has been damaged.
- The device exhibits a distinct change in performance, indicating a need for service.
- The device does not operate normally when the operating instructions are followed.
- Only adjust those controls that are covered in the operating instructions. Improper adjustment of other controls may result in damage that will require extensive work by a qualified technician to repair.
- This device is designed for IT power distribution systems with up to 230V phase-to-phase voltage.
- To prevent damage to your installation, it is important that all devices are properly grounded.
- This device is equipped with a three-wire grounding-type plug. This is a safety feature. If you are unable to insert the plug into the outlet, contact an electrician to replace your outlet with one that will accept this type of plug. Do not attempt to defeat the purpose of the grounding-type plug. Always follow your local/national wiring codes.
- Warning! There is a risk of explosion if the battery is replaced with an incorrect battery type. Do not attempt to service the device yourself. Refer all servicing to qualified service personnel.
Installation
Note: Before proceeding with installation, make sure all devices being connected to the KVM switch are turned off.
-
Using audio/video cables appropriate for your switch model, connect the video output port of each computer you are adding to the video input ports of the KVM Switch.
Note: Models with Dual Monitor capability require two available video ports per computer. -
Using USB A/B device cables, connect a USB port on each computer being added to the USB input port of the KVM Switch. Additional USB A/B cables are needed for the CAC (Common Access Card) connections as there are separate USB ports on the KVM Switch for CAC and K/M connections.
-
Using 3.5 mm stereo audio cables, connect the audio output of each computer you are adding to the audio input ports of the KVM Switch.
-
Using the appropriate audio/video cable, connect a monitor appropriate for your switch model to the console video output port of the KVM switch.
-
Connect a wired USB keyboard and mouse to the console USB keyboard and mouse ports of the KVM Switch.
Note: Keyboards and mice with internal USB hub or composite device functions are not supported. Wireless keyboards and mice are not supported. -
Connect a set of speakers to the console audio output port of the KVM Switch using a 3.5 mm stereo audio cable.
Note: Microphones or headsets with microphones are not supported. -
Connect a CAC reader to the console CAC port of the KVM Switch.
Note: CAC readers with external power sources are not supported. The KVM will terminate an open session upon the removal of the connected CAC reader or Authentication device. -
Power on the KVM by connecting the included external power supply and plugging it into a Tripp Lite Surge Protector, Power Distribution Unit (PDU) or Uninterruptible Power Supply (UPS).
-
Power on all connected computers and monitor. The front-panel LEDs will begin to flash.
Note: The computer connected to port 1 will always be selected by default after power-up. -
To switch among the connected computers, simply push the desired input button on the front panel of the KVM. If an input port is selected, the LED of that port will turn on.
Note: The KVM will terminate an open session upon switching to a different computer.
KVM LEDs
Port-Selection LEDs
- When the LED is off, the corresponding port is not currently selected.
- When the LED is on, the corresponding port is currently selected.
- When the LED is flashing, the EDID Learn process is occurring.
Push-Button LEDs
- When the push-button LED of a non-selected port is off, the corresponding port is not currently selected.
- When the push-button LED of the selected port is off, CAC functionality has been disabled for the corresponding port.
- When the push-button LED is on, the corresponding port is currently selected and CAC functionality is enabled.
- When the push-button LED is flashing, the EDID Learn process is occurring.
Port-Selection and Push-Button LEDs
- When all Port-Selection and Push-Button LEDs are flashing simultaneously, the USB peripheral connected to the console keyboard or mouse port has been rejected.
Console Video Port LED
- When the LED is off, a monitor is not connected.
- When the LED is illuminated, a monitor is connected.
- When the LED is flashing, there is a problem with EDID. Reseat the power of the KVM to resolve these issues.
Console CAC Port LED
- When the LED is off, a CAC device is not connected.
- When the LED is on, an authorized and functional CAC device is connected.
- When the LED is flashing, a non-CAC peripheral is connected.
Miscellaneous KVM Functionality
Note: The following steps are intended for the system administrator only
Disabling CAC Functionality
To disable CAC for any port on the KVM switch (all CAC ports are enabled as
default), use the front-panel push buttons to switch the KVM to the port whose
CAC mode you wish to change. Once selected, the push-button LED for the
selected port will illuminate blue to indicate CAC functionality is enabled.
Press and hold the button for 3 seconds until the blue push-button LED turns
off. CAC functionality for the port is now disabled.
Enabling CAC Functionality
To enable CAC for any port on the KVM switch, use the front-panel push buttons
to switch the KVM to the port whose CAC mode you wish to change. Once
selected, the push-button LED for this specific channel should be off to
indicate CAC functionality is disabled. Press and hold the button for 3
seconds until the blue push-button LED turns on. CAC functionality for the
port is now enabled.
CAC Port Configuration
Note : The following steps are intended for the system administrator. CAC
port configuration is an optional feature, allowing registration of any USB
peripheral to operate with the KVM. Only one peripheral can be registered at a
time, and only the registered peripheral will be able to operate with the KVM.
If a peripheral other than the registered peripheral is plugged in to the
USB-A CAC port, it will not work. When no peripheral is registered, the KVM
will default to operate with any CAC Reader. To configure the USB-A CAC port,
follow the instructions below.
Note: Only one computer connected to port 1 is required for this
operation.
-
From the connected computer, download the Administration and Security Management Tool from tripplite.com/support.
-
Once downloaded, run the Administration and Security Management
Tool executable file. The Administration and Security Management screen will appear. -
. Initiate the session by pressing the following hotkey command, one key after another.
[Ctrl][Ctrl][c][n][f][g] -
Upon completing the command, the mouse connected to the KVM will stop functioning. A prompt will appear to enter the Credential ID.
-
Log in by entering the default username “admin” and pressing Enter.
-
Enter the default password “12345” and press Enter.
-
Select option 2 from the menu on your screen and press Enter.
-
Connect the USB peripheral device to be registered to the console
USB-A CAC port on the KVM. Wait until the KVM is reading the new peripheral information. -
When registration is completed, the KVM will list the information of the newly configured peripheral on the screen and vibrate 3 times.
Note: The open session will be immediately terminated upon the removal of the registered CAC device.
AUDITING: Dumping the Event Log
Note: The following steps are intended for the system administrator.
The Event Log is a detailed report of critical activities stored in the KVM or
KVM memory. To view or dump the Event Log, follow the instructions below.
Note: Only one computer connected to port 1 is required for this
operation.
-
Open the Administration and Security Management Program (see the EDID Learn section for download instructions). The Administration and Security Management screen will appear.
-
Initiate the session by pressing the following hotkey command. Hit each key one after another.
[Ctrl][Ctrl][c][n][f][g] -
Upon completing the command, the mouse connected to the KVM will stop functioning. A prompt will appear to enter the Credential ID.
-
Log in by entering the default username “admin” and pressing Enter.
-
Enter the default password “12345” and press Enter.
-
Request a Log Dump by selecting option 5 in the menu.
RESET: Restore Factory Defaults
Note : The following steps are intended for the system administrator.
Restore Factory Defaults will reset all settings on the KVM to their original
state:
- CAC port registration will be removed
- KVM settings will be reset to factory defaults
To restore Factory Defaults, follow the steps below.
Note: Only one computer connected to port 1 is required for this
operation.
-
Open the Administration and Security Management Program (see the CAC Port Configuration section for download instructions). The Administration and Security Management screen will appear.
-
Initiate the session by pressing the following hotkey command, one key after another.
[Ctrl][Ctrl][c][n][f][g] -
Upon completing the command, the mouse connected to the KVM will stop functioning. A prompt will appear to enter the Credential ID.
-
Log in by entering the default username “admin” and pressing Enter.
-
Enter the default password “12345” and press Enter.
-
Select “Restore Factory Default” option from the menu and press Enter.
Note: A comprehensive feature list and instructions for the Administration and Security Management Utility can be found in the Administrator’s Guide available at tripplite.com/support.
Power Up Self-Test
If all front-panel LEDs are on and not flashing, the Power Up Self-Test failed
and all functions are disabled. Check if any of the front-panel power
selection buttons are jammed. In this case, release the jammed button and
recycle power. If Power Up Self-Test continues to fail, contact Tripp Lite
Technical Support at tripplite.com/support.
Front Panel Control
To switch to an input port, simply push the desired input button on the front
panel of the KVM. If an input port is selected, the LED of that port will turn
on. An open session is terminated upon switching to a different computer.
Warranty and Product Registration
3-Year Limited Warranty
TRIPP LITE warrants its products to be free from defects in materials and
workmanship for a period of three (3) years from the date of initial purchase.
TRIPP LITE’s obligation under this warranty is limited to repairing or
replacing (at its sole option) any such defective products. To obtain service
under this warranty, you must obtain a Returned Material Authorization (RMA)
number from TRIPP LITE or an authorized TRIPP LITE service center. Products
must be returned to TRIPP LITE or an authorized TRIPP LITE service center with
transportation charges prepaid and must be accompanied by a brief description
of the problem encountered and proof of date and place of purchase. This
warranty does not apply to equipment which has been damaged by accident,
negligence or misapplication or has been altered or modified in any way.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Some states do not permit limitation or exclusion of implied warranties;
therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the
purchaser.
PRODUCT REGISTRATION
Visit tripplite.com/warranty today to
register your new Tripp Lite product. You’ll be automatically entered into a
drawing for a chance to win a FREE Tripp Lite product!*
- No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>