YCOEV RC06 Remote Dog Training Collar User Guide
- June 10, 2024
- YCOEV
Table of Contents
- YCOEV RC06 Remote Dog Training Collar
- Packing List
- Technical Parameter
- Features
- Important statement
- Receiver Introduction
- Transmitter Introduction
- Using Instructions
- Setting Guide
- Function Testing
- Wear the Bark Collar
- FAQ
- Troubleshooting
- Terms of Use & Liability
- FCC STATEMENT
- Manufacturer
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
YCOEV RC06 Remote Dog Training Collar
Our product is designed to cultivate pets good habits not to punish them. Please do not overuse this product on pets.
NOTE: Please read the user guide before using this product and keep the user guide properly.
Packing List
Technical Parameter
RCO6 Bark collar(Receiver)
RCO6 Remote control(Transmitter)
Features
- Remote control(Transmitter) dot matrix colour screen display
- Three training modes: warning sound, vibration and E-shock
- Remote control(Transmitter) can be paired with 3 receivers
- 18 levels of intelligent graded electric shock, 8 levels of vibration
- Bark collar(Receiver) with RGB dog finder light design, two kinds of dog finder indication
- Two-way wireless communication, Remote control(Transmitter) can display receiver power
- Remote control transmitter can shut down the receiver remotely
- Adopting magnetic charging, the receiver is IP67 dustproof and waterproof, and the transmitter is not waterproof
Important statement
Safe use statement
- It is forbidden to use this product for aggressive dogs. Aggressive dogs can cause serious injury or even death to others. If you are not sure whether the product is suitable for your dog, please consult a professional dog training instructor.
- It is forbidden for children to play with this product, please place the product out of reach of children.
Electric shock safety statement
- Before using the bark collar, please make sure your dog is healthy. If you are not sure about this, please consult the veterinarian.
- When the bark collar in the power-on state, the human body should avoid touching the electric shock contactors of the product.
- If you find rashes and sores on the wearing part of your pet, please stop using this product until pet’ s skin returns to health.
Wearing and training safety statement
-
Your pet needs a firm leash to prevent violent reactions during training, so you can hold the leash to prevent your pet from running around. The safety of you and your pet is very important.
-
Pets should not wear the bark collar for more than 12 hours a day, and please adjust the wearing position every 1-2 hours.
-
Bark collar is suitable for dogs who weigh more than 3.6 kg and are older than 6 months.
-
It is forbidden to use bark collar as a matching collar for a pet leash.
-
It is very important to check the shock vibration contact area on the pet s neck every day for rashes and sores.
-
We recommend that you cut the long hair around the dog’s throat appropriately, but it is not recommended to shave the hair completely.
-
Before playing with your pet, please remove the collar to avoid false triggering.
-
The IP67 standard indicates that the device can be left in water up to one metre deep for half an hour without water entering the interior of the product and is also dustproof.
Note: The IP67 standard is the resut of static laboratory tests.
Receiver Introduction
Transmitter Introduction
Using Instructions
Charge the product before using it
- When the remote control(Transmitter) is charging, the battery icon is flashing and the charging time is 1.5-2 hours. The battery icon remains on when the battery is fully charged.
- When the Bark Collar(Receiver) is charging, the status light is red and the charging time is 1.5-2 hours. When the battery is fully charged, the status light is on in green.
Turn On/off
- Press and hold the transmitter’s ( ) button for 2 seconds, the screen will light up to indicate that it is powered on. In the power-on state, press and hold the button for 2 seconds to power off.
- Press and hold the receiver’s button for 2 seconds, the receiver will “beeping…beeping twice means power on. In the power-on state, the green statue light flashes once every 5 seconds (The status light will turn off within 10 minutes of each operation). Press and hold the button for 2 seconds, and the receiver will make a long “beeping… ” to indicate that poewr off.
Remote Power-off
When both the transmitter and receiver are turned on, press and hold the button and the CH button of the transmitter for 2s to turn off the transmitter and receiver, during which the receiver icon on the transmitter screen flashes.
Turn on/off Channel
- The factory default of a single receiver is channel 1, and channel switch- ing is disabled. If the user needs channel switching, please enable the channel switching function first.
- In the standby state, press and hold the CH button of the transmitter for 5 seconds to turn on or off the channel switching function.
- When the channel switching function is turned on, the channel icon gradually lights up; when the channel switching function is turned off, the channel icon gradually turns off.
Channel setting
- When the channel switching function is enabled, short press the CH button of the transmitter to switch between channel 1, channel 2, and channel 3; when the receiver receives the command of the transmitter to switch channels, the cyan indicator light flashes 5 times.
- When the channel switching function is turned off, short press the CH button of the transmitter to switch between the paired channels; when the receiver receives the command of the transmitter to switch channels, the cyan indicator light flashes 5 times.
Key Lock Function
Push the key lock button downward to turn on the key lock function, and the key lock icon will light up. At this time, when any key is pressed, the transmitter has no functional response, and the key lock icon flashes. Push the key lock button upward to turn off the key lock function.
E-shock Level Setting
- When the screen is on, short press the +button or-button to adjust the shock level. The shock level is adjustable from 0-18, 0 is off.
Vibration level setting
- When the screen is on, short press the transmitter button to enter the vibration level setting interface.
- Short press the +key or the- key to adjust the vibration level.
- Vibration is adjustable from 1-8 levels.
- After the vibration icon flashes for 5 seconds, it will automatically exit the vibration level setting.
Dog Finder
- In the standby state, short press the transmitter button to turn on the receiver’s dog finder function.The white light flashes quickly after the first press, the transmitter’s dog finder icon flashes, and automatically turns off after 10 minutes.
- Short press the button again to switch the display of the breathing light, and the transmitter’s dog finder icon remains on.
- Short press the button for the third time to turn off the receiver’s dog finder function.
Training Instruction
- In the standby state, short press the button of the transmitter, the receiver will beep for 1 second after receiving the command; long press the button, the receiver will stop working after beeping for 10 consecutive times.
- In the standby state, short press the i0 button, the receiver vibrates for 1 second after receiving the command; long press the button, the receiver will stops working after vibrating continuously for 10 times.
- In the standby state, short press the button, and the receiver receives the command to shock once at the preset level; long press the button, the receiver will stops working after E-shock continuously for 5 times.
Pairing Instruction
- When the receiver is powered on, short-press the button twice to enter the pairing state, and the blue indicator light flashes.
- Switch the transmitter to the channel you want to pair, each channel can only be paired with 1 receiver, press the transmitter’s and button simultaneously for 2 seconds, the transmitter sends a pairing command to the receiver, and the channel number of the transmitter flashes.
- After the pairing is successful, the blue indicator light of the receiver will light up for 3 seconds.
- In the pairing state, if the pairing is not successful for more than 30 seconds, the receiver will automatically exit the pairing state.
Transmitter Factory Reset
- Within 15 seconds of restarting, press and hold the button and the button for 2 seconds, the backlight flashes 5 times, indicating that the factory reset is successful.
Low Battery
- When the battery of the receiver is lower than 1 bar, the red status light flashes once every 5 seconds, the receiver will automatically shut down after 20 minutes.
- When the battery of the transmitter is lower than 1 bar, the battery icon flashes, the transmitter will automatically shut down after 20 minutes.
Setting Guide
Choose the appropriate level according to the dog’s temper and Set the appropriate level according to the dog’s temper and the degree of endurance to electric shocks. Please start training from the lowest level. For example, the dog responds to the level of electric shock with ear shaking, tongue licking, neck tightening, etc. This is the appropriate level. The level of electric shock varies according to the training conditions. If the dog’s attention is highly distracted, a strong level is needed to stimulate it.
Assemble the receiver
Install the E-shock contactors
- Select the appropriate long/short E-shock contactors, and use the mounting plate to install them on the holes on the back of the product.
Install the silicone protective sleeve
- Then choose the long/short conductive silicone protective sleeve to directly cover the E-shock contact, which can effectively reduce the physical damage of the E-shock contact to the dog’s skin.
Function Testing
After assembly, functional testing is recommended. Please follow the steps below to test.
- Short press the button of the transmitter to test the sound, the receiver will beep for 1 second.
- Short press the button of the transmitter to conduct a vibration test, the receiver will vibrate for 1 second according to different vibration levels.
- Press the test board on the E-shock column of the receiver, short press the button of the transmitter to perform the E-shock test, and the light on the test board will be lit. The higher the shock level, the brighter the light.
Wear the Bark Collar
The collar ranges from 20 cm to 62 cm (8 inches to 25 inches). Before wearing, please adjust the buckles and sliders to make the collar size to the correct length to ensure the shock contacts can be firmly attached to the dog On the neck, if you can fit a finger between the collar strap and the dog’s neck, it’s the right size.
FAQ
Why doesn’t the receiver work when the transmitter is operating in E-shock function?
There may be three reasons for this problem. The first is that the transmitter and receiver are not paired, so try pairing again. Second, the E-shock contacts do not touch the skin, so try again to adjust the tightness of the collar to ensure good skin contact. Third, the level setting is not high enough, so try turning up the level of the E-shock function.
Is the product safe and humane?
All means of receiving do not cause any direct damage to the pet’s body, but can make them very uncomfortable. Even so, do not over-use this product on pets. See all safety notices in the manual.
Why don’t the receiver and transmitter work?
There may be two reasons for this problem. The first is that the transmitter and receiver are not powered on, please refer to the manual for the power-on operation. Secondly, the transmitter and receiver batteries are exhausted, please charge the receiver and transmitter, the charging time is about 2 hours.
Troubleshooting
Terms of Use & Liability
Terms of Use
- When you start using the product, it means that you have accepted all the terms, conditions and statements in this user guide.
Use it correctly
- This product is designed for pets that need training. Please use this product correctly and include reading the user guide and any specific “safety” and “caution” statements.
illegal use is forbidden
- This product is suitable for pets. This device is not designed to harm pets. Using this product not in accordance with the user guide may violate local laws.
Scope of Responsibility
The manufacturer is not responsible for any direct, indirect, punitive, non- significant losses and other indirect losses caused by incorrect use or abuse of this product. The buyer assumes all risks and responsibilities of using this product.
Modification of terms and conditions
- The manufacturer reserves the right to change the terms, conditions and declarations related to the products.
FCC STATEMENT
This product meets the requirements of China’s “Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products”.
According to the requirements of Dianguo electronic products’ restricted use of hazardous substances and relevant regulations, this product meets the 10-year environmental protection use period of the whole machine. The use period of the label refers to the use period under normal use conditions and normal humidity and temperature and does not include consumables in accordance with the requirements of the manual. Please observe the regulations for the handling of electronic and electrical equipment in the respective country. If this device is no longer required, it must not be disposed of with normal municipal waste. Sepa- rate collection of used batteries is required in many areas; please check the regulations in your area before discarding used batteries. See local regulations for more recycling information.
This device complies with Part 15 of the US FCC Rules. It also complies with the provisions of CE (2014/30/EU) and RoHS (2011/65/EU) parts.
15.19 Labelling requirements
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation
15.21 Information to user
- Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
15.105 Information to the user
_ Note: _This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential nstallatıon. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause hamful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receive
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet the general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
Manufacturer
- Quanzhou Zihe Electronics Co, Ltd.
- Address: No. 41, Wanrong Street, Luojiang District, Quanzhou City, Fujian Province, China
- Version: RCO6 (V1.0) 202207
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>