Wi-Tek WI-PS302GF-I Industrial Hardened PoE Switch Installation Guide
- June 10, 2024
- Wi-Tek
Table of Contents
- Wi-Tek WI-PS302GF-I Industrial Hardened PoE Switch
- Product Information
- Product Usage Instructions
- Package Content
- Interface and LED Indicator
- WI-PS302GF-I
- WI-PS306GF-I
- WI-PS310GF-I
- WI-PMS305GF-I
- WI-PMS306GF-I
- WI-PMS312GF-I
- WI-PS305G-I-DC
- WI-PMS310GF- Alien-I
- WI-PS206-I
- WI-PS208-I
- DIN-rail Installation
- DC Power Cable Connection
- Login WEB UI
- Warranty Card
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Wi-Tek WI-PS302GF-I Industrial Hardened PoE Switch
Product Information
The Industrial/Hardened PoE Switch by Wireless-Tek is a high-quality switch that comes in several models, including WI-PS302GF-I, WI-PS306GF-I, WI- PS310GF-I, WI-PMS305GF-I, WI-PMS306GF-I, WI-PMS312GF-I, WI-PS305G-I-DC, WI- PMS310GF-Alien-I, WI-PS206-I, and WI-PS208-I. The switch is easy to install and comes with an installation guide. It features a grounding interface, LED indicators, DIP switch, V1/V2 DC power input interface, V3 DC power input interface, and PoE ports.
WI-PS302GF-I model has one Ethernet port and one fiber port. It also has a DIP switch that can be used to enable Fiber Watchdog, PoE Watchdog, Extend Mode, and 60W PoE Mode. The LED indicators show Power indicator, Input power indicator, Link Indicator, EX Indicator, SFP Indicator, and Power Supply. The switch requires an input power of DC 37~57V and can supply 60W PoE+ via RJ-45. The PoE watchdog function can detect and reboot offline compliant PoE-powered devices. WI-PS306GF-I model has four 10/100/1000 Base-T PoE RJ-45 ports and two 1000 Base-X SFP ports. Ports 1-2 support 24V Passive/48V 802.3 af/at PoE, while Ports 3-4 support 802.3 af/at/bt 60W. The switch features a DIP switch that can be used to enable FWD, PWD, Extend, and VLAN modes. The LED indicators show Power indicator, Input power indicator, Link Indicator, PoE Indicator, and SFP Indicator. The switch requires an input power of DC 37~57V and can supply a maximum power of 120W PoE. WI-PS310GF-I model has eight 10/100/1000Base-T PoE RJ-45 ports and two 1000Base-X SFP ports. The switch features a DIP switch that can be used to enable VLAN and Extend modes. The LED indicators show Power indicator, Input power indicator, Link Indicator, and PoE Indicator. The switch requires an input power of DC 37~57V and can supply a maximum power of 240W PoE.
Product Usage Instructions
To use the Industrial/Hardened PoE Switch:
- Choose the appropriate model based on your requirements.
- Refer to the installation guide provided in the package to install the switch.
- Connect the switch to a power source using the V1/V2/V3 DC power input interface.
- Connect the Ethernet devices to the switch using the Ethernet ports.
- For models with fiber ports, connect the fiber devices to the switch using the SFP ports.
- Use the DIP switch to enable various modes such as Fiber Watchdog, PoE Watchdog, Extend Mode, VLAN, FWD, PWD, etc. based on your requirements.
- The LED indicators show the status of the switch and connected devices, such as Power indicator, Input power indicator, Link Indicator, PoE Indicator, SFP Indicator, and Power Supply.
Package Content
Interface and LED Indicator
WI-PS302GF-I
Interfaces
- Ethernet Port 1*10/100/1000 Base-T 60W PoE+ + RJ-45
- Fiber Port 1*1000 Base-X SFP slot
DIP Switch Mode
- Fiber Watchdog Monitor the fiber connection status, and if no data is transmitted, the port will restart automatically.
- PoE Watchdog All PoE ports enable PoE watchdog function, which can detect and reboot the offline compliant PoE-powered devices.
- Extend Mode The transmission distance of PoE port can be up to 250m, but the rate is limited to 10Mbps.
- 60W PoE Mode Enable this function, the PoE port will output 60W PoE power. Disable this function, the PoE port output 802.3at 30W PoE power.
LED Indicators
PW (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
V1/V2/V3 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2/V3 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
EX Indicator
- Off: Extend mode is disabled.
- On: Extend mode is enabled.
SFP Indicator
- Off: ports link down
- Green On: ports link up
- Blinking: data on TX/RX
Power Supply
Input Power
- V1 (Main): DC 37~57V, 1.8A Max
- V2 (Backup): DC 37~57V, 1.8A Max
- V3 (DC Jack): DC 37~57V, 1.8A Max
WI-PS306GF-I
Interfaces
Ethernet Port
- 4*10/100/1000 Base-T PoE RJ-45 port
- Ports 1-2 : 24V Passive / 48V 802.3 af/at PoE
- Ports 3-4: 802.3 af/at/bt 60W
- Fiber Port 2*1000 Base-X SFP
DIP Switch Mode
- FWD Monitors the fiber connection status, and if no data is transmitted, the port will restart automatically.
- PWD All PoE ports enable the PoE watchdog function, which can detect and reboot the offline compliant PoE-powered devices.
- Extend The transmission distance of the PoE port can be up to 250m, but the rate is limited to 10Mbps.
- VLAN All downlink ports are isolated from each other, but can communicate with uplink ports.
LED Indicators
PWR (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
P1/P2 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
5/6 (SFP Indicator)
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
- PoE Max On: PoE power full load
Power Supply
Input Power
- V1 (Main): DC 37~57V, 5.2A Max
- V2 (Backup): DC 37~57V, 5.2A Max
WI-PS310GF-I
Interfaces
PoE Port
- 8*10/100/1000 Base-T PoE RJ-45 port
- Ports 1-2: 24V Passive / 48V 802.3 af/at PoE
- Ports 3-4: 802.3 af/at/bt 60W
- Ports 5-8: 802.3 af/at PoE
- Uplink Port 2*1000 Combo Base-X SFP
DIP Switch Mode
- 24/48 PoE output voltage adjustment DIP switch for port 1.
- 24/48 PoE output voltage adjustment DIP switch for port 2.
- Watchdog All PoE ports enable PoE watchdog function, which can detect and reboot the offline compliant PoE-powered devices.
- Extend The transmission distance of PoE port can be up to 250m, but the rate is limited to 10Mbps.
- VLAN The transmission distance of PoE port can be up to 250m, but the rate is limited to 10Mbps.
LED Indicators
PWR (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
P1/P2 (Input power indicator)
- Off: No power supply
- On: Power is supplied via V1/V2 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
9/10 (SFP Indicator)
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
- PoE Max On: PoE power full load
Power Supply
Input Power
- V1 (Main): DC 37~57V, 8.5A Max
- V2 (Backup): DC 37~57V, 8.5A Max
WI-PMS305GF-I
Interfaces
PoE Port
- 4*10/100/1000 Base-T PoE RJ-45
- Ports 1-2: 24V Passive or 48V 802.3 af/at PoE 30W
- Ports 3-4: 802.3 af/at/bt PoE 60W
- Port 5: 802.3af/at/bt 60W PoE Input
Uplink Port
- 1*1000 Base-X SFP
- 1*10/100/1000 Base-T PoE
- Console 1*RJ-45 to RS-232 console port (115200,8,N,1)
- AL+, AL- Alarm output
- IN Alarm input
- TMS Temperature sensor interface
Buttons
- Ring Set By pressing the button over 5s, the switch will enable the fast ring mode.
- RET (Reset) By pressing the button over 5s, the switch will be restored to the original factory default setting.
LED Indicators
PWR (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
V1/V2 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
6(SFP Indicator)
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
Ring
- Off: The fast ring mode is disable.
- On: The fast ring mode is enable.
PD
- Off:The switch is powered by DC input.
- On: The switch is powered by PoE input.
Power Supply
Input Power
- V1 (Main): DC 37~57V, 5.2A Max
- V2 (Backup): DC 37~57V, 5.2A Max
WI-PMS306GF-I
Interfaces
PoE Port
- 4*10/100/1000 Base-T PoE RJ-45
- Ports 1-2 : 24V Passive or 48V 802.3 af/at PoE
- Ports 3-4: 802.3 af/at/bt 60W
- Uplink Port 2*1000 Base-X SFP
- Console 1*RJ-45 to RS-232 console port (115200,8,N,1)
- AL+, AL- Alarm output
- IN Alarm input
- TMS Temperature sensor interface
Buttons
- Ring Set By pressing the button over 5s, the switch will enable the fast ring mode.
- RET (Reset) By pressing the button over 5s, the switch will be restored to the original factory default setting.
LED Indicators
PWR (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
V1/V2 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
5, 6(SFP Indicator)
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
Power Supply
Input Power
- V1 (Main): DC 37~57V, 5.2A Max
- V2 (Backup): DC 37~57V, 5.2A Max
WI-PMS312GF-I
Interfaces
PoE Port
- 8*10/100/1000 Base-T PoE RJ-45
- Ports 1-2 : 24V Passive or 48V 802.3 af/at PoE
- Ports 3-4: 802.3 af/at/bt 60W
- Ports 5-8: 802.3 af/at PoE
- Uplink Port 4*1000 Base-X SFP
- Console 1*RJ-45 to RS-232 console port (115200,8,N,1)
- AL+, AL- Alarm output
- IN Alarm input
- TMS Temperature sensor interface
Buttons
- Ring Set By pressing the button over 5s, the switch will enable the fast ring mode.
- RET (Reset) By pressing the button over 5s, the switch will be restored to the original factory default setting.
LED Indicators
PWR (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
V1/V2 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
9, 10, 11, 12 (SFP Indicator)
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
Ring
- Off: The fast ring mode is disable.
- On: The fast ring mode is enable.
Power Supply
Input Power
- V1 (Main): DC 37~57V, 8.5A Max
- V2 (Backup): DC 37~57V, 8.5A Max
WI-PS305G-I-DC
Interfaces
PoE Port
- 4*10/100/1000 Base-T PoE RJ-45 port Ports 1-4: 802.3 af/at PoE
- Uplink Port 1*10/100/1000 Base-T RJ-45 port
DIP Switch Mode
- PoE Watchdog, all PoE ports enable PoE watchdog function, which can detect and reboot the offline compliant PoE-powered devices.
- Port VLAN All downlink ports are isolated from each other, but can communicate with uplink ports.
- EX_1-2 The transmission distance of port 1-2 can be up to 250m, but the rate is limited to 10Mbps.
- EX_1-4 The transmission distance of port 1-4 can be up to 250m, but the rate is limited to 10Mbps.
LED Indicators
PWR (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
P1/P2 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
Power Supply
Input Power
- V1 (Main): DC 37~57V, 3.5A Max
- V2 (Backup): DC 37~57V, 3.5A Max
- V3 (DC Jack): DC 37~57V,3.5A Max
- Boost Power: DC 9~52V,10A
WI-PMS310GF- Alien-I
Interfaces
PoE Port
- 8*10/100/1000 Base-T PoE RJ-45
- Ports 1-2 : 802.3 af/at/bt 60W
- Ports 3-8 : 24V Passive/48V 802.3af/at PoE
- Uplink Port 2*1000 Base-X SFP
- Console 1*RJ-45 to RS-232 console port (115200,8,N,1)
- AL+, AL- Alarm output
- IN Alarm input
- TMS Temperature sensor interface
Buttons
- Ring Set By pressing the button over 5s, the switch will enable the fast ring mode.
- RET (Reset) By pressing the button over 5s, the switch will be restored to the original factory default setting.
LED Indicators
PWR (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
V1/V2 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
9, 10(SFP Indicator)
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
Ring
- Off: The fast ring mode is disable.
- On: The fast ring mode is enable.
Power Supply
Input Power
- V1 (Main): DC 37~57V , 10A Max
- V2 (Backup): DC 37~57V, 10A Max
- Boost Power: DC 9~52V,10A Max
WI-PS206-I
Interfaces
Ethernet Port
- 4*10/100 Base-TX PoE RJ-45 ports
- Ports 1 : 802.3 af/at/bt 90W
- Ports 2-4: 802.3 af/at PoE
- Fiber Port 2*10/100 Base-TX RJ-45 ports
DIP Switch Mode
- PoE Watchdog PoE watchdog, all PoE ports enable PoE watchdog function, which can detect and reboot the offline compliant PoE powered devices.
- EX_1-2 The transmission distance of port 1-2 can be up to 250m, but the rate is limited to 10Mbps.
- EX_1-4 The transmission distance of port 1-4 can be up to 250m, but the rate is limited to 10Mbps.
- VLAN All downlink ports are isolated from each other, but can communicate with uplink ports.
LED Indicators
PW (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
V1/V2/V3 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2/V3 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
VLAN
- Off: VLAN mode is disable.
- On: VLAN mode is enable.
Extend
- Off: Extend mode is disable.
- On: Extend mode is enable.
Power Supply
Input Power
- V1 (Main): DC 37~57V, 5.2A Max
- V2 (Backup): DC 37~57V, 5.2A Max
- V3 (DC Jack): DC 37~57V, 5.2A Max
WI-PS208-I
Interfaces
PoE Port
- 8*10/100 Base-TX PoE RJ-45 ports
- Ports 1-2 : 802.3 af/at/bt 90W
- Ports 3-8: 802.3 af/at PoE
DIP Switch Mode
- PoE Watchdog, all PoE ports enable PoE watchdog function, which can detect and reboot the offline compliant PoE-powered devices.
- EX_1-4 The transmission distance of port 1-4 can be up to 250m, but the rate is limited to 10Mbps.
- EX_1-6 The transmission distance of port 1-6 can be up to 250m, but the rate is limited to 10Mbps.
- VLAN All downlink ports are isolated from each other, but can communicate with uplink ports.
LED Indicators
PW (Power indicator)
- Off: the device is power off or failed
- On: the device power on is normal
V1/V2/V3 (Input power indicator)
- Off: No power supply
- On: Power is supplying via V1/V2/V3 DC connector
Link Indicator
- Off: ports link down
- On: ports link up
- Blinking: data on TX/RX
PoE Indicator
- Off: PoE not working
- On: PoE working
VLAN
- Off: VLAN mode is disable.
- On: VLAN mode is enable.
Extend
- Off: Extend mode is disable.
- On: Extend mode is enable.
Power Supply
Input Power
- V1 (Main): DC 37~57V, 10A Max
- V2 (Backup): DC 37~57V, 10A Max
- V3 (DC Jack): DC 37~57V, 10A Max
DIN-rail Installation
Please follow the steps below.
Step 1: Install the switch to the DIN rail.
Accessories
- Null
DC Power Cable Connection
- Before installation, ensure that the device is disconnected from the power supply.
- Connect one end of the protective grounding cable to the grounding screw on the side panel of the device, and the other end is well grounded nearby.
- Connect the positive and negative wires of DC power separately to the “+” and “-” power terminal of 37~57V power 1 or 37~57V power 2 on the switch as following figure, using screwdriver to screw stably.
- The redundant power can be both connected with the DC power, so that one power supply can still work in case the other one fails.
- Turn on the DC power, and check if power supply indicator of power 1 or power 2 turns on, which means the main power (Power 1) or backup power (Power 2) is connected correctly.
- If the switch work with 12~37V DC input power, it will work as a non-PoE switch.
Note
For WI-PS305G-I-DC, WI-PMS310GF-Alien-I, the boost power interface can work
with 9~52V 10A max DC power
Login WEB UI
For more L2 management functions, please login the Web-Based UI as the following steps:
- Step 1. Find the IP address of the switch.
- The default login IP address of this series switch is 192.168.0.1, with a subnet mask of 255.255.255.0.
- If the switch receive an IP address from a DHCP server in your network. You can find this · IP address on the DHCP server.
- Step 2. Configure IP address on your PC to make sure the switch and PC are in the same subnet.
- If the switch uses the static IP address of 192.168.0.1, configure your PC’ s IP address as 192.168.0.x (“ x ” ranges from 2 to 254), and subnet mask as 255.255.255.0.
- If the switch uses an IP address assigned by a DHCP server, set your PC to obtain an IP · address automatically from the DHCP server.
- Step 3. Launch a web browser on your PC. Enter the IP address of the switch in the address bar and fill in the username and password.
- The default login username and password are both “admin”.
Warranty Card
- If the product defects within three months after purchase, we will provide you a new product of the same model.
- If the product defects within the three-year warranty period, we will provide professional maintenance service.
- Proof of purchase and a complete product serial number are required to receive any services guaranteed as part of the limited warranty.
- Any other defects that are not caused by workmanship or product quality, such as natural disaster, water damage, extreme thermal or environmental conditions. sticker damaged, warranty card losing will disqualify the product from limited warranty.
Technical Support
Cloud Management
Company Website
Wireless-Tek Technology Limited
- Address: Biaofang Technology Building 402, Bao’an street,
- Baoan District,Shenzhen City, Guangdong, China
- Website:www.wireless-tek.com
- Tel:86-0755-32811290
- Email:sales@wireless-tek.com
- Technical Support:tech@wireless-tek.com
WI-PS302GF-I / WI-PS306GF-I / WI-PS310GF-I / WI-PMS305GF-I WI-PMS306GF-I / WI- PMS312GF-I / WI-PS305G-I-DC WI-PMS310GF- Alien-I / WI-PS206-I / WI-PS208-I www.wireless-tek.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>