ELBA EWH-K3420 Acqua Series Instant Water Heater Owner’s Manual

June 6, 2024
ELBA

ELBA EWH-K3420 Acqua Series Instant Water Heater

Thank you for purchasing ELBA Instant Water Heater. Please read this manual thoroughly and understand the content before use.

SAFETY PRECAUTION

  1. Do not install the INLET & OUTLET and Stop Valve of the heater wrongly.
  2. Do not install the heater where there is consistent spray directly over the unit.
  3. Do not connect the OUTLET to any tap or fitting that is not recommended by the manufacturer.
  4. Do not block the heater OUTLET in any way.
  5. Do not attempt to repair the heater without a qualified technician.
  6. This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  7. Children should be supervised to ensure that they do not play with the appliance.
  8. Engage a qualified electrician for installation.
  9. Test water temperature with hand before using the shower.
  10. Check the ELCB once a month (please refer to the Test Run of Heater) and consult professional for repair if there is any malfunction.
  11. Metallic / chrome flexible hose and conductive control valve shall not be used.
  12. Use only new hoses to connect the appliance to the water supply. The old hose-sets should not be reused.
  13. This appliance is not to be used as a portable water supply.
  14. The water inlet of this appliance shall not be connected to inlet water obtained from any other water heating system.
  15. Do not leave the hand shower idle in the pail. (refer below)

WATER HEATER PARTS IDENTIFICATION

EXTERNAL PARTS IDENTIFICATION

INTERNAL PARTS IDENTIFICATION

GENERAL INFORMATION

INSTALLATION

| CAUTION: THIS APPLIANCE MUST BE EARTHED
---|---

  1. All plumbing work should be completed before proceeding to electrical wiring connection. (Table 1)
  2. Installation must be carried out by a qualified electrician with close reference to this manual and in compliance with the local regulations.
  3. The unit works at a minimum water flow rate of 2.0 litre/min, which then would trigger the built-in pump (only for pump model), boostering a stronger shower spray.
  4. The built-in electronic Earth Leakage Circuit Breaker (ELCB) would cut-off the power supply to heater in the event of a current leakage as low as 15mA.
  5. The Thermal Cut-Off would automatically shut off the power supply shall there be any abnormal rise of showering temperature.
  6. The unit only operates when there is sufficient water flow to trigger the flow switch.
  7. Electrical loading Table 1:
    Voltage (Vac)| Power (kW)| Amperes (A)| Recommended Conductor Size (csa)| Fuse/MCB (A)| ON/OFF
    Switch (A)
    ---|---|---|---|---|---
    mm2| Conduit Cable| Flexible Cable

220 –50/60Hz

| 3.5| 16.0| 2.5| 7/0.67mm| 50/0.25| 20| 20
4.5| 20.5| 2.5| 7/0.67mm| 56/0.30| 25| 25
5.5| 25.0| 4.0| 7/0.85mm| 56/0.30| 32| 32
6.0| 27.3| 4.0| 7/0.85mm| 56/0.30| 32| 32
6.5| 29.6| 4.0| 7/0.85mm| 84/0.30| 32| 32
7.5| 34.1| 6.0| 7/1.04mm| 84/0.30| 40| 40
8.0| 36.4| 6.0| 7/1.04mm| 84/0.30| 40| 40
230 –50/60Hz| 3.5| 15.2| 2.5| 7/0.67mm| 50/0.25| 20| 20
5.5| 24.0| 4.0| 7/0.85mm| 56/0.30| 32| 32
6.6| 28.7| 4.0| 7/0.85mm| 56/0.30| 32| 32
8.8| 28.3| 6.0| 7/1.04mm| 84/0.30| 40| 40
240 – 50/60Hz| 3.6| 15.0| 4.0| 7/0.67mm| 50/0.25| 32| 20
3.8| 16.3| 4.0| 7/0.67mm| 50/0.25| 32| 20
4.2| 17.5| 4.0| 7/0.67mm| 50/0.25| 32| 20
7.7| 32.1| 6.0| 7/1.04mm| 84/0.30| 40| 40
9.0| 37.5| 6.0| 7/1.04mm| 84/0.30| 40| 40
8. Instantaneous water heater shall be equipped with a 2-pole control switch and its own residual current device. 9. Water heaters exceeding 3kW shall be permanently connected to a 20A/30A rated circuit breaker/fuse with an isolator switch and residual current device.

INSTALLATION PROCEDURES

  1. All the plumbing works should be completed before proceeding to electrical wiring connection.

  2. INLET and OUTLET connection of the heater unit should not be reversed, with stop valve installed on INLET. (Diagram 1).

  3. It is recommended to mount the unit at 1.5mm above the floor to bottom of the heater.

  4. Mounting position (Refer Diagram 2).
    • Remove screw from the bottom of the heater
    • Lift the plastic cover upward
    • Mark mounting position on the wall for all 4 screws
    • Drill the holes with 5.0mm diameter drill bit (Refer Diagram 3)
    • Install the unit to the wall with plu

  5. Installation of Heater INLET and OUTLET connection.
    a) Connect the stop valve to INLET, and be sure to put a gasket to prevent water leakage.
    b) Connect the piping from the stop valve to incoming water supply. If necessary make use of sealing tape for the connection to prevent water leakage.
    c) Connect flexible hose to heater OUTLET. Turn on the water mains to drain out all the plumbing dirt and fill up the heater tank. Then, connect the flexible hose to the hand shower.


    ( Note: This step will prevent damage to the heating element).

  6. Electrical Connection

    SWITCH OFF THE MAIN SUPPLY BEFORE ELECTRICAL WORK
    a) Insert electrical cable through the rubber grommet as shown.
    b) Connect the cable to the terminal block and fully tighten them as the following:-
    • Red or Brown ……………………………….…… Live (L)
    • Black or Blue.……………………………….…….. Neutral (N)
    • Green or Green/Yellow……………………………Earth
    c) Restore the cover and secure screw at the bottom. ( Diagram 4)

    d) Align the knob from ‘ON’ position in clockwise direction to ‘MAX’ and return to ‘OFF’ mark as shown. (Diagram 5)

Test Run of Heater

a) Turn on the stop valve and water should spray out from the head.
b) Switch on the main power supply (POWER’ LED would light up). c) Turn on the Temperature Control andHEATER’ LED would light up. The water should be warmed in few seconds.
d) Test the ELCB by pressing TEST’ Knob switch. The unit should be tripped. POWER’ and HEATER’ LEDs would light off. e) PressRESET’ switch. The unit should resume to normal condition.
f) The heater is now ready for use.

OPERATION PROCEDURES

  1. Switch on the main power supply, the `POWER’ LED would light up.
  2. Turn on the water supply at the stop valve.
  3. Turn on the Temperature Control Knob. The HEATER’ LED would light up and the water temperature will be increased accordingly as the knob is turned clockwise fromON’ to `MAX’.
  4. For normal cold shower, just turn the Temperature Control Knob to `OFF’ position.
  5. Switch off the power supply when not in use.

GENERAL MAINTENANCE

DO NOT USE THINNER, ALCOHOL OR PETROL

You may clean the heater with a damp cloth and mild detergent but do not use thinner, alcohol, petrol or any other organic solution.

CLEAN FILTER REGULARLY (DIAGRAM 6)

a) Remove the filter mesh from the stop valve (for filter type only) by turning the knob filter counter clockwise and pulling out the knob (Diagram 6). Flush it with water to remove any trapped sediments. Install the knob filter back to its original position.

TECHNICAL SPECIFICATION

Electrical loading 3.8kW 240V 50/60Hz
Other loading Please refer Electrical loading table 1
ELCB sensitivity 15 mA
Operating condition Open system (Open outlet)
Water connection ø15mm (1/2” BSP)
Degree of protection IP25
Min water flow rate 2 litre/ min
Min water pressure 0.2 bar ( 20kPa / 2.9psi )
Max water pressure 6 bar ( 0.6MPa / 87psi )
Heater dimension (mm) 250 (H) x 236 (W) x 87 (D)
Heater nett weight 1.2kg

Notes: The specification of product design and accessories shown are correct at the time of printing and subject to change without prior notices.

SCHEMATIC WIRING DIAGRAM

NON-PUMP ( EWH-K3420(SW) / EWH-K3420(GB) )

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals