KEYSWITCH 2 POS.
UNIVERSAL SF.
TRANSLATED VERSION
Read the instructions for this product carefully. For reasons of personal
safety, it is important to follow all the instructions, as incorrect
installation can lead to serious injury.
Keep these instructions.
Any use of this product other than indicated in this documentation runs the
risk of damaging the product and creating a hazard. Somfy disclaims all
liability arising from incorrect use or not adhering to the intended use set
out in the present documentation, failure to comply with the correct frame
design (doors, gates, etc.) or any deformation that might occur in use. The
product must be installed by a competent individual (professional installer,
as per EN12635), in accordance with the correct technique and standards in
force.
Whilst leaving the essential specifications of the device unchanged, the
company reserves the right to make any modifications it deems pertinent to
improving the product from a technical, commercial or design point of view, at
any time, without undertaking to update this publication.
This product does not require any maintenance.
The altitude of the equipment’s installation site must not exceed 2000 m.
The relative air humidity must not exceed 50 % at the maximum temperature of
+40 °C.
Higher relative humidities may be permitted at lower temperatures, e.g. 90 %
at +20 °C.
**** Somfy limited, Yeadon LS19 7ZA UK hereby declares that the drive covered
by these instructions when marked for input voltage 230V~50Hz and used as
intended according to these instructions, is in compliance with UK legislation
of Machinery safety regulations S.I.2008 N°1597. The full text of the UKCA
declaration of conformity is available at
www.somfy.co.uk.
Steven MONTGOMERY, Managing Director Somfy Ltd UK & Ireland, Yeadon, 09/2022
Power supply| 12/24 Vac/dc
120-240V 50/60 Hz
---|---
Contact| 240V – AC 15 – 5A
Maximum conductor cross-section| 1.5 mm²
Standard| IEC 60947-5-1
Rated insulation voltage| 300 V
Rated impulse withstand voltage| 2.5 kV
Pollution degree| 3
Short-circuit protection| 16 A gG
Conditional short-circuit current| 16A
Operating temperature| – 5°C to + 40°C
Index protection rating| IP54
Electrical insulation class| Class I
Dimensions (mm)| 76 x 74 x 48
Operating mode| Stable – Unstable – Mixed
Cover mechanically locked, requiring you to insert the key and turn the barrel to access the wiring Supplied with 3 identical keys (European barrel)
INSTALLATION
Disassembly – fig. A
Mounting – fig. B
Make sure to fit the unit the right way round.
Operating modes – fig. C
Red T buttons engaged – Unstable – fig. C1
Green R buttons engaged – Stable – fig. C2
Mixed – fig. C3
Wiring – fig. D
Wired control (unstable mode) – fig. D1
External unlocking (stable mode) for Axovia MultiPro and Invisio- fig. D2
Direct motor control – fig. D3
Assembly – fig. E
SOMFY ACTIVITES SA
50 avenue du Nouveau Monde
74300 CLUSES
FRANCE
www.somfy.com