sOmfy 5164829B Door Lock Controller User Guide

June 10, 2024
somfy

5164829B Door Lock Controller

sOmfy-5164829B-Door-Lock-Controller-product-image

Product Information

Ref. 5164829B

Dimensions (L x h x p)

Alimentation / 1 W

Classe d’isolation

The product includes:

  • Wall control SMOOVE io
  • Remote controller KEYGO io
  • Remote controller KEYTIS io
  • Codetastatur 2 io
  • Smart Home Box io (Connexoon, TaHoma Switch)

Product Usage Instructions

4. PROGRAMMING

4.1. Wall control SMOOVE io (see Plan)

To pair the wall control with the lock controller io:

  1. Press and hold the “PROG” button on the lock controller io for 3 seconds until the green LED starts flashing.
  2. Press the “PROG” button on the SMOOVE io remote control. When the LED lights up and stops flashing, both devices are paired.
4.2. Remote controller KEYGO io (see Plan)

To lock or unlock the door:

  • Press the button corresponding to the lock on the remote control to lock or unlock the door.
  • The lock will automatically lock when the door is closed.
4.3. Remote controller KEYTIS io (see Plan)

To lock or unlock the door:

  • Press the button corresponding to the lock on the remote control to lock or unlock the door.
  • The LED will flash briefly when the lock is activated.
4.4. Codetastatur 2 io (see Plan)

To lock or unlock the door:

  • Enter the appropriate code on the keypad to lock or unlock the door.
4.5. Smart Home Box io (Connexoon, TaHoma Switch)

Please refer to the Smart Home Box io user manual for programming instructions.

4.6. Reset (see Plan)

Please refer to the product user manual for reset instructions.

5. OPERATION

5.1. SMOOVE io wall control
  • To turn on or off, press the corresponding button.
5.2. KEYGO io remote controller
  • To lock or unlock the door, press the corresponding button on the remote control.
  • The lock will automatically lock when the door is closed.
5.3. KEYTIS io remote controller
  • To lock or unlock the door, press the corresponding button on the remote control.
  • The LED will briefly flash when the lock is activated.
5.4. Codetastatur 2 io
  • To lock or unlock the door, enter the appropriate code on the keypad.
5.5. Smart Home Box io (Connexoon, TaHoma Switch)

Please refer to the Smart Home Box io user manual for operation instructions.

OPERATING CONDITIONS

Do not use this product outdoors. The radio range is limited by the regulatory standards for radio equipment. The radio range is highly dependent on the environment in which it is used: possible interference from large electrical equipment in the vicinity of the installation, type of material used in the walls and partitions of the site (metal surfaces, etc.). The use of radio equipment (e.g. hi-fi headphones) using the same radio frequency may reduce the product performance.

CONFORMITY
Hereby, Somfy declares that the radio equipment covered by these instructions complies with the requirements of the Radio Equipment Directive 2014/53/EU and other essential requirements of the applicable European Directives. The full text of the EC declaration of conformity is available at www.somfy.com/ce.

Damaged electrical and electronic products as well as spent batteries should not be disposed of with household waste. Ensure you take them to a collection facility or an authorized centre for their recycling.

RESPONSIBILITIES
Read this installation guide and the safety instructions carefully before installing this Somfy product. Follow each of the given instructions precisely and keep this guide as long as the product. This Somfy product must be installed by a professional motorization and home installer for whom this guide is intended.
The installer must also comply with the standards and legislation in force in the country of installation, and inform his customers of the conditions of use and maintenance of the product. Any use outside the scope defined by Somfy is prohibited. As with any failure to comply with the instructions contained in this guide, it would preclude Somfy’s liability and warranty. Before installation, check the compatibility of this product with associated equipment and accessories.

SAFETY INSTRUCTIONS
When used with a motor, also refer to the motor instructions. Do not install or use the product outdoors. Do not subject the product to impacts or drops, or expose it to flammable materials or a heat source, or to moisture or splashing liquid, and do not immerse it in liquid.

SPECIFICATIONS

  • Operating temperature -20°C to +60°C
  • Dimensions (L x H x D) 95 x 47 x 23 mm
  • Power supply 8 – 24 V DC / 1 W
  • Isolation class
  • Frequency bands and maximum power used
    868.000 MHz–868.600 MHz
    – e.r.p. <25 mW
    868.700 MHz–869.200 MHz
    – e.r.p. <25 mW
    869.700 MHz–870.000 MHz
    – e.r.p. <25 mW

This product is guaranteed for 5 years from the date of purchase. The general conditions of guarantee are available at: www.somfy.com

INTRODUCTION

The Lock controller io is designed to control electric locks of entry doors.

INSTALLATION AND WIRING
The Lock controller io can be clipped onto a DIN rail in an electrical switchboard or installed in a flush-mounted wall casing near the door. It comes with removable connectors for easy wiring. Cable cross-section: from 0.14 mm² to 1.5 mm².

sOmfy-5164829B-Door-Lock-Controller-01

  1. Fitting on DIN rail
    See diagram 2
    sOmfy-5164829B-Door-Lock-Controller-02

  2. Fitting in a flush-mounted casing
    Provide for access to the product at all times.
    See diagram 3sOmfy-5164829B-Door-Lock-Controller-03

  3. Wiring
    See diagram 4sOmfy-5164829B-Door-Lock-Controller-04

  • Power supply: 8 – 24 V DC / 1 W
  • Inputs: dry contact (max. 3.3 V/10 mA)
  • Outputs: dry contact (max. 24 V/1 A)
  • Outputs: dry contact (max. 24 V/2 A)
  • External antenna (optional)

DOOR PROFILE CONFIGURATION

sOmfy-5164829B-Door-Lock-Controller-11 sOmfy-
5164829B-Door-Lock-Controller-12 sOmfy-
5164829B-Door-Lock-Controller-13

  • In the case of the activation of 2 devices (example: 1 electric door opener and 1 light), outputs OUT1 and OUT3 are activated simultaneously during the activation time (microswitches 4 and 5). Output OUT 2 is activated during the activation time.
  • For a permanent unlocking (example: «passage»  mode of some electric locks): outputs OUT1 and OUT3 remain active until locking.

Example of door profile configuration:sOmfy-5164829B-Door-Lock-
Controller-15

AUTOMATIC TESTS

To check the wiring between the Lock controller io and the connected devices.

Outputs test
Briefly press the “TEST” button to activate an output for 1 second.
Press again to change the output (OUT1 > OUT 2 > OUT3 OUT1, etc.).

Inputs test
Press the “TEST” button for 2 seconds, until the orange LED flashes.
Activating the IN1 input activates the OUT1 output. The orange LED remains fixed until the IN1 input is deactivated (same as for the IN2 and IN3 inputs).
To exit the test mode, press the “TEST” button twice.3.2. Inputs test
Press the “TEST” button for 2 seconds, until the orange LED flashes.
Activating the IN1 input activates the OUT1 output. The orange LED remains fixed until the IN1 input is deactivated (same as for the IN2 and IN3 inputs).
To exit the test mode, press the “TEST” button twice.

PROGRAMMING

SMOOVE io wall control (see diagram 5 )

  1. Press the “PROG” button on the Lock controller io for 3 seconds until the green LED indicator flashes.
  2. Briefly press the “PROG” button on the SMOOVE io. When the LED becomes steady and stops flashing, the 2 devices are linked.

sOmfy-5164829B-Door-Lock-Controller-05

KEYGO io remote controller (see diagram 6  )

  1. Press the “PROG” button on the Lock controller io for 3 seconds until the green LED indicator flashes.
  2. Press the 2 external buttons on the KEYGO io simultaneously until the green LED flashes rapidly.
  3. Press the selected key to operate the door lock. When the LEDs stop flashing, the 2 devices are linked.

sOmfy-5164829B-Door-Lock-Controller-06sOmfy-
5164829B-Door-Lock-Controller-07 KEYTIS io remote controller (see diagram 7 )
First, make sure that the system key of the KEYTIS io has been correctly memorized. If this is not the case, refer to the “Memorizing the system key” step in the product guide.

  1. Press the “PROG” button on the Lock controller io for 3 seconds until the green LED indicator flashes.
  2. Briefly press the “PROG” button on the KEYTIS io. Wait for the second “BEEP” and the rapid flashing of the green LED (1 sec. to 1 min.).
  3. Press the selected key to control the door lock. When the LEDs stop flashing and a long “BEEP” sounds, the 2 devices are linked.

Code 2 keypad io (see diagram 8 )
First, make sure that the main code of the keypad has been correctly memorized. If this is not the case, refer to the “Changing the main code” step in the product guide.

  1. Press the “PROG” button on the Lock Controller io for 3 seconds until the green LED indicator flashes.
    Enter the main code on the keypad and press the 2 control keys simultaneously until the 2 LEDs flash rapidly.
    Press the selected key to control the door lock. When the LEDs stop flashing and a long “BEEP” sounds, the 2 devices are linked.

sOmfy-5164829B-Door-Lock-Controller-08

“Connected router ” io (Connexoon, TaHoma Switch)
Option 1

  • Press the “PROG” button on the Lock controller io for 3 seconds until the green LED indicator flashes.
  • Briefly press the “PROG” button of the connected router io. When the LED becomes steady and stops flashing, the 2 devices are linked.

Option 2 (see diagram 9 )

  • Download the application of the connected router.
  • Press (3 s) the “PROG” button on the Lock controller io until the green LED indicator flashes.
  • Follow the instructions in the application to link the Lock controller io. When the LED becomes steady and stops flashing, the 2 devices are linked.

sOmfy-5164829B-Door-Lock-Controller-09

Resetting (see diagram 10 )
To unlink all devices, press the “PROG” button on the Lock controller io for 7 seconds.
The green LED first lights up steadily, flashes 5 times normally, 3 times rapidly, then goes off.

sOmfy-5164829B-Door-Lock-Controller-10

OPERATION

SMOOVE io wall control
Profile: Door lock with locking and unlocking

  • Pressing the “^” key unlocks the lock, outputs 1 and 3 are activated.
  • Pressing the “v” key locks the lock, output 2 is activated.
  • Pressing the “my” key has no effect.

Profile: Door lock with unlocking only

  • Pressing the “^” key unlocks the lock, 3 outputs 1 and 3 are activated. When closing the door, the lock locks automatically.
  • Press the “^” key again to unlock the lock.
  • Pressing the “my” and “v” keys has no effect.

KEYGO io remote controller
Profile: Door lock with locking and unlocking 321 Pressing the lock control button locks (output 2) or unlocks (outputs 1 and 3) the lock, depending on the last action performed.
Pressing the button again triggers the next action (unlocking or locking).

Profile: Door lock with unlocking only
Pressing the dedicated button unlocks the lock, outputs 1 and 3 are activated.
When closing the door, the lock locks automatically. Pressing the dedicated button again unlocks the lock.

KEYTIS io remote controller
Profile: Door lock with locking and unlocking

  • Pressing the lock control button locks (output 2) or unlocks (outputs 1 and 3) the lock, depending on the last action performed. Pressing the button again triggers the next action (unlocking or locking). In both cases, the LED flashes briefly.
  • Within 30 seconds after the locking and unlocking operations, the LED of the KEYTIS io flashes green (action completed) or red (action not completed). Only possible if the open/close or lock sensors are present:sOmfy-5164829B-Door-Lock-Controller-16

Profile: Door lock with unlocking only ****

  • Pressing the dedicated button 32 1 unlocks the lock, outputs 1 and 3 are activated. The LED flashes briefly and a “beep” is heard.
  • When closing the door, the lock locks automatically. Pressing the dedicated button again unlocks the lock.

Code 2 keypad io
Profile: Door lock with locking and unlocking ****

  • Enter the main code and press the lock control button. This locks (output 2) or unlocks (outputs 1 and 3) the lock, depending on the last action performed.
  • Enter the code and press the button again to  trigger the next action (unlock or lock).

Profile: Door lock with unlocking only ****

  • Enter the main code and press the dedicated button to unlock the lock. Outputs 1 and 3 are activated.
  • When closing the door, the lock locks automatically. Enter the code and press the dedicated button again to unlock the lock.

“Connected router ” io (Connexoon, TaHoma Switch)
Profile: Door lock with locking and unlocking ****

  • From the application of the connected router, press the dedicated icon to lock or unlock the lock.

Profile: Door lock with unlocking only

  • From the application of the connected router, press  the dedicated icon to unlock the door.
  • When closing the door, the lock locks automatically. Press on the dedicated icon again to unlock the lock.
  • To integrate the unlocking and locking of the lock into scenarios, please refer to the operating manual of the connected router io.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals