LiGHTPRO Erba 222P Standing Lamp User Manual
- June 9, 2024
- LiGHTPRO
Table of Contents
LiGHTPRO Erba 222P Standing Lamp
CONNECTION
Product Information
The Lightpro Erba and Erba Mid are standing LED lamps designed for outdoor use. They come with ground stakes for easy installation and are compatible with the Lightpro 12-volt system. The lamps are equipped with non-replaceable LED bulbs that have a maximum power consumption of 1.1W and a maximum light output of 100 lumens. They have a color temperature of 3000K and an average lifespan of 25,000 hours. The lamps are not dimmable and have an IP44 protection rating.
PRODUCT DESCRIPTION
The Lightpro Erba / Erba Mid is a standing LED lamp for outdoor use. The
fixture can be placed in the ground with the plugs provided. This product may
only be used as outdoor lighting in combination with the Lightpro 12-volt
system. Any alterations made to the product may have consequences for the
safety, guarantee and correct functioning of the product and/or other parts of
the system.
Package Contents
- Lightpro Erba or Erba Mid lamp
- Ground stake(s)
- Lightpro connector(s) F
Specifications
- Product: Lightpro Erba / Erba Mid
- Article number: 222P / 223P
- Light source: LED 1.1W AC/DC 12V
- Power (max.): 1,1W
- Luminous flux (max): 100 lm
- Light colour: 3.000K
- Average lifetime: 25.000 Hours
- Dimensions (H x Ø): Small 564 x 20 mm Medium 734 x 20 mm Large 904 x 20 mm
- Maximum power consumption: 1.1W
- Maximum light output: 100 lm
- Color temperature: 3000K
- Average lifespan: 25,000 hours
- Protection rating: IP44
- Erba Mid (H x Ø); 734 x 20 mm
- Protection class: IP44
- Ambient temperature: 20°C to 50°C
- Cable length: 1m
- Dimmable: No
- Light source replaceable: No
- On/off cycles: 10,000
Product Usage Instructions
- Read the user manual carefully before using the product.
- Check that all parts are present in the packaging.
- Connect the Lightpro connector(s) F to the transformer (144A/145A).
- Twist and connect the Lightpro connector(s) M to create a branch if necessary.
- Connect the Lightpro connector type Y (143A) to the lamp.
- Turn the staker on the lamp to attach it.
- Insert the ground stake(s) into the desired location in the ground.
- Ensure that the lamp is properly connected to the 12-volt system.
- Turn on the power to the transformer and enjoy your outdoor lighting!
Erba / Erba Mid
User manual
Thank you for purchasing the Lightpro Erba / Erba Mid. This document contains
the required information for correct, efficient and safe use of the product.
Consult the user manual of your transformer for more information about the
installation and connection of your lighting plan or visit our website
www.lightpro.nl Read the information in this manual
carefully before using the product. Keep this manual near the product for
consultation in the future.
WARNING: Check if all parts are present in the packaging. For questions about parts, service, and any complaints or other remarks, you can always contact us.
E-mail: info@lightpro.nl
INSTALLATION
INSTALLATION IN THE GROUND
- Screw the plug [2] to the fixture [1].
- Insert the plug at the desired location in the ground.
INSTALLATION OF THE LIGHTS
- Install the products in the desired position and lay the cables so they can be comfortably connected to the transformer or main cable.
- If products are provided with a drain hole for water, this hole must be pointing downwards.
- Use non-corrosive fixing materials (supplied as standard) if you want to bolt the products down.
- Connect the lights to the main cable by using the connector as shown in figure on page 5.
- Consult the manual of your transformer for more information.
SAFETY
- Always fit this product so that it can still be accessed for servicing or maintenance. This product must not be permanently embedded or bricked in.
- Turn off the system by pulling the plug of the transformer from the socket for maintenance.
- Regularly clean the product with a soft, clean cloth. Avoid abrasives that can damage the surface.
- Clean products with stainless steel parts with a stainless steel cleaning agent once per six months.
- Do not use a high pressure washer or aggressive chemical cleaning agents when cleaning the product. This can cause irreparable damage.
- Protection class III: this product may only be connected to safety extra-low voltage up to a maximum of 12 Volt.
- This product is suitable for outside temperatures of:
- 20 to 50 °C.
- Do not use this product in areas where combustible gases, fumes or liquids may be stored.
The product meets the requirements of the applicable EC, UK and EAEU
guidelines.
For questions about parts, service, any complaints or other matters, you can
contact us at any time.
E-mail: info@lightpro.nl
Discarded electrical equipment must not be put in the household waste. If possible, take it to a recycling company. For details of recycling, contact a municipal waste processing company or your dealer. 6 year warranty – visit our website at lightpro.nl for warranty conditions.
UK Authorised Representative (for authorities only) ProductIP (UK) Ltd. 8,
Northumberland Av. London WC2N 5BY
TECHMAR B.V. | CHOPINSTRAAT 10 | 7557 EH HENGELO | THE NETHERLANDS |
WWW.LIGHTPRO.NL
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>