LiGHTPRO 102U Agate Ground Spot User Manual

June 9, 2024
LiGHTPRO

LiGHTPRO 102U Agate Ground Spot User Manual

Agate

User manual

Thank you for purchasing the Lightpro Agate. This document contains the required information for correct, efficient and safe use of the product. Consult the user manual of your transformer for more information about the installation and connection of your lighting plan or visit our website www.lightpro.nl

Read the information in this manual carefully before using the product. Keep this manual near the product for consultation in the future.

PRODUCT DESCRIPTION
The Lightpro Agate is an LED spot for outdoor use. The fixture can be installed in a fixed underground. This product may only be used as outdoor lighting in combination with the Lightpro 12-volt system. Any alterations made to the product may have consequences for the safety, guarantee, and correct functioning of the product and/or other parts of the system.

SPECIFICATIONS

  • Product :Lightpro Agate

  • Article number :102U

  • Light source :MR16 Led GU5.3 3W AC/DC 12V

  • Power (max) :3W

  • Luminous flux (max) :230 lm

  • Light colour :3.000K

  • Average lifetime :25.000

  • Dimensions :(H x Ø) 113 x 90 mm

  • Protection class :IP67

  • Ambient temperature – : 20 °C to 50 °C

  • Cable length :0,5m

  • Dimmable :No

  • Light source :Replaceable

PACKAGING CONTENT

[Figure A]
PACKAGING CONTENT

  1. Fixture Agate
  2. Tube
  3. Hex key
  4. Lightpro connector 137a

Check if all parts are present in the packaging. For questions about parts, service, and any complaints or other remarks, you can always contact us. E-mail: [email protected].

INSTALLATION

[Figure B] INSTALLATION

  1. Install the products in the desired position and lay the cables so that they can be comfortably connected to the transformer or cables.
  2. If products are provided with a drain hole for water, this hole must be pointing downwards.
  3. Use non-corrosive fixing materials (supplied as standard) if you want to bolt the products down.
  4. Connect the lights to the main cable by using the connector as shown on page 5.
  5. Plug the plug of the transformer into the wall socket (230 Volt 50 Hz).

REPLACEABLE LIGHTSOURCE
[Figure C]REPLACEABLE LIGHTSOURCE

Proceed as follows in order to install or change the light source:

  1. Turn the power off.
  2. Let the light source cool down for at least 5 minutes.
  3. Replace the light source, bearing the following points in mind:
    • Only replace the light source by an identical model with the same specifications.
    • When (re)assembling, ensure that the parts are dry and clean.
  4. Turn the power back on.

REPLACEABLE LIGHTSOURCE

Proceed as follows if the lamps do not light after you have followed the above instructions:

  1. Turn the power off.
  2. Check whether all plugs have been connected properly.
  3. Check the light source(s) and replace them if necessary.
  4. Check the transformer and the fuse (if applicable, and have them circuit-tested if necessary).
  5. Check whether cables have been damaged.
  6. Turn the power back on.

Note: The rubber ring must be completely clean before replacing the glass because of the water resistance.

INSTALLATION OF THE LIGHTS

  • Install the products in the desired position and lay the cables so they can be comfortably connected to the transformer or main cable.
  • If products are provided with a drain hole for water, this hole must be pointing downwards.
  • Use non-corrosive fixing materials (supplied as standard) if you want to bolt the products down.
  • Connect the lights to the main cable by using the connector as shown in figure on page 5.
  • Consult the manual of your transformer for more information.

SAFETY

  • Always fit this product so that it can still be accessed for servicing or maintenance. This product must not be permanently embedded or bricked in.
  • Turn off the system by pulling the plug of the transformer from the socket for maintenance.
  • Regularly clean the product with a soft, clean cloth. Avoid abrasives that can damage the surface.
  • Clean products with stainless steel parts with a stainless steel cleaning agent once per six months.
  • Do not use a high pressure washer or aggressive chemical cleaning agents when cleaning the product. This can cause irreparable damage.
  • Protection class III: this product may only be connected to safety extra-low voltage up to a maximum of 12 Volt.
  • This product is suitable for outside temperatures of: -20 to 50 °C.
  • Do not use this product in areas where combustible gases, fumes or liquids may be stored.

 This product meets the EU standards for health, safety and environmental protection.
For questions about parts, service, any complaints or other matters, you can contact us at any time. E-mail: [email protected]
Discarded electrical equipment must not be put in the household waste. If possible, take it to a recycling company. For details of recycling, contact a municipal waste processing company or your dealer.
5 year warranty – visit our website at lightpro.nl for warranty conditions.

Symbol

  • UK Authorised Representative
  • (for authorities only)
  • ProductIP (UK) Ltd.
  • 8, Northumberland Av.
  • London WC2N 5BY

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals