These instructions will be updated from time to time due to product version upgrades or for other reasons. Unless otherwise specified, they are not a substitute for the safety instructions given on product labels or in user manuals. All descriptions in the document are intended only as user instructions.


01 Technical Data
Module 4G Kit-AF
Power supply(V) 5V
Self-consumption (W) <4W
Operating temperature -30°C to +60°C
Operating humidity 0 – 100% RH
Altitude ≤4000m
Size (LxWxH) 96mm49mm32mm
Protection class IP65
LTE-FDD B2/B4/B5/B12/B13/B14/B66/B71
LTE-TDD N/A
WCDMA B2/B4/B5
GSM/GPRS N/A
Certification FCC
LTE-FDD(Mbps) 150 (DL)/ 50 (UL)
LTE-TDD(Mbps) N/A
WCDMA(Kbps) 384 (DL)/ 384 (UL)
GPRS(Kbps) N/A
02 Applications

GOODWE 4G Kit-AF - QR Code 2 NOTE

Information regarding the SIM operators, inverter models and versions supported by 4G modules will be updated from time to time, and the latest support details can be obtained by scanning the QR code.
Download the latest version of PV Master App and SEMS Portal APP from Google Play or App Store.


Near-Field Bluetooth Configuration with APN

4G Kit-AF - Applications 1

4G Communication Networking

4G Kit-AF - Applications 3

  1. Bluetooth module
  2. PV Master App
  3. 4G module
  4. SEMS
  5. SEMS Portal APP
03 Installation and Commissioning
Installing Bluetooth module

NOTE

  • When installing the Bluetooth and 4G modules, make sure the inverter is powered off.

  • During installation, wear antistatic gloves, and take electrostatic protection measures.

1. Check that the items delivered are correct.

1 x 4G module
1 x Bluetooth module
1 x 4G antenna
1 x Removing tool
2 x Quick Installation Instructions

| 2. Install Bluetooth module.

USB Communication Interface

---|---

Setting APN parameters

NOTE

Before setting the parameters, make sure that:

  1. The inverter is powered on.
  2. Communication is functioning properly between Bluetooth module and inverter.
  3. The PV Master App has been downloaded from Google Play or App Store. (PV Master with V4.3.2 or newer version is required. )
  4. The procedure is basically identical for Android and iOS operating systems, with only slight difference between the interfaces. These instructions use the iOS operating system as an example.
  5. Please use the initial password when logging in for the first time, and change it as soon as possible to one that is memorable for you. To keep your account secure, it is recommended to change your password regularly.

GOODWE 4G Kit-AF - QR Code 3PV Master App


4G Kit-AF - Setting APN parameters 1 4G
Kit-AF - Setting APN parameters 2 4G
Kit-AF - Setting APN parameters 3

4G Kit-AF - Setting APN parameters 4 4G
Kit-AF - Setting APN parameters 5 4G
Kit-AF - Setting APN parameters 6

4G Kit-AF - Setting APN parameters 7 4G
Kit-AF - Setting APN parameters 8

Installing 4G module

NOTE

  • When installing the Bluetooth and 4G modules, make sure the inverter is powered off.

  • During installation, wear antistatic gloves, and take electrostatic protection measures.

OUT-GRC-HD2BL - CAUTION

The 4G antenna cable is connected to the enclosure, so take care not to damage the cable when removing.

| 4G Kit-AF - Installing 4G module 2| Inverter USB Interface

4G Kit-AF - Installing 4G module 6

---|---|---
| 4G Kit-AF - Installing 4G module 4| 4G
Kit-AF - Installing 4G module 5

Powering on the device
  1. Power on the inverter, thus powering on the 4G module.
  2. Observe the status of the indicators on the 4G module and the inverter. (When the communication indicator on the inverter is ON continuously, it means that communication is functioning properly. For other indicator status, refer to the User Manual of the relevant inverter model.)

Indicator

| Colour| Status|

Notes

| Description
---|---|---|---|---

Power

|

Green

| ON continuously| Normal| Module powered on
OFF| Abnormal| Module not powered on

Communication

|

Blue

| Flashing slowly
(On for 0.2s, Off for 1.8s)| Normal| Searching for connections
Abnormal| Staying off for 15 seconds after illuminating, which indicates the SIM card is not inserted or it has a loose connection. Insert the SIM card, or remove it and then re-insert.
Flashing slowly
(On for 1.8s, Off for 0.2s)| Normal| Standby
Abnormal| If the indicator stays in this state for an extended period (more than 5 minutes), the APN is set incorrectly, the SIM card has no signal, the signal strength is weak, or there is no data. Please check the APN information and reset the APN parameters on the PV Master App. Contact the operator to verify the SIM card signal. Check whether the SIM card credit and data are sufficient. If not, please top up.
Flashing rapidly
(On for 0.125s, Off for 0.125s)| Normal| Data uploading

04 Device Replacement

4G Kit-AF - Device Replacement

  1. Before replacing the 4G module, check that the inverter is powered down, and the new 4G module is ready for installation.
  2. Use the special tool supplied to remove 4G module.
  3. (Optional) If SIM card is bound to an existing device, consult the operator to unbind it.
  4. Install the new 4G module.
  5. Power on the inverter.