true STR2RRT-2G-2S 68 Inch Two Section Roll Thru Refrigerator Instruction Manual
- June 4, 2024
- TRUE
Table of Contents
- true STR2RRT-2G-2S 68 Inch Two Section Roll Thru Refrigerator
- How to Maintain Your True Refrigerator to Receive the Most Efficient and
- ENTRAPMENT
- BEFORE YOU THROW AWAY YOUR OLD REFRIGERATOR OR FREEZER
- REPLACEMENT PARTS
- HOW TO CONNECT ELECTRICITY
- USE OF ADAPTER PLUGS
- INSTALLATION
- LOCK AND KEYS
- HOW TO CONNECT ELECTRICITY
- ELECTRIC INSTALLATION & SAFETY INFORMATION
- ELECTRICAL INSTRUCTIONS
- TRUE RECOMMENDS THAT A SOLE USE CIRCUIT BE DEDICATED FOR THE UNIT.
- WIRE GAUGE CHART
- LOCATING
- LEVELING
- SEALING CABINET TO FLOOR
- NSF APPROVED SEALANTS
- ROLL-IN & ROLL-THRU RAMP INSTALLATION
- DOOR SWEEP GASKET ADJUSTMENT
- SETUP
- OPERATION
- DIGITAL TEMPERATURE DISPLAY
- MECHANICAL TEMPERATURE CONTROLS
- MECHANICAL TEMPERATURE CONTROL GENERAL SEQUENCE OF OPERATION
- WHEN TO MAKE AN ADJUSTMENT TO A MECHANICAL TEMPERATURE CONTROL
- OPERATION INSTRUCTIONS REQUIRED TOOLS
- INSTALLATION INSTRUCTIONS
- DANFOSS TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE APPLICATIONS
- INSTALLATION INSTRUCTIONS TEMPERATURE CONTROL ALTITUDE ADJUSTMENT:
- DEFROST TIMER
- SETTING THE TIMER:
- ADJUSTING THE DEFROST TIMER
- ELECTRONIC TEMPERATURE CONTROLS
- ELECTRONIC CONTROL GENERAL SEQUENCE OF OPERATION
- HOW TO DIAGNOSE AN LAE ELECTRONIC CONTROL
- HOW TO LOCK AND UNLOCK LAE CONTROLLER
- HOW TO TURN OFF THE LAE ELECTRONIC CONTROL:
- HOW TO TURN THE GLASS DOOR MODEL LIGHT ON AND OFF
- HOW TO CHANGE THE SET POINT
- INITIATE A MANUAL DEFROST
- CHANGING DEFROST INTERVALS
- HOW TO CHANGE DEFROST INTERVALS
- HOW TO CHANGE DISPLAY READOUT FROM FAHRENHEIT TO CELSIUS:
- HOW TO DISPLAY PROBE TEMPERATURES
- DISPLAY CODES
- MAINTENANCE, CARE, CLEANING
- Spec Series models
- HOW TO CLEAN THE CONDENSER
- CAUTION MUST BE USED TO AVOID EYE INJURY EYE PROTECTION IS RECOMMENDED
- STAINLESS STEEL EQUIPMENT CARE AND CLEANING
- STAINLESS STEEL OPPONENTS
- RECOMMENDED CLEANERS FOR CERTAIN SITUATIONS / ENVIRONMENTS OF STAINLESS
- 8 STEPS THAT CAN HELP PREVENT RUST ON STAINLESS STEEL
- GENERAL MAINTENANCE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
true STR2RRT-2G-2S 68 Inch Two Section Roll Thru Refrigerator
NOTICE TO CUSTOMER
Loss or spoilage of products in your refrigerator/freezer is not covered by
warranty. In addition to following recommended installation procedures you
must run the refrigerator/freezer 24 hours prior to usage.
SAFETY INFORMATION
How to Maintain Your True Refrigerator to Receive the Most Efficient and
Successful Operation
You have selected one of the finest commercial refrigeration units made. It is manufactured under strict quality controls with only the best quality materials available. Your TRUE cooler when properly maintained will give you many years of trouble-free service.
WARNING
Use this appliance for its intended purpose as described in this Owner Manual.
TO LOCATE REFRIGERANT TYPE, SEE SERIAL LABEL INSIDE CABINET
This cabinet may contain fluorinated greenhouse gas covered by the Kyoto Protocol (please refer to cabinet’s inner label for type and volume, GWP of 134a= 1,300. R404a= 3,800).
FOR HYDROCARBON REFRIGERATION ONLY R-290
DANGER
Risk of fire or explosion
- Flammable refrigerant used.
- Do not use mechanical devices to defrost refrigerator.
- Do not puncture refrigerant tubing.
- To be repaired only by trained service personnel.
- Do not puncture refrigerant tubing.
- Consult repair manual/owner’s guide before attempting to service this product.
- All safety precautions must be followed.
CAUTION
Risk of fire or explosion
- Dispose of properly in accordance with federal or local regulations.
- Flammable refrigerant used.
- Risk of fire or explosion due to puncture of refrigerant tubing; follow handling instructions carefully.
- Flammable refrigerant used.
- Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building in.
SAFETY PRECAUTIONS
When using electrical appliances, basic safety precautions should be followed,
including the following
- This unit must be properly installed and located in accordance with the Installation Instructions before it is used.
- Do not allow children to climb, stand or hang on the shelves in the refrigerator.
- They could damage the unit and seriously injure themselves.
- Do not touch the cold surfaces in the freezer compartment when hands are damp or wet.
- Skin may stick to these extremely cold surfaces.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Keep fingers out of the pinch point areas; clearances between the doors and between the doors and cabinet are necessarily small; be careful closing doors when children are in the area.
- Unplug the refrigerator before cleaning and making repairs.
- Setting temperature controls to the 0 position does not remove power to the light circuit, perimeter heaters, or evaporator fans.
- While cleaning condenser coil lift and hold top louvered grill. Any servicing to condensing unit remove top louvered grill.
NOTE
We strongly recommend that any servicing be preformed by a qualified
technician.
RISK OF CHILD
ENTRAPMENT
PROPER DISPOSAL OF THE REFRIGERATOR
Child entrapment and suffocation are not problems of the past. Junked or
abandoned refrigerators are still dangerous… even if they will sit for just a
few days. If you are getting rid of your old refrigerator, please follow the
instructions below to help prevent accidents.
BEFORE YOU THROW AWAY YOUR OLD REFRIGERATOR OR FREEZER
- Take off the doors.
- Leave the shelves in place so that children may not easily climb inside.
APPLIANCE DISPOSAL
When recycling appliance please make sure that the refrigerants are handled according to local and national codes, requirements and regulations.
REFRIGERANT DISPOSAL
Your old refrigerator may have a cooling system that uses Ozone Depleting chemicals. If you are throwing away your old refrigerator, make sure the refrigerant is removed for proper disposal by a qualified service technician. If you intentionally release any refrigerants you can be subject to fines and imprisonment under provisions of the environmental regulations.
USE OF EXTENSION CORDS
NEVER USE AN EXTENSION CORD! TRUE will not warranty any refrigerator that has been connected to an extension cord.
REPLACEMENT PARTS
- Component parts shall be replaced with like components.
- Servicing shall be done by authorized service personnel, to minimize the risk of possible ignition due to incorrect parts or improper service.
- Lamps must be replaced by identical lamps only.
- If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
HOW TO CONNECT ELECTRICITY
- DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE GROUND PRONG FROM THE POWER CORD. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
- The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard.
- Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
- If the outlet is a standard 2-prong outlet, it is your personal respon-sibility and obligation to have it replaced with the properly grounded wall outlet.
- The refrigerator should always be plugged into it’s own individual electrical circuit, which has a voltage rating that matches the rating plate.
- This provides the best performance and also prevents overloading building wiring circuits which could cause a fire hazard from over-heated wires.
- Never unplug your refrigerator by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
- Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.
- When removing the refrigerator away from the wall, be careful not to roll over or damage the power cord.
- If supply power cord is damaged it should be replaced with original equipment manufacture parts. To avoid hazard this should be done by a qualified service technician.
USE OF ADAPTER PLUGS
- NEVER USE AN ADAPTER PLUG.
- Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
- The incoming power source to the cabinet including any adapters used must have the adequate power available and must be properly grounded.
- Only adapters listed with UL should be used.
- NORTH AMERICA USE ONLY NEMA plugs
- TRUE uses these types of plugs. If you do not have the right outlet have a certified electrician install the correct power source.
NOTE
International plug configurations vary by voltage and country.
INSTALLATION
OWNERSHIP
To ensure that your unit works properly from the first day, it must be
installed properly. We highly recommend a trained refrigeration mechanic and
electrician install your TRUE equipment. The cost of a professional
installation is money well spent.
Before you start to install your TRUE unit, carefully inspect it for freight
damage. If damage is discovered, immediately file a claim with the delivery
freight carrier.
TRUE is not responsible for damage incurred during shipment.
UNCRATING TOOLS REQUIRED
- Adjustable Wrench
- 1/2 inch socket (Castor Bolts)
- 3/4 inch socket (Skid Bolts)
- Level
- The following procedure is recommended for uncrating the unitl.
- Remove the outer packaging, (cardboard and bubbles or Styrofoam corners and clear plastic.
- Inspect for concealed damage.
- Again, immediately file a claim with the freight carrier if there is damage.
- Move your unit as close to the final location as possible before removing the wooden skid.
NOTE
KEYS FOR COOLERS WITH DOOR LOCKS ARE LOCATED IN WARRANTY PACKETS.
LOCK AND KEYS
The following procedure is for locking and unlock unit
- Insert the key and turn.
- Remove the key.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the ground prong from the power cord. For personal safety, this appliance must be properly grounded. The power cord of this appliance is equipped with a grounding plug which mates with a standard grounding wall outlet to minimize the possibility of electric shock hazard from this appliance. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. If the outlet is a standard 2 prong outlet, it is your personal responsibility and obligation to have it replaced with the properly grounded wall outlet. The unit should always be plugged into its own individual electrical circuit, which has a voltage rating that matches the rating plate. This provides the best performance and also prevents overloading building wiring circuits which could cause a fire hazard from overheated wires. Never unplug your unit by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet. Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end. When removing the unit away from the wall, be careful not to roll over or damage the power cord.
ELECTRIC INSTALLATION & SAFETY INFORMATION
- If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
- Lamps must be replaced by identical lamps only.
- Appliance tested according to the climate classes 5 and 7 temperature and relative humidity.
ELECTRICAL INSTRUCTIONS
- Before your new unit is connected to a power supply, check the incoming voltage with a voltmeter.
- If anything less than 100% of the rated voltage for operation is noted, correct immediately.
- All units are equipped with a service cord, and must be powered at proper operating voltage at all times.
- Refer to cabinet data plate for this voltage.
TRUE RECOMMENDS THAT A SOLE USE CIRCUIT BE DEDICATED FOR THE UNIT.
WARNING
Compressor warranties are void if compressor burns out due to low voltage.
Power supply cord ground should not be removed. Do not use electrical
appliances inside the food storage compartments of the appliances unless they
are of the type recommended by the manufacturer.
NOTE
To reference wiring diagram, remove front louvered grill, wiring diagram is
positioned on the inside cabinet wall.
WIRE GAUGE CHART
LOCATING
- Make sure unit is as close to the final location as possible.
- Remove the shipping bolts located at the bottom of the wooden skid.
- Carefully slide the unit off the wooden skid. Slide packing material underneath the side of the unit hanging off the skid.
- Then install castors or legs for that side of the unit.
- Then carefully slide the other side of the unit off one corner at a time while installing castors or legs for each corner.
- Use packing material for under each corner of the unit before installing a castor or leg.
Removing shipping bolts
LEVELING
Set unit in its final location. Be sure there is adequate ventilation in your room. Under extreme heat conditions, (100°F+, 38°C+), you may want to install an exhaust fan.
WARNING
WARRANTY IS VOID IF VENTILATION IS INSUFFICIENT
- Proper leveling of your TRUE cooler is critical to operating success for non-mobile models.
- Effective condensate removal and door operation will be effected by leveling.
- The cooler should be leveled front to back and side to side with a level.
- Ensure that the drain hose or hoses are positioned in the pan.
- Free plug and cord from inside the lower rear of the cooler do not plug in.
- The unit should be placed close enough to the electrical supply so that extension cords are never used.
- Appliance tested according to the climate classes 5 and 7 for temperature and relative humidity.
NOTE
If the cabinet has a center leveling screw, castor, or leg, make sure it is
adjusted properly so it makes full contact with the floor after the cabinet
has been leveled.
WARNING
CABINET WARRANTIES ARE VOID IF OEM POWER CORD IS TAMPERED WITH. TRUE WILL NOT
WARRANTY ANY UNITS THAT ARE CONNECTED TO AN EXTENSION CORD.
SEALING CABINET TO FLOOR
STEP 1
Position Cabinet – Allow one inch between the wall and rear of the refrigerator to assure proper ventilation. For freezers 3 inches between the wall and rear of the cabinet will assure proper ventilation.
STEP 2
Level Cabinet – Cabinet should be level, side to side and front to back. Place a carpenter’s level in the interior floor in four places.
- Position level in the inside floor of the unit near the doors.
- Level should be parallel to cabinet front.
- Level cabinet.
- Position level at the inside rear of cabinet.
- Again level should be placed parallel to cabinet back.
- Perform similar procedures to steps A & B by placing the level on inside floor left and right sides parallel to the depth of the cooler.
- Level cabinet.
STEP 3
Draw an outline on the base on the floor.
STEP 4
Raise and block the front side of the cabinet.
STEP 5
Apply a bead of “NSF Approved Sealant”, (see list below), to floor on half inch inside the outline drawn. The bead must be heavy enough to seal the entire cabinet surface when it is down on the sealant.
STEP 6
Raise and block the rear of the cabinet
STEP 7
Apply sealant on floor as outlined in Step 5 on other three sides.
STEP 8
Examine to see that cabinet is sealed to floor around entire perimeter.
NOTE
Asphalt floors are very susceptible to chemical attack. A layer of tape on the
floor prior to applying the sealant will protect the floor.
NSF APPROVED SEALANTS
- Minnesota Mining #ECU800 Caulk
- Minnesota Mining #ECU2185 Caulk
- Minnesota Mining #ECU1055 Bead
- Minnesota Mining #ECU1202 Bead
- Armstrong Cork – Rubber Caulk
- Products Research Co. #5000 Rubber Caulk
- G.E. Silicone Sealer
- Dow Corning Silicone Sealer
ROLL-IN & ROLL-THRU RAMP INSTALLATION
Once the cabinet is in its final location and level the roll-in ramp can be installed. The ramp has three slotted holes in back. These slotted holes slide over three thumb screws located in the front of the cabinet near the floor. Be sure the doors are closing smoothly and not binding up on the ramp. To adjust door sweeper gasket, loosen slotted thumbscrews. The gasket can then be moved up or down and side to side. The gasket should make some contact with the ramp when the door is closing. This can be checked by opening up the door 3-4 and allowing the door to close. This process may have to be done several times before securing the sweeper gasket bracket. Once gasket is properly adjusted, tighten slotted thumbscrews.
DOOR SWEEP GASKET ADJUSTMENT
Adjust door sweeper gasket, loosen slotted thumbscrews. The gasket can then be moved up or down and side to side. The gasket should make some contact with the ramp when the door is closing. This can be checked by opening up the door 3-4 and allowing the door to close. This process may have to be done several times before securing the sweeper gasket bracket. Once gasket is properly adjusted, tighten slotted thumbscrews.
SETUP
STANDARD ACCESSORIES
DOOR CONFIGURATION:
After installing, cabinet doors can be adjusted for alignment. The hinge on the door and hinge on the cabinet can be adjusted accordingly.
STEP 1
To remove door open at a 90˚ angle from the cabinet and lift door up and out from the cabinet hinges carefully avoiding rain shield. Rest the door in a safe area.
STEP 2
Remove gray plastic cover from hinge located on the cabinet.
Use a standard screw driver and pry out the gray cover. This exposes the three Phillips screws anchoring the hinge to the cabinet. Loosen these three screws but don’t remove them. Adjustment can be made slightly up/down and side to side.
STEP 3
The hinge on the cabinet door can also be adjusted. Remove cover from hinge located on the door. Pull on the cover directly out from the door.
This exposes the three Phillips screws anchoring the hinge to the door. Loosen these three screws but don’t remove them. The hinge can be moved side to side, up and down.
NOTE
WHEN TIGHTENING THE HINGES TO THE CABINET AND DOOR DO NOT APPLY PRESSURE TO
THE PHILLIPS SCREWS. CAREFULLY ANCHOR THEM WITHOUT APPLYING EXTREME AMOUNTS OF
PRESSURE.
STEP 4
To adjust the lock latch remove two Phillips screws and the latch can be put to the side for later reinstallation. The lock base that anchors the latch can be adjusted simply by loosening the two Phillips screws, but not removing them. Then the lock base can be moved side to side for adjustment. After adjustment is complete tighten the lock base and install the latch back into place.
OPERATION
STARTUP
- The compressor is ready to operate. Plug in the cooler.
- Temperature controls are factory-set to give refrigerators an approximate temperature of 35°F (1.6°C) and freezers an approximate temperature of -10°F (-23.3°C). Allow unit to function several hours, completely cooling cabinet before changing the control setting.
- Temperature Control Location and Settings.
- Temperature control type will vary upon model and age of cabinet.
- Mechanical control or electronic control without display:
- Inside cabinet
- Behind cabinet
- Behind front or rear access grill
- Electronic control with display:
- In countertop
- In top louvered panel
- In or behind bottom louvered grill See website for adjustments, sequence of operation, and more information.
- Excessive tampering with the control could lead to service difficulties.
- Should it ever become necessary to replace temperature control, be sure it is ordered from your TRUE dealer or recommended service agent.
- Good air flow in your TRUE unit is critical.
- Be careful to load product so that it neither presses against the back wall, nor comes within four inches of the evaporator housing.
- Refrigerated air off the coil must circulate down the back wall.
NOTE
If the unit is disconnected or shut off, wait five minutes before starting
again.
RECOMMENDATION
Before loading product we recommend you run your TRUE unit empty for two to
three days. This allows you to be sure electrical wiring and installation are
correct and no shipping damage has occurred. Remember, our factory warranty
does not cover product loss!
LIGHT SWITCH LOCATION:
Light switch location depends upon the model. Most instances the switch is located next to the temperature control.
ENERGY SAVER SWITCH
With the mark in the down position, this will indicate that the ENERGY SAVER FUNCTION is OFF and will activate the door/frame heaters. With the 0 mark in the down position, this will indicate that the ENERGY SAVER FUNCTION is ON and will deactivate the door/frame heaters.
DIGITAL TEMPERATURE DISPLAY
The digital temperature display can view ˚C or ˚F. To achieve this, there is a small plug that will need to be removed to achieve ˚C reading. See image 1 for temperature display location. If the plug is kept in the back of the digital display ˚F will be viewable. See images for reference. When temperature display is in ˚C mode place the plug in a safe place so it can be easily reinstalled for ˚F reading.
Rear of Rain shield
MECHANICAL TEMPERATURE CONTROLS
COIL SENSING
An evaporator coil sensing temperature control ensures that the evaporator coil will remain clear of frost and ice by not allowing the compressor to restart until the coil temperature is above the freezing temperature. This is considered an off cycle defrost.
AIR SENSING
An air sensing temperature control used in a freezer application will require a defrost cycle with heaters to ensure that the evaporator coil is kept clear of frost and ice.
MECHANICAL TEMPERATURE CONTROL GENERAL SEQUENCE OF OPERATION
- Cabinet is plugged in.
- Interior lights will illuminate on Glass Door Models only. If lights do not come on verify the light switch is in the “ON” position. Solid door cabinets may or may not have lights that may be controlled by the door switch.
- The compressor and evaporator fans will start if the temperature control is calling for cooling.
- If the compressor does not start, verify that the temperature control is not in the OFF or 0 position.
- The temperature control may cycle the compressor and evaporator fan(s) on and off together.
- The temperature control is sensing the evaporator coil temperature.
- The temperature control should be set on the #4 or #5.
- The warmest setting is #1, the coldest is #9, and #0 is the off position.
- The thermometer is designed to read and display a cabinet temperature not a product temperature.
- The thermometer may reflect the refrigeration cycle swings of up and down temperatures.
- The most accurate temperature on a cabinet’s operation is to verify the product temperature.
- There is not a defrost timer as the temperature control will initiate the off-cycle defrost during each refrigeration cycle.
- At this time, the compressor will and the evaporator fan(s) may turn off.
- Defrost heaters are not installed on refrigerators and therefore will not be energized.
- After the evaporator coil temperature has been reached, as determined by the temperature control, the compressor will restart.
- There may be a timer located on the condensing unit base.
- This timer is not used for a defrost event.
- The timer will change the rotation of the reversing condenser fan motor.
- The compressor only will start if the temperature control is calling for cooling.
- If the compressor does not start, verify that the temperature control is not in the OFF or 0 position or the cabinet is not in a defrost event.)
- The evaporator fan(s) will remain off until a specific temperature of the evaporator coil is reached.
- The temperature control may cycle the compressor and evaporator fan(s) on and off together.
- The temperature control is sensing the air temperature.
- The temperature control should be set on the #4 or #5.
- The warmest setting is #1, the coldest is #9, and #0 is the off position.
- The thermometer is designed to read and display a cabinet temperature not a product temperature.
- The thermometer may reflect the refrigeration cycle swings of up and down temperatures.
- The most accurate temperature on a cabinet’s operation is to verify the product temperature.
- The defrost timer will initiate defrost during specific times of day.
- At this time, the compressor and evaporator fan(s) will turn off and the evaporator coil heater and drain tube heater will be energized.
- Some cabinets may also change the rotation of the reversing condenser fan motor.
- After the predetermined evaporator coil temperature has been reached or duration for defrost has expired, the compressor will restart and the evaporator fans will remain off until a specific temperature of the evaporator coil is reached.
WHEN TO MAKE AN ADJUSTMENT TO A MECHANICAL TEMPERATURE CONTROL
We advise to make a mechanical temperature control adjustment only for a high altitude location.
OPERATION INSTRUCTIONS REQUIRED TOOLS
Scale Guide for Measuring
Back of Temperature Control
Jewelers Screw Driver Small Screw Driver.
GE CONTROL INSTRUCTIONS
To adjust the temperature control take the control knob off to view the cut-in screw. The scale to the right may be used as a guide for measuring degrees of rotation required for altitude correction. The arrows indicate direction of screw rotation. Turn calibration screw clockwise to obtain warmer operating temperatures.
NOTE
Each 1/4 turn of the calibration screw is equal to approximately 2 degrees F.
Do not make more than 3/4 turn. After making adjustment, measure temperature
during three cycles before adjusting again. Only adjust the screw small
flathead on the face of the control next to the cam. Follow the Altitude
Correction Table to the right.
INSTALLATION INSTRUCTIONS
DANFOSS TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE APPLICATIONS:
REQUIRED TOOLS
- Allen Wrench (5/64)
- Torx Screw (T-7)
TERMS
- Cut out Temperature sensed by the controller that shuts the compressor off.
- Cut in Temperature sensed by the controller that turns the compressor on.
Bottom of Temperature Control
INSTRUCTIONS
DANFOSS TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE APPLICATIONS
STEP 1
Unplug cooler.
STEP 2
Remove the screws that secure the temperature control to the inset box.
STEP 3
To make these adjustments it may be necessary to remove the temperature control from the housing.
NOTE
You may have to remove the wires attached to the control. Take note as to
which wire is on which spade terminal.
STEP 4
Pull out gently from cabinet. Mechanical temperature controllers are affected when functioning at high altitude. The cut-in and cut-out temperatures will be colder than when the controller functions closer to sea level.
STEP 5
For high elevation installations, it may be necessary to warm-up the set points. To make the adjustment, insert the appropriate tool in each adjustment screw and turn 1/4 of a revolution clockwise to the right. This procedure will adjust both the cut-in and cut-out about 2˚F warmer.
STEP 6
Make sure to reconnect the wires to the proper spade terminal when reinstalling.
INSTALLATION INSTRUCTIONS TEMPERATURE CONTROL ALTITUDE ADJUSTMENT:
REQUIRED TOOLS
- Allen Wrench (5/64)
- Torx Screw (T-7)
INSTRUCTIONS
CUTLER HAMMER TEMPERATURE CONTROL ALTITUDE ADJUSTMENT
STEP 1
Unplug cooler.
STEP 2
Turn the temperature control to the “9” position.
STEP 3
Remove the screws that secure the mounting plate to the evaporator top. See Figure 2.
STEP 4
Pull control down gently from housing.
STEP 5
Turn screws counterclockwise (CCW).
STEP 6
Reassemble to cooler housing and return the temperature control to the 5 position.
DEFROST TIMER
DEFROST TIME CLOCK OPERATION FOR UNITS WITH MECHANICAL CONTROL
RECOMMENDED DEFROST SETTINGS:
TRUE Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario. All refrigeration equipment operating below 30°F will accumulate frost on the evaporator coil and will require routine defrost. Your TRUE equipment has been designed for three defrost periods. If you decide to deviate from these defrost time settings please follow the procedures for adjustment below.
TOOLS REQUIRED
- Phillips Head Screwdriver
- 1/4 Nut Driver or Socket
SETTING THE TIMER:
UNPLUG UNIT FROM POWER SUPPLY! DO NOT SET THE TIME BY ROTATING THE OUTER DIAL. Turn the minute hand clockwise until the time of day on the outer dial is aligned with the triangle marker on the inner dial (two o’clock position).
ADJUSTING THE DEFROST TIMER
Your TRUE freezer contains a defrost system that is temperature terminated, however the time clock has been designed with a time termination back-up so that the defrost period will not exceed thirty minutes. While TRUE requires a minimum 3 defrost periods not to exceed 30 minutes the procedure on this page should be followed to customize your specific needs.
NOTICE
If timer is not set for a minimum of 3 defrost per day for 30 minutes each,
the coil may develop excessive frost. This may lead to system failure and
product loss, which is not covered under warranty. The following procedure may
be followed to customize your needs. High usage, high temperature, and high
humidity may require 4 defrost settings per day. Always follow the
manufacturer’s recommended settings when programming the amount and duration
of the defrost cycles.
STEP 1
The white tabs located on the outmost area of the time clock have been factory set. Each tab represents 15 minutes of defrost time. Notice that at each defrost time two white tabs are set for 15 minutes each for a total of 30 minutes of defrost.
STEP 2
In order to program the time to begin the defrost cycle, flip the white tabs out to set the defrost time. To eliminate a defrost time flip the white tabs back toward the center of the Defrost Timer.
STEP 3
TRUE recommends a 30 minute defrost cycle three times per day.
ELECTRONIC TEMPERATURE CONTROLS
- Thermostat
- Defrost
- Display probe is not installed and / or activated in all applications when t3 is not installed and / or activated, the display probe is t1.
ELECTRONIC CONTROL GENERAL SEQUENCE OF OPERATION
- Cabinet is plugged in.
- Display will illuminate.
- Interior light will illuminate on Glass Door Models only.
- Solid door cabinet lights are controlled by the door switch.
- After the LAE control preprogrammed time delay of up to 6 minutes, the compressor and evaporator fans will start if the control is calling for cooling.
- Control or condenser fans may be already pre-programmed from the factory so at the start of every compressor cycle or during a defrost cycle, the condenser fan(s) will reverse for 30 seconds to blow dirt off the condensing coil.
- The LAE control will cycle the compressor but may also cycle evaporator fans on and off determined by the Set Point and Differential temperatures.
- The Set-Point is the adjustable preprogrammed temperature which shuts off the compressor and evaporator fan(s).
- This is not the programmed cabinet temperature.
- The Differential is the non adjustable preprogrammed temperature that is added to the Set-Point temperature that will restart the compressor and evaporator fan(s).
- The LAE control is designed to read and display a cabinet temperature not a product temperature.
- This cabinet temperature may reflect the refrigeration cycle of the Set-Point and its Differential, or it may show an average temperature.
- The most accurate temperature on a cabinets operation is to verify the product temperature.
- The LAE control may be preprogrammed to initiate defrost by interval or at specific times of day.
- At this time the dEF will appear on the display and compressor will turn off until a preprogrammed temperature or duration is reached.
- During this time for freezers only, evaporator fans will also turn off and the coil heater and drain tube heaters will also be energized. Some cabinets may also change the rotation of the reversing condenser fan motor.
- After the preprogrammed temperature or duration for defrost has been reached there may be a short delay for both the compressor and evaporator fans to restart. At this time dEF may still appear on the display for a short time.
HOW TO DIAGNOSE AN LAE ELECTRONIC CONTROL
Indicator lights for Refrigeration/Heating Mode, Fan Operation, Defrost Mode.
USING THE LAE ELECTRONIC CONTROL
LOCKING AND UNLOCKING THE LAE CONTROLLER WHY
Locking of control is necessary to prevent changes to program that may affect cabinet operation.
HOW TO LOCK AND UNLOCK LAE CONTROLLER
STEP 1
To change lock setting press and release the Info button t1 will appear.
STEP 2
Press the Down button until Loc appears.
STEP 3
While pressing and holding the Info button press the Up or Down button to
change the lock settings. If no appears, the controller is unlocked. If yes
appears, the controller is locked. See
images 3 and 4.
STEP 4
Once the lock setting has been set correctly release the info button . Wait 5 seconds for the display to show temperature.
HOW TO TURN OFF THE LAE ELECTRONIC CONTROL:
May need to unlock control.
WHY Turning off the control will deactivate all electrical components
CAUTION
Turning off the control will not shut off power to the cabinet. Cabinet must
be unplugged prior to any repair.
STEP 1
To turn off control, press and hold the Stand-by button until OFF appears. Release Stand-by button. See Image 2.
STEP 2
To turn on control, repeat prior steps and a temperature will appear.
TURNING THE GLASS DOOR MODEL LIGHTS ON AND OFF
May need to unlock control. WHY Light may be controlled by LAE Controller or interior light switch.
HOW TO TURN THE GLASS DOOR MODEL LIGHT ON AND OFF
STEP 1
To control interior / sign lights by the LAE Controller, press and release the Manual Activation button .
STEP 2
To control interior / sign lights by the interior door switch, depress the rocker switch to the “ON” position. Light switch is located on inside top right of the ceiling.
CHANGING THE SET POINT
May need to unlock control.
WHY
The set point is the temperature at which the compressor will shut off.
NOTE
The set point IS NOT the cabinet holding temperature.
HOW TO CHANGE THE SET POINT
STEP 1
To see the set point, press and hold the Info button.
STEP 2
While still holding the Info button , press the Up or Down button to change the set point.
STEP 3
Once the “set point” has been set correctly release the Info button . The display will show temperature.
INITIATE A MANUAL DEFROST
May need to unlock control.
WHY
A one time additional defrost may be necessary to clear accumulated frost / ice from evaporator coil.
HOW TO INITIATE A MANUAL DEFROST:
The method to initiate a manual defrost is determined by the Defrost Mode Parameter “DTM” preprogrammed in the controller.
REGULAR TIME DEFROST TIM
If controller is preprogrammed for TIM, press and release the Manual Defrost button until dEF appears.
REAL TIME CLOCK (RTC)
If controller is preprogrammed for “RTC” press the and hold the Manual Defrost button for 5 seconds until dh1 appears. Release the Manual Defrost button and then press and hold for an additional 5 seconds until dEF appears.
NOTE
Defrost will only terminate once a specific preset temperature or a preset
time duration is reached.
CHANGING DEFROST INTERVALS
May need to unlock control.
This can only be changed if defrost mode parameter DFM is set for TIM.
WHY
The defrost interval is the time duration between defrost cycles. The defrost
interval time starts when the cabinet is supplied power or after a manual
defrost.
HOW TO CHANGE DEFROST INTERVALS
STEP 1
To see the set point, press and hold the Info button and the Stand-by button at the same time.
NOTE
Depending on the version of control, one of three parameters will appear ScL
image 1a, SPL image 1b, MdL image 1c.
STEP 2
Push the Up button until dFt appears.
STEP 3
Press and hold the Info button to see the defrost interval time.
STEP 4
While pressing and holding the Info button , press the Up or Down button to change the defrost interval times higher the number the less frequent the cabinet will defrost.
STEP 5
Once the defrost interval time has been changed, release the Info button .
STE\P 6
Wait 30 seconds for the display to show temperature.
HOW TO CHANGE DISPLAY READOUT FROM FAHRENHEIT TO CELSIUS:
May need to unlock control. This can NOT be changed with the LAE model AR2-28 version of the control.
WHY
Changing readout will assist with customer application
STEP 1
To change the display, press and hold the Info button and the Stand-by button at the same time. MdL or SPL will appear.
STEP 2
Push the Down button until ScL appears.
STEP 3
Press and hold the Info button to see the readout scale.
STEP 4
While pressing and holding the Info button , press the up or down button to change the readout scale.
STEP 5
Once the “readout scale” has been changed, release the info button .
STEP 6
Wait 30 seconds for the display to show temperature.
DISPLAYING TEMPERATURE PROBES, T1, T2, T3
WHY: To display temperature probe readings in different locations of the cabinet.
HOW TO DISPLAY PROBE TEMPERATURES
STEP 1
To display T1 temperature, press and release the info button t1 will appear.
STEP 2
Press and hold the info button . This is the temperature of the T1 Probe.
STEP 3
By releasing the info button , t2 will appear. Press and hold the info button to display the temperature of the T2 probe.
STEP 4
By releasing the info button again, t3 will appear. Press and hold the info button to display the temperature of the T3 probe. If probe T3 is not activated, t3 will not appear of the display.
DISPLAY CODES
DISPLAY|
---|---
Defrost in progress| Room high temperature alarm
Controller in stand-by| Room low temperature alarm
Door open alarm| Probe T1 failure
Instant Probe 1 temperature| Probe T2 failure
Instant Probe 2 temperature| Probe T3 failure
Instant Probe 3 temperature| Maximum probe 1 temperature recorded
Minutes of the Real Time Clock| Minimum probe 1 temperature recorded
Hours of the Real Time Clock| Keypad state lock
LAE CONTROLLER PARAMETER SETTINGS FOR CELSIUS
For LAE control model AR2-28 ONLY, ALL parameters with a formula shown need to be converted for Celsius applications.
EXAMPLE
If current SPL is set for 20 degrees F the formula is (X-32) / 1.8 (20-32) /
1.8 = -6.7 Celsius.
AR2-28
SCL| 1C| | ADO|
SPL| X-32 / 1.8| AHM|
SPH| X-32/ 1.8| AHT| X-32 / 1.8
SP| X-32 / 1.8| ACC|
C-H| | IISM|
HYS| X / 1.8| IISL| X-32 / 1.8
CRT| | IISH| X-32 / 1.8
CT1| | IISP| X-32/ 1.8
CT2| | IIHY| X / 1.8
CSD| | IIFC|
DFM| | HDS|
DFT| | IIDF|
DH1| | SB|
DH2| | DS|
DH3| | DSM|
DH4| | DI2|
DH5| | STT|
DH6| | EDT|
DLI| X-32 / 1.8| LSM|
DTO| | OA1|
DTY| | OA2|
DPD| | CD|
DRN| | INP|
DDM| | OS1| (X) / 1.8
DDY| | T2|
FID| | OS2| (X) / 1.8
FDD| X-32) / 1.8| T3|
FTO| | OS3| X / 1.8
FCM| | TLD|
FDT| X / 1.8| TDS|
FDH| X/ 1.8| AVG|
FT1| | SIM|
FT2| | ADR|
FT3| |
ATM|
ALA| X32/ 1.8
AHA| X-32 / 1.8
ALR| X/ 1.8
AHR| X / 1.8
ATI|
ATD|
MAINTENANCE, CARE, CLEANING
CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be followed, including the following. Disconnect power to unit.
TOOLS REQUIRED
- Phillips Screwdriver
- Stiff Bristle Brush
- Adjustable Wrenc
- Air Tank or CO2 Tank
- Vacuum Cleaner
STEP 1
Disconnect power to unit.
STEP 2
Remove all screws securing top screen to unit.
STEP 3
Clean off accumulated dirt from the condenser coil and the fan with a stiff bristle brush. After brushing the components off vacuum all dirt residue from the coil, fan, and surrounding areas.
NOTE
If you cannot completely clean the condensing coil due to its position, then the front louvered panel will need to be removed.
Disconnect digital temperature control connections.
IMPORTANT WARRANTY INFORMATION
Condensers accumulate dirt and require cleaning every 30 days. Dirty
condensers result in compressor failure, product loss, and lost sales… which
are not covered by warranty. If you keep the Condenser clean you will minimize
your service expense and lower your electrical costs. The Condenser requires
scheduled cleaning every thirty days or as needed. Air is pulled through the
Condenser continuously, along with dust, lint, grease, etc. A dirty Condenser
can result in NON WARRANTEED part & Compressor Failures, Product Loss, and
Lost Sales. Proper cleaning involves removing dust from the Condenser. By
using a soft brush, or vacuuming the Condenser with a shop vac, or using CO2,
nitrogen, or pressurized air. If you cannot remove the dirt adequately, please
call your refrigera-tion service company. On the Spec Series units the
condenser is accessible on the top of the unit. You must lift open the cabinet
rain shield to expose the Condenser.
Spec Series models
The Condenser looks like a group of vertical fins. You need to be able to see through the condenser for the unit to function at maximum capacity. Do not place filter material in front of condensing coil. This material blocks air- flow to the coil similar to having a dirty coil.
THE CLEANING OF THE CONDENSER IS NOT COVERED BY THE WARRANTY
HOW TO CLEAN THE CONDENSER
- Disconnect the electrical power to the unit.
- Open the rain shield.
- Vacuum or brush the dirt, lint, or debris from the finned condenser coil.
- If you have a significant dirt build up you can blow out the condenser with compressed air.
CAUTION MUST BE USED TO AVOID EYE INJURY EYE PROTECTION IS RECOMMENDED
When finished be sure to close the rainshield. Reconnect the electrical power to the unit. If you have any questions, please call TRUE Manufacturing at 636-240-2400 or 800-325-6152 and ask for the Service Department. Direct to Service Department 1(855)372-1368.
STAINLESS STEEL EQUIPMENT CARE AND CLEANING
CAUTION
Do not use any steel wool, abrasive or chlorine based products to clean
stainless steel surfaces.
STAINLESS STEEL OPPONENTS
There are three basic things which can break down your stainless steel’s passivity layer and allow corrosion to rear its ugly head.
- Scratches from wire brushes, scrapers, and steel pads are just a few examples of items that can be abrasive to stainless steel’s surface.
- Deposits left on your stainless steel can leave spots. You may have hard or soft water depending on what part of the country you live in. Hard water can leave spots. Hard water that is heated can leave deposits if left to sit too long. These deposits can cause the passive layer to break down and rust your stainless steel. All deposits left from food prep or service should be removed as soon as possible.
- Chlorides are present in table salt, food, and water. Household and industrial cleaners are the worst type of chlorides to use.
RECOMMENDED CLEANERS FOR CERTAIN SITUATIONS / ENVIRONMENTS OF STAINLESS
STEEL
- Soap, ammonia and detergent medallion applied with a cloth or sponge can be used for routine cleaning.
- Arcal 20, Lac O Nu Eco shine applied provides barrier film for fingerprints and smears.
- Cameo, Talc, Zud First Impression is applied by rubbing in the direction of the polished lines for stubborn stains and discoloring.
- Easy-off and De Grease It oven aid are excellent for removals on all finishes for grease-fatty acids, blood and burnt-on foods.
- Any good commercial detergent can be applied with a sponge or cloth to remove grease and oil.
- Benefit, Super Sheen, Sheila Shine are good for restoration /passivation.
NOTE
The use of stainless steel cleaners or other such solvents is not recommended
on plastic parts. Warm soap and water will suffice.
8 STEPS THAT CAN HELP PREVENT RUST ON STAINLESS STEEL
USING THE CORRECT CLEANING TOOLS
Use non-abrasive tools when cleaning your stainless steel products. The stainless steel’s passive layer will not be harmed by soft cloths and plastic scouring pads. Step 2 tells you how to find the polishing marks.
CLEANING ALONG THE POLISH LINES
Polishing lines or “grain” are visible on some stainless steels. Always scrub parallel to visible lines on some stainless steels. Use a plastic scouring pad or soft cloth when you cannot see the grain.
USE ALKALINE, ALKALINE CHLORINATED OR NON-CHLORIDE CONTAINING CLEANERS
While many traditional cleaners are loaded with chlorides, the industry is providing an ever increasing choice of non-chloride cleaners. If you are not sure of your cleaner’s chloride content contact your cleaner supplier. If they tell you that your present cleaner contains chlorides, ask if they have an alternative. Avoid cleaners containing quaternary salts as they can attack stainless steel, causing pitting and rusting.
WATER TREATMENT
To reduce deposits, soften the hard water when possible. Installation of certain filters can remove corrosive and distasteful elements. Salts in a properly maintained water softener can be to your advantage. Contact a treatment specialist if you are not sure of the proper water treatment.
MAINTAINING THE CLEANLINESS OF YOUR FOOD EQUIPMENT
Use cleaners at the recommended strength (alkaline chlorinated or non- chloride). Avoid build-up of hard stains by cleaning frequently. When boiling water with your stainless steel equipment, the single most likely cause of damage is chlorides in the water. Heating any cleaners containing chlorides will have the same damaging effects.
RINSE
When using chlorinated cleaners you must rinse and wipe dry immediately. It is better to wipe standing cleaning agents and water as soon as possible. Allow the stainless steel equipment to air dry. Oxygen helps maintain the passivity film on stainless steel. HYDROCHLORIC ACID (MURIATIC ACID) SHOULD NEVER BE USED ON STAINLESS STEEL REGULARLY RESTORE/PASSIVATE STAINLESS STEEL.
GENERAL MAINTENANCE
LIGHT BULB REPLACEMENT (INTERIOR LIGHTS) GENERAL MAINTENANCE
WARNING
When replacing a light bulb make sure power to the unit is either turned off
or unplugged. Be careful when removing the light bulb. Please be aware of your
local ordinances in disposing old bulbs. These bulbs should be disposed in a
safe and correct manner. Simply unscrew the light bulb.
WARRANTY INFORMATION U.S.A. & CANADA ONLY
THIS WARRANTY ONLY APPLIES TO UNITS SHIPPED FROM TRUE’S MANUFACTURING FACILITIES. THREE-YEAR PARTS & LABOR WARRANTY TRUE warrants to the original purchaser of every new TRUE refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal and proper use and maintenance service as specified by TRUE and upon proper installation and start-up in accordance with the instruction packet supplied with each TRUE unit. TRUE’s obligation under this warranty is limited to a period of three (3) years from the date of original installation or 39 months after shipment date from TRUE, whichever occurs first. Any part covered under this warranty that are determined by TRUE to have been defective within three (3) years of original installation or thirty nine (39) months after shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies. The labor warranty shall include standard straight time labor charges only and reasonable travel time, as determined by TRUE. Warranty does not cover standard wear parts which include door gaskets, incandescent bulbs or fluorescent bulbs. Warranty also does not cover issues caused by improper installation or lack of basic preventative maintenance which includes regular cleaning of condenser coils.
ADDITIONAL TWO-YEAR COMPRESSOR WARRANTY
In addition to the Three (3) year warranty stated above, TRUE warrants its
hermetically and semi-hermetically sealed compressor to be free from defects
in both material and workmanship under normal and proper use and maintenance
service for a period of two (2) additional years from the date of original
installation but not to exceed five (5) years and three (3) months after
shipment from the manufacturer. Compressors determined by TRUE to have been
defective within this extended time period will, at TRUE’s option, be either
repaired or replaced with a compressor or compressor parts of similar design
and capacity. The two (2) year extended compressor warranty applies only to
hermetically and semi-hermetically sealed parts of the compressor and does not
apply to any other parts or components, including, but not limited to:
cabinet, paint finish, temperature control, refrigerant, metering device,
driers, motor starting equipment, fan assembly or any other electrical
component, etcetera 404A/134A/HYDROCARBON COMPRESSOR WARRANTY The two year
compressor warranty detailed above will be voided if the following procedure
is not carefully adhered to This system contains R404A, R134A, or R290
refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid
moisture absorbing qualities. If long exposure to the ambient conditions
occur, the lubricant must be removed and replaced with new. For oil amounts
and specifications please call TRUE technical service department
(855-372-1368). Failure to comply with
recommended lubricant specification will void the compressor warranty. Drier
replacement is very important and must be changed when a system is opened for
servicing. An OEM exact replacement should be used. The new drier must also be
the same capacity as the drier being replaced.3. Micron level vacuums must be
achieved to insure low moisture levels in the system. 500 microns or lower
must be obtained.
WARRANTY CLAIMS
All claims for labor or parts must be made directly through TRUE. All claims
should include: model number of the unit, the serial number of the cabinet,
proof of purchase, date of installation, and all pertinent information
supporting the existence of the alleged defect. In case of warranty
compressor, the compressor model tag must be returned to TRUE along with above
listed information. Any action or breach of these warranty provisions must be
commenced within one (1) year after that cause of action has occurred.WHAT IS
NOT COVERED BY
THIS WARRANTY
TRUE’s sole obligation under this warranty is limited to either repair or
replacement of parts, subject to the additional limitations below. This
warranty neither assumes nor authorizes any person to assume obligations other
than those expressly covered by this warranty. NO CONSEQUENTIAL DAMAGES. TRUE
IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING
FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF
REFRIGERATION FAILURE. WARRANTY IS NOT TRANSFERABLE. This warranty is not
assignable and applies only in favor of the original purchaser/user to whom
deliv-ered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN
MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IMPROPER USAGE. TRUE ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR
COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM IMPROPER USAGE OR
INSTALLATION OR FAILURE TO CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE
WARRANTY PACKET PROVIDED WITH THE UNIT. RELOCATION OF CABINET FOR REPAIR. True
is not responsible for the cost to move a cabinet for any reason from its
position of operation on the customer’s premises to make a warranty repair.
NON OEM PARTS. Use of non OEM parts without manufacturer’s approval will void
cabinet warranty. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING
TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. TRUE is not responsible for
the repair or replacement of any parts that TRUE determines have been
subjected after the date of manufacture to alteration, neglect, abuse, misuse,
accident, damage during transit or installation, fire, flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS. TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR
REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM INCORRECT SUPPLY
VOLTAGE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR UNSTABLE SUPPLY VOLTAGE.
NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE:
THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE
THREE (3) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL TWO (2) YEAR
COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN
LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND
BEYOND THE DESCRIPTION ON THE FACE HEREOF. OUTSIDE U.S. AND CANADA: This
warranty does not apply to, and TRUE is not responsible for, any warranty
claims made on products sold or used outside the United States and Canada.
This warranty only applies to units shipped from True’s manufacturing.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>