American Standard TWA07243A Odyssey with Symbio Heat Pumps Three Phase Instruction Manual
- June 9, 2024
- American Standard
Table of Contents
- American Standard TWA07243A Odyssey with Symbio Heat Pumps Three Phase
- Important Information
- Model Number Description — Heat Pump Condenser
- Single Compressor with Single Refrigerant Circuits
- Dual Compressors with Two Sets of Refrigerant Circuits
- TWA Accessories
- Controls
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
American Standard TWA07243A Odyssey with Symbio Heat Pumps Three Phase
Important Information
- Symbio™ controls (standard)
- Scroll compressor (TWA072-120A)
- Scroll compressors (TWA072-240D) with independent refrigerant circuits
- Single point power
- Compressor motor overload protection
- Compressor discharge temperature limit switch
- Control transformer
- High and low pressure cut-out switches
- Demand Defrost Control
- Internal pressure relief valves
- Electrical phase reversal protection
- Holding charge (Dry Nitrogen)
- Copper tube, aluminum plate fin coils
- Low ambient cooling to 50°F as shipped
- Low ambient cooling to 0°F with accessory head pressure control
- Mounting/lifting rails under base
- UL listed
- 5-year compressor warranty
- 1-year limited parts warranty
- Optional Extended Warranties
Model Number Description — Heat Pump Condenser
-
Digit 1–3 — Unit Function TWA = Split System Heat Pump
-
Digit 4–6 — Tonnage
072 = 6 Tons (60Hz)
090 = 7.5 Tons (60Hz)
120 = 10 Tons (60Hz)
180 = 15 Tons (60Hz)
240 = 20 Tons (60Hz) -
Digit 7 — Refrigerant
4 = R-410A -
Digit 8 — Voltage
3 = 208-230VAC – 3 PH (60Hz) 4 = 460VAC – 3 PH (60Hz)
W = 575VAC – 3 PH (60Hz)
K = 380VAC – 3 PH (60Hz) -
Digit 9 — Refrigeration Circuit/Stage
A = 1 Compressor/1 Line/1 Stage (Single) D = 2 Compressors/2 Line/2 Stage (Duals) -
Digit 10 — Major Design Sequence
A = Current Design Sequence -
Digit 11 — Minor Design Sequence
A = Current Design Sequence -
Digit 12–13 — Service Digits
-
Digit 14 — Efficiency Generation
B = Generation B -
Digit 15 — Controls
S = Symbio™ -
Digit 16 — None
0 = Not Used -
Digit 17 — Coil Protection
1 = Standard Coil w/ Hail Guard
3 = Black Epoxy Pre-Coated Condenser Coil with Hail
Guard (FIN/TUBE) -
Digit 18-20 — None
0 = Not Used -
Digit 21 — Communications Options
0 = No Option
1 = BACnet® BAS Communications
2 = LonTalk® Communications Interface (LCI) -
Digit 22-40 — None
0 = Not Used
Single Compressor with Single Refrigerant Circuits
LSH-1-A — TWA Split System Heat Pumps
R-410 Refrigerant
Dual Compressors with Two Sets of Refrigerant Circuits
LSH-1-B — TWA Split System Heat Pumps
R-410 RefrigerantSound
rating shown is tested in accordance with ARI Standard 270 or 370.
- Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
TWA Accessories
LSH-2-A
Model | Used With |
---|---|
Rubber Isolators | |
BAYISLT005* (black) | TWA072, TWA090, TWA120 |
BAYISLT009* (red) | TWA180 |
BAYISLT010* (green) | TWA240 |
Steel Spring Isolators | |
BAYISLT023* (red) | TWA072, TWA090, TWA120 |
BAYISLT024* (black) | TWA180 |
BAYISLT025* (yellow) | TWA240 |
Service Valve Kit | |
BAYVALV001* | TWA0724A, TWA1204A |
BAYVALV002* | TWA0904*A |
BAYVALV003* | TWA0724D, TWA0904D, TWA1204*D |
BAYVALV006* | TWA01804D, TWA2404D |
Low Ambient — On/Off Fan Control (External mount, small cabinets) 1 2
3
BAYLOAMS10 (External Mount, small cabinets)4| (all voltages) TWA072A,
TWA090A
BAYLOAMS20 (Internal mount, large cabinets)| (all voltages) TWA120, TWA180,
TWA240
Transducer Kit for Head Pressure Control (BAYLOAM335, 336, 435, 436, W36)
BAYLOTR0015| TWA072D, TWA090D, TWA120D
LonTalk Communications Interface 6|
BAYLTCI005*| All Models
- Cycles fan on/off (no modulating).
- When BAYLOAM is used, the Evaporator Defrost Control (EDC) must be disabled in the Symbio 700 controller configuration.
- Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures.
- BAYLOTR001 required when modulating BAYLOAMS10 kits used with units that have 2 compressors (dual circuit) and 1 condenser fan.
- BAYLOTR001 required when modulating BAYLOAM kits used with units that have 2 compressors (dual circuit) and 1 condenser fan.
- Field Installed LonTalk interface requires installation of Symbio control board with Advanced Diagnostic (not included).
Controls
LSH-2-B
Model Number | Description | Used With |
---|---|---|
BAYLTCI005* | LonTalk® Communication Interface (LCI) | TWA072-TWA240 |
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>