GOLDEN LIGHTING 9905-8P RBZ Cleo 8 Light 24 Inch Wide Waterfall Chandelier Instruction Manual

June 9, 2024
GOLDEN LIGHTING

GOLDEN-LIGHTING-LOGO

GOLDEN LIGHTING 9905-8P RBZ Cleo 8 Light 24 Inch Wide Waterfall

Chandelier

GOLDEN-LIGHTING 9905-8P-RBZ-Cleo-8-Light-24-Inch Wide -Waterfall-Chandelier-
PRODUCT-IMAGE

Thank You for Choosing Golden Lighting for Your Lighting Needs!

GOLDEN-LIGHTING 9905-8P-RBZ-Cleo-8-Light-24-Inch Wide -Waterfall-
Chandelier-01 Pendants & Linear Pendants Above a Kitchen Island

Center a linear pendant over the island. If hanging pendants, use one pendant for every 24″ of island. Fixtures should hang at least 30″ above the countertop.

We appreciate your business and hope you love your new light!

Great lighting can add value and enhance the look of your home. To ensure the best lighting in your space, remember to layer your lighting. This ensures that your space will have both task and ambient lighting. Coordinating fixtures like sconces, flush mounts, and pendants can help you meet your layered lighting needs and reinforce your desired aesthetic. Install the lights with dimmers that allow you to control the level of light output at any given moment.
Get function and style! Browse our site for coordinating lights and expert lighting advice. To help create the perfect look, visit www.GoldenLighting.com.

Love your light and want to show it off?
Follow us, share a picture, and tag us on Social…

How to Identify the Fixture’s Wires
GOLDEN-LIGHTING 9905-8P-RBZ-Cleo-8-Light-24-Inch Wide -Waterfall-
Chandelier-02

  • Hot: Smooth, Black, or Transparent with Black Inner Thread
  • Neutral: Ribbed, White or Transparent with White Inner Thread
  • Ground: Copper, Bare Metal, Green, or Transparent Inner Thread

GOLDEN-LIGHTING 9905-8P-RBZ-Cleo-8-Light-24-Inch Wide -Waterfall-
Chandelier-04Get help, quick tips, and explore curated content

Assembly Instructions: 9905-8P

For Customer Service, contact the place of purchase to arrange for replacement parts.

IMPORTANT:

  • All installation work should be done by accredited professional.
  • Shut off power supply at fuse or circuit breaker!
  • Use only the specified bulbs. Do not exceed the maximum wattage!
PREPARING FOR INSTALLATION

Carefully remove the new fixture from the carton as well as the yellow bag that holds all of the parts. See the important notes above. Shut off power
at the circuit breaker and remove old fixture from wall, including the old mounting strap. 1. From the parts bag remove the mounting strap assembly. One end of nipple (F) should be attached to mounting strap (A) with washer (D) and hex nut (C) in place. The other end should have canopy loop (H) attached. Attach mounting strap (A) to the junction box using mounting screws (B) and a screwdriver. Tighten securely. 2. Unscrew canopy loop collar (I) from canopy loop (H). Pass canopy (G) over the mounted canopy loop
to test the height. Approximately half of the canopy loop’s exterior threads should be exposed, and the canopy loop collar (I) should fit snugly onto the canopy loop (H). Remove canopy (G) and adjust the height of nipple (F) and canopy loop (H) until the desired height is reached.GOLDEN-LIGHTING 9905-8P-
RBZ-Cleo-8-Light-24-Inch Wide -Waterfall-Chandelier-03

ASSEMBLING THE FIXTURE
Feed the fixture’s wires up through the connector (R). Thread the top central column (P) to the connector (R). Carefully attached the small loop (M) of one end of the small chain (N) to the top loop (L) and the other end to the small ring (O) on the fixture ring (Q). 4. Measure to determine the correct number of chain links needed for proper hanging height. If necessary, use a pair of pliers to open and remove any excess chain. Attach one chain connector (K) to each end of the chain (J). Use one of the chain connectors (K) to attach one end of the chain (J) to the top loop (L) and close chain connector (K). Use the remaining chain connector (K) to attach the chain (J) to canopy loop (H). 5. Feed the fixture’s wires up through the chain (J) (every three links or so), pulling the wires until taut. Trim the wires to the desired length plus 8 to 10 inches. Gently slide canopy loop collar (I) and canopy (G) onto the chain/wires.

CONNECTING THE WIRES
Have an assistant support the fixture’s weight while completing the wiring. Refer to the wiring diagram and attach the fixture’s wires to the power supply wires from the junction box. Attach the fixture’s wires to the power supply wires from the junction box. Connect Hot to Hot (transparent wire with black inner thread, black, or smooth wire) Neutral to Neutral (transparent wire with white inner thread, white, or ribbed wire), and Ground to Ground (transparent wire with green inner thread, green wire, or copper). Twist the ends of the wire pairs together, and then twist on a wire connector. Make sure all twists are in the same direction. If there is no house ground wire coming from the junction box, locate ground screw (E) on the mounting bracket/mounting strap and wrap the fixture’s ground wire around the ground screw. Use a screwdriver to tighten the top of ground screw (E) onto the wires and into the mounting bracket/mounting strap. Tuck the wires into the junction box.

FINISHING THE INSTALLATION
Push canopy (G) up to the ceiling and slide canopy loop collar (I) up beneath the canopy. Tightly thread canopy loop collar (I) onto canopy loop (H) to secure canopy (G) in place. 8. Install light bulbs (not included) into sockets accordance with the fixture’s specifications. Do not exceed maximum recommended wattage. Your installation is now complete. Turn on the power and test the fixture.