Warning
-
This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings and in public buildings or buildings used by the public.
-
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of
the indications provided in the manuals / instruction sheets supplied with those products. -
Cut off the power supply before carrying out any maintenance procedures.
-
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
-
We advise against running the system wires through the same duct as the power cables (230V or higher). • To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system created using Comelit products has not been tampered with / damaged.
-
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for systems, by qualified technical personnel.
-
Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and warnings contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual / instruction sheet at any time and without prior notice.
-
The brands and commercial names appearing in this publication remain the property of their respective owners.
-
This product falls within the scope of European product directive 2012/19/UE concerning the management of waste electrical and electronic equipment (WEEE). The device should not be disposed of as
unsorted domestic waste as it consists of various materials which can be recycled at relevant premises. Contact your local authority to find out the location of the environmental companies best suited to receiving the product for disposal and subsequent proper recycling. The product is not potentially harmful to human health, as it does not contain toxic substances as specified in Directive 2011/65/EU (RoHS), but if abandoned in the natural environment may negatively impact the ecosystem. Read the instructions carefully before using the product for the first time. We advise against using the product for any purpose other than its intended use, as improper use may present the risk of electric shocks.
This symbol on the product label indicates that the product complies with the standards concerning waste electrical and electronic equipment. Improper use of the equipment, or abandoning it in the natural environment, may be punished by law.
Kit contents
The kit components are supplied pre-configured for operation. Further
information can be found in the full manuals, which are available to download
from the website pro.comelitgroup.com or by
unscrambling the following QR codes.
Installation notes
The camera must not be installed in front of light sources, or in places where
the filmed subject is against the light. In dim environments, we recommend
additional lighting is provided.
Art. AD2101
-
Brightness control
-
Colour intensity adjustment
-
Call volume adjustment (High/Medium/ Low)
-
L N mains power input 110-240 V~
-
Terminal protection
-
L1 L1 main bus line output (31 V )
-
L2 L2 riser bus line input (31 V )
A suitable omnipolar switch with a contact opening of at least 3mm must be
installed upstream of the video entry phone system.
- Disconnect the power supply before carrying out any operations on the wiring.
- Replace the protections on the terminals.
- Do not obstruct the ventilation and cooling slots or apertures.
Programming additional entrance panels
With switching device art. 1405, only one additional entrance panel may be installed. The two entrance panels must be programmed as main and secondary ; see table on page 9.
- The “Main entrance panel” ****carries out lock-release (or actuator) commands only when it is in call or self activation status.
- The “Secondary entrance panel” carries out lock-release (or actuator) commands whether it is in standby or in call or self activation status.
- If the system is in standby mode the first self activation command will activate the camera of the secondary entrance panel. Further commands switch between the two entrance panels, activating the main entrance panel and the secondary entrance panel alternately.
With switching device art. 1404, more than one additional entrance panel may
be installed. All the entrance panels must be programmed as shown in the table
on page 9. Please refer to the full manual, which is available to download
from the website pro.comelitgroup.com or by unscrambling the QR code.
√ Make a note of the DIPswitch settings
Programming
- Programming an entrance panel with switching device 1404.
- Programming a secondary entrance panel with switching device 1405.
- Programming a main entrance panel with switching device 1405
Operating distances
| A MAX| B MAX| C MAX
---|---|---|---
Comelit art. 4577 1 mm2(Ø 1,2 mm AWG 17) **DE
| 200 m (655 feet)| 100 m (330 feet)|
GEVEN UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24) EN!
| 100 m (330 feet)| 60 m (195 feet)|
0,28 mm2 (Ø 0,6 mm AWG 23) les : EURS
| 100 m (330 feet)| 60 m (195 feet)|
GURE ! 0,5 mm2 (Ø 0,8 mm AWG 20) -cable HE
| 100 m (330 feet)| 60 m (195 feet)|
THE 1 mm2 (Ø 1,2 mm AWG 17)
**| 100 m (330 feet)| 60 m (195 feet)| 30 m (98 feet)
1 mm2 (Ø 1,2 mm AWG 17)
| 80 m (260 feet)| 40 m (130 feet)|
1,5 mm2 (Ø 1,4 mm AWG 15)
| 100 m (330 feet)| 60 m (195 feet)| 50 m (164 feet)
UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24) MULTI PAIR CABLE|
200 m (660 feet)| 70 m (230 feet)|
UTP cable with multi-cable connection: FOLLOW THE COLOURS SHOWN IN THE DIAGRAM!
Basic diagram
- Max 20 m. Bedieningsknop lokale deuropener.
- Max 20 m. Bouton commande ouvre-porte local.
- Max 20 m. Local door-opener button.
Expansion with second entrance panel art. AD2101 and switching device art. 1405
For “Main entrance panel” and “Secondary entrance panel” programming, see page 8 Max 20 m. Local door-opener button.
CERTIFIED MANAGEMENT SYSTEMS
Documents / Resources
|
COMELIT KVA2101 Adam Mini Handset Audio or Video Kit Simplebus 2
System
[pdf] User Manual
KVA2101 Adam Mini Handset Audio or Video Kit Simplebus 2 System, KVA2101, Adam
Mini Handset Audio or Video Kit Simplebus 2 System
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>