TECHNICAL MANUAL
8” Touch module, Simplebus 1 and 2 for Ultra series
Warning
-
This Comelit product has been designed and manufactured for use in the creation of audio and video communication systems in residential, commercial, industrial and public buildings.
-
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the manuals / instruction sheets supplied with those products.
-
Disconnect the power supply before carrying out any operations on the wiring.
-
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
-
We advise against running the system wires through the same duct as power cables (230V or higher).
-
To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets; make sure the system created using Comelit products has not been tampered with / damaged.
-
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the Manuals / Instruction sheets. Any repairs must be carried out: for the products themselves, exclusively by Comelit Group S.p.A.; for the systems, by qualified technical personnel.
-
Comelit Group S.p.A. accepts no liability for any purpose other than the intended use, or failure to observe the indications and warnings contained in this manual / instruction sheet. Comelit Group S. p.A. reserves the right to change the information provided in this manual / instruction sheet at any time and without prior notice.
-
The manufacturer, Comelit Group S.p.A., hereby declares that the radio equipment art. 3455U complies with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at:
pro.comelitgroup.com/en-gb/product/3455U -
This product falls within the scope of European product directive 2012/19/UE concerning the management of waste electrical and electronic equipment (WEEE). The device should not be disposed of as unsorted domestic waste as it consists of various materials that can be recycled at relevant premises. Contact your local authority to find out the location of the environmental companies best suited to receiving the product for disposal and subsequent proper recycling. The product is not potentially harmful to human health, as it does not contain toxic substances as specified in Directive 2011/65/EU (RoHS), but if abandoned in the natural environment may negatively impact the ecosystem. Read the instructions carefully before using the product for the first time. We advise against using the product for any purpose other than its intended use, as improper use may present the risk of electric shocks.
This symbol on the product label indicates that the product complies with the standards concerning waste electrical and electronic equipment. Improper use of the equipment, or abandoning it in the natural environment, may be punished by law.
Compatibility table
Description
8” Touch Module for Simplebus 1 and Simplebus 2 systems, serial communication protocol UDB, complete with accessories for third-party entrance panel mounting.
Touch module
-
8″ touch screen
-
RFID reader
-
Connector for future uses
-
Earth cable
-
Jumper for future uses. Maintain default settings
-
Slot used to secure the terminal block for connection of the audio, audio/video module
-
Terminal blocks for connection
- D0 D1 GND Wiegand output
- IN Wiegand output command successful feedback
- V+ 33 VDC power supply positive for Simple key control unit
- D2+ D2- RS485 D2 for Simplekey control unit connection
- D1+ D1- RS485 D1 for Simplekey control unit connection
- GND 33 VDC power supply negative and common for RS485 D1, RS485 D2
- NO COM Touch module relay contacts
- NC
- IN GND Input for activation of the Touch module relay
-
MicroSD for configuration backup
-
Micro-USB for computer connection
B Adapter for MicroSD
C Cable for LAN connection (length 50 cm)
D Cable for connection to previous module (length 47.5 cm
E Terminal block -
Connector for connecting the previous/next module
-
JP1 for future uses, do not change the factory settings.
-
Connector for LAN connection
-
Pin for connection to 8” Touch module
-
V+ V- for future uses
CAUTION! With art. UT2020 UT2020B UT2020W UT2010 UT2010B UT2010W UT2010VC UT2010VCB UT2010VCW, J4 must be removed.
Technical specifications
COMPATIBLE SYSTEMS
- Simplebus 2 audio/video with power supply unit art. 4888C Yes
- Simplebus 2 audio/video with power supply unit art. 1210/1210A Yes
- Simplebus 2 audio with power supply unit art. 1210/1210A Yes
- Simplebus 1 audio Yes
- DISPLAY
- Display size 8”
- Type of display TFT
- Touch screen Yes, capacitive
- Resolution (pixel) 1280×720
- AUDIO SPECIFICATIONS
- Microphone MEMS digital audio sensor, omnidirectional
- Loudspeaker 28 mm (ø), 8 Ohm, 1 W (2)
- ELECTRICAL SPECIFICATIONS
- Absorption in standby 10.6 W
- Type of power supply External power supply
- Maximum absorption 11.6 W
- Power supply voltage 33 VDC
- HARDWARE SPECIFICATIONS
- Removable terminals Yes
- Communication port Micro-USB, 1 x Wiegand, 2 x RS485,
- Ethernet, Bluetooth 4.2
- Number of inputs 2
- Built-in proximity reader Mifare Classic RFID
- Backlighting colour White, Black
- Call type Digital
- Terminals RTE GND SE NO NC COM V- V+ L L //
- TX+ TX – RX+ RX- // D0 D1 IN GND //
- V+ D1+ D1- D2+ D2- GND // NO COM
- NC IN GND
- SETTINGS
- Loudspeaker volume Yes
- Backlighting brightness Yes
- Display backlighting Yes
- NETWORK AND COMMUNICATION PROTOCOLS
- LAN type Ethernet 10/100 Mbit/s
- IP address assignment DHCP, AUTO IP, static IP
- Wiegand Access codes: 26 bit max (4 bits for each digit, 2 parity bits, big endian). Comelit cards/keys: 34 bit max (32 bit payload,
- 2 parity bits, big endian), maximum distance of 150 m (cat. 5 UTP cable)
- ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS
- IK anti-vandal protection rating IK08
- IP protection rating IP54
- Environmental class IV
- Operating temperature -25 to 55
- Operating humidity (max. RH) 25 to 95
- CE certification RoHS II – 2011/65/EU (EN IEC
- 63000:2018), RED 2014/53/EU (EN
- 62311:2008, EN 62368-1:2014, EN
- 61000-6-1:2007, EN 61000-6-3:2007
- + A1:2011, ETSI EN 301 489-1 V2.2.0,
- ETSI EN 301 489-17 V3.2.0, ETSI EN 300 328 V2.1.1)
- MAIN FUNCTIONS
- Number of auxiliary relays 2
- Lock-release Yes
- Input for local key button Yes
- Input for door open indication Yes
- Access control via proximity reader Yes
- Access control via lock-release code Yes
- Number of lock-release codes 500
- System status visual indications Yes
- Customisable welcome message Yes
- No. of users that can be stored 500
- Number of proximity keys stored 500
- Date/time display Yes
- Customisable screensaver Yes
- Customisable button image Yes
- GENERAL DATA
- Product colour Black RAL9005
- Depth 48
- Height 212
- Width 155
- Coating material type ABS, Glass
- Product weight 1000
- PROGRAMMING MODE
- ViP Manager software Yes
Installing art. 3455U
- MEASUREMENTS FOR CREATING CUSTOM MONOLITH ENTRANCE PANELS
- The entrance panel plate should be 2.5 mm thick.
- The minimum distance from the hole for the audio or audio/video module and the hole for the Touch module is 51.25 mm. The maximum distance varies depending on the position of the audio or audio/video module on the plate. The length of cables C (50 cm) and D (47.5 cm) supplied
Use
Making direct calls
Calling the desired internal unit
Finding a name in the directory
Calling within a building
Scrolling through the directory
Searching for contacts in the directory
Using the access code
When the access code 00000 (5 digits by default) is entered, the touch screen is deactivated for 30 seconds to allow cleaning to take place
Programming
- To make full use of the available functions, ALL modules making up the external entrance panel must be updated to the latest firmware version, which is available to download from the website pro.comelitgroup.com.
Use ViP Manager software, available to download from the website pro.comelitgroup.com, to carry out the update.
There are 2 programming methods:
- Programming via Touch module. This can be used to perform basic configurations quickly and easily, for device startup: manage users (add, edit and delete user), select operating language, manage access codes… (see page 22)
- Programming via ViP Manager software (available to download free of charge from the website pro.comelitgroup.com). In addition to the basic configurations, this allows full and customised programming: change call layout, set a pre-saved or custom screensaver, activate RFID keys, set welcome message, customise buttons by adding images or company logos… (see page 23)
Programming via Touch module
To access the Settings menu:
- Press the lock-release button
- Press
- Enter the supercode (default: 778899)
NOTE: to guarantee security, we recommend changing the supercode.
SELECT LANGUAGE
Used to set the desired language
LAYOUT TYPE
Used to select the display type for the Touch module screen
- Name directory : show call buttons
- Direct call : show a keyboard used to call the user directly when the call address is known
- Call with Name Search : display allowing manual searching for user names
- Dual button direct.: show dual call buttons
SYSTEM TYPE
Used to select the call type:
- Standard (Simplebus) : in this mode, the user is identified by a name field and a call address field no longer than 3 digits (between 1 and 240).
- Example: Name = John Smith
- Call address = 2
- Indirect call: i n this mode the user is identified by a name field, a call address field and an indirect call code field no longer than 6 characters.
- Example: Name = John Smith
- Call address = 2 | Indirect call code = 100
- Simplekey synchronised: in this mode the user is identified as described in standard mode and the user directory is synchronised via the Simplekey module art. SK9020,
- Simplebus Top: in this mode, the user is identified by a name field, a Simplebus Top address field no longer than 3 digits (between 1 and 500) and a call address field of 3 digits (between 1 and 240).
- Example: Name = John Smith
- Simplebus Top address = 25
- Call address = 015
- SBC TOP indirect call: in this mode, the user is identified by a name field, a Simplebus Top address field no longer than 3 digits (between 1 and 500), a call address field of 3 digits (between 1 and 240) and an indirect code no longer than 6 characters.
- Example: Name = John Smith
- Simplebus Top address = 25
- Call address = 015
- Indirect call code = 100
- Simplekey synchronized Simplebus Top: in this mode the user is identified as described in Simplebus Top mode and the user directory is synchronised via the Simplekey module art. SK9020.
MANAGE USERS
Used to: add a user to the directory, edit/delete a user, delete the directory
Add user
For each contact, enter:
- name*
- second name
- description
- call address*
- Simplebus Top address* (Simplebus Top systems only)
- indirect call code* (only with indirect call type) add access code: enter the access code for the user you are configuring add RFID key: enter the RFID key code or pass it in front of the reader
- visible: make the button you are programming visible or not (default: visible)
Once configuration is complete, press and confirm you wish to save
Edit user
-
Press to edit the information for that contact
-
Press to delete the desired user
Once configuration is complete, press and confirm you wish to save -
Delete directory
- Press “Delete directory” to remove all saved contacts
-
MANAGE SUPERCODE
Used to edit the supercode ( default 778899) -
NOTE: the code must consist of at least 4 and no more than 6 characters
Once configuration is complete, press and confirm you wish to save
KEYBOARD
Used to customise the keyboard
- Set the keypad type by selecting one of the available options: Large buttons, QWERTY, AZERTY
- Set the keyboard format by selecting one of the following: Lower case, Upper case
RFID READER
-
Used to manage the RFID reader on the Touch module
-
Enable: enables RFID reader operation in standard mode
- the symbol turns red when the reader is enabled
- the symbol flashes in green when an authorised RFID key is read
- the symbol flashes in red when an unauthorised RFID key is read
-
Enable- RS485: enables operation in conjunction with access control unit art.
-
SK9020. the symbol turns red when the control unit is connected
- the symbol flashes in green when an authorised RFID key is read
- the symbol flashes in red when an unauthorised RFID key is read
-
For connection diagrams, please refer to the corresponding technical manual.
- Enab.-Wiegand: enables operation in conjunction with access control units which utilise Wiegand protocol. The maximum connection cable distance is 150 metres (UTP cable, CAT.5)
- Disable: disables reader operation
-
DISPLAY
- Used to customise the maximum and minimum screen brightness
-
DATE AND TIME
- Used to set the device date and time
-
NOTE : the date and time are only visible if enabled via ViP Manager
-
BLUETOOTH
- Used to connect the Touch module to a computer (see page 23).
-
RESET
- Used to restore the factory-set information
- At the end of the procedure the Touch module restarts
-
BACKUP/RESTORE
Used to force* backup of the device configurations for an up-to-date backup, and so that the configurations can be restored by loading an existing backup.
The micro-SD card provided can be used to save all the settings and logs for Touch module art. 3455U. This data is updated once a day.
CAUTION: the MicroSD must be inserted into the device for backup and restore procedures -
If the device is replaced, these settings can be copied to a new Touch module as follows:
- Remove the micro-SD card from the Touch module being replaced
- Insert it into the new Touch module
- Access the “Backup and restore” menu and restore the configuration.
INFORMATION
Used to view device information
Programming via ViP Manager
To view and program the entrance panel via ViP Manager:
- Download the software free of charge from the website pro.comelitgroup.com
- Connect the computer to the Touch module using one of the following methods:
- A Bluetooth
- Micro-USB
- C LAN
- Search for the device to configure as described on page 25
Connecting the computer via Bluetooth (wireless technology)
- √ The computer must have a Windows operating system.
- √ The computer must have Bluetooth enabled and must allow other
Bluetooth devices to be found.
-
1. Power the entrance panel as described in the table below![COMELIT-3455U-Touch-Module-Group- \(37\)](https://manuals.plus/wp-content/uploads/2024/03/COMELIT-3455U-Touch-Module-Group-37.png) ![COMELIT-3455U-Touch-Module-Group- \(38\)](https://manuals.plus/wp-content/uploads/2024/03/COMELIT-3455U-Touch-Module-Group-38.png) ![COMELIT-3455U-Touch-Module-Group- \(39\)](https://manuals.plus/wp-content/uploads/2024/03/COMELIT-3455U-Touch-Module-Group-39.png)
-
Press the lock-release button
-
Press
-
Enter the supercode (default: 778899)
-
Press “Bluetooth”
-
Press “Enable”
-
Press “Use ViP Manager”
-
Press “Pair computer”
-
Press “Scan” to start searching for available devices
-
Select the device you want to pair to start the pairing procedure
-
You will see the Touch module pairing request on your computer: follow the wizard to complete device connection
At the end of the procedure on the Touch module, the device is identified as “Connected” and “Authorised -
Press to return to the ViP Manager screen
-
Press repeatedly to return to the “Settings” screen
-
On your computer, open the Bluetooth Devices menu and select “Join a Personal Area Network
-
A window will appear on your computer: right-click on the “3455U_ XXXXXXXXXXXX” icon and select the following options: “Connect Via” / “Access Point
It is now possible to connect to the Touch module using ViP Manager software
Connecting the computer via Micro-USB
√ Before connecting the USB cable, power up the entrance panel
- Power the entrance panel as described in the table below
- Connect the PC to the Touch module using the USB cable
- Press the lock-release button
- Press
- Enter the supercode (default: 778899)
- Press “USB”
- Press “Enable network connection
Connecting the computer via LAN
Connect the entrance panel as shown in the table below
Searching for devices to configure
-
√ Connect the Touch module to the computer (see page 23 and 24) and open ViP Manager
In Options (1)/Local connections (2) select the correct network interface (3) in accordance with the method used to connect the computer and the touch module (Micro-USB, LAN, Bluetooth). Confirm by clicking OK (4). -
Click Scan system (5) to start searching for devices.
Entering names in the directory
-
Select Directories/Name directory
-
Enter the information required (at least one “Call address” and one
“Name” need to be filled out for each contact) -
Click “Write page” to send the data to the Touch module
Changing the call layout
- Select Layout/Settings
- Select the “Layout type” from the drop-down menu
- Click “Write page”to send the new configuration to the Touch module
If the selected layout is “name directory” and the number of users stored is between 1 and 6, the size of the call buttons will automatically adapt to the screen size
Restoring the micro-SD card configuration
The micro-SD card provided can be used to save all the settings and logs for
Touch module art. 3455U.
This data is updated once a day.
If the module is replaced, these settings can be copied to a new Touch module
as follows:
- Remove the micro-SD card from the Touch module being replaced
- Insert it into the computer using the special adapter provided
- Connect the new Touch module to the computer and connect to the latter using a USB/micro-USB cable and the ViP Manager software
- Search for the device to configure as described on page 25
- Use the mouse to right-click on the Touch module
- Select “Restore configuration”
- Select the restore file on the micro-SD card: backup/XX-XX-XX_bkp.tar.gz
- Remove the micro-SD card from the computer
For information concerning connection distances and system performance, please refer to the manuals for the audio and audio/video modules, which are also available online via the website pro.comelitgroup.com
art. 3455U – Simplebus2
Connection variant for module art. SK9020
-
- 20 m Max. Local lock-release button.
-
D2+ D2- Connection required for use of the RFID reader
- D1+ D1- Connection required for name syncing