Comelit Mini 2708W Door-Entry Phone with Handset Instruction Manual

June 5, 2024
Comelit

Mini 2708W Door-Entry Phone with Handset
Instruction Manual

TECHNICAL MANUAL

Mini 2708W/A Door-entry phone with the handset – Simplebus1

Warning

Intended use
This Comelit product has been designed and manufactured for use in the creation of audio and video communication systems in residential, commercial, industrial and public buildings.
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Wires
Disconnect the power supply before carrying out any operations on the wiring. Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual. We advise against running the system wires through the same duct as power cables (230V or higher).
Safe usage
To ensure Comelit products are used safely:

  • carefully observe the indications provided in the Manuals / Instruction sheets,
  • make sure the system created using Comelit products has not been tampered with / damaged.

Maintenance
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the Manuals / Instruction sheets. Any repairs must be carried out:

  • for the products themselves, exclusively by Comelit Group S.p.A.,
    for the systems, by qualified technical personnel.

Disclaimer
Comelit Group S.p.A. does not assume any responsibility for

  • any purpose other than the intended use,
  • failure to observe the indications and warnings contained in this Manual / Instruction sheet. Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction Sheet at any time and without prior notice.

Description

Miniseries door-entry phone with handset for Simplebus 1 audio systems. Equipped with a key button, a button for additional services such as calls to the porter switchboard…, call volume adjustment, Silent mode (Privacy) and floor call input. Correct positioning of the handset on the base is facilitated by invisible magnetized panels. The additional board art. 2735 is available to purchase separately, for an additional button with voltage-free contacts and call repetition.

  1. Lock-release button

  2. P1 button: Generic actuator/Switchboard call

  3. Additional button
    On card 2735, available to purchase separately.

  4. Loudspeaker

  5. Audio hook
    Do not press and hold the audio hook while the handset is lifted!

  6. Ringtone volume adjuster
    Top position = Ringtone at maximum volume Central position = Ringtone at medium volume Bottom position = Ringtone in silent mode (Privacy)

  7.  Red: silent mode enabled

  8. Remove the 2 elements only if the additional button onboard art. 2735 is being used.

  9. Connector for additional board art. 2735

  10. Terminal block M1 CFP CFP Floor door call input L L Bus line connection

  11. DIP-switch for setting user code (Paragraph “Programming” on page 6)

  12. JP1 jumper for selecting the Generic actuator or Switchboard call function of button P1
    A = Generic actuator
    C = Switchboard call

  13. 3-position ringtone volume selector

  14. Handset connector

Technical characteristics

GENERAL DATA

Product height (mm)
Product width (mm)
Product depth (mm)
Product weight (g)
Product colour
Material
Surface-mounted
Desk base-mounted| 190
103
28
300
White RAL9003
ABS
Yes
Yes, with specific accessory
---|---

COMPATIBLE SYSTEMS

Simplebus1 audio Yes

AUDIO SPECIFICATIONS

Microphone
Loudspeaker
Technologies implemented| 9.6 (ø) x 6.9mm, omnidirectional
50 mm (Ø), 50 Ohm, 0.25W
Full-Duplex
---|---

ELECTRICAL SPECIFICATIONS

Type of power supply
Power supply voltage
Maximum absorption (W)| Power supply via video entry bus
22 – 28 VDC
0.6
---|---

HARDWARE CHARACTERISTICS

Type of buttons
Service buttons
Terminals
A number of inputs (no.)| Mechanical
Lock-release
L L CFP CFP
1
---|---

SETTINGS

Ringtone volume Yes

ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS

Operating temperature (°C)
Operating humidity (max RH – %)
Environmental class
Conformity and Certifications| -5 to 40
25 to 75
III
RoHS II – 2011/65/EU (EN 50581:2012), EMC 2014/30/EU
(EN 61000-6-1:2007, EN 61000-6-3:2007+A1:2011)
---|---

MAIN FUNCTIONS

Lock-release
Actuator control
Switchboard call
Input for floor door call
Silent mode (Privacy)
Call repetition| Yes
Yes
Yes
Yes
Yes
Yes, with additional board art. 2735 (not included)
---|---

Installation

Connections

Connection to the door entry riser and the floor door call button

Where multiple door-entry phones have the same user code, connect the CFP button on one only; all the devices will ring simultaneously.
20 m MAX – Use shielded cable for the connection and do not route the cables in the vicinity of heavy inductive loads or power supply cables (230 V/400 V).

Programming

  • Each door-entry phone in the system is identified by means of its own code. This code must be set using the DIP switch on the phone card.
  • Refer to the Addressing table to identify the DIP-switch combination corresponding to the address you want to set.
  • Coding can take place at any time, even without a power supply.

Addressing table

  • NOTE: Code 240 is reserved for the porter switchboard
    System performance and layouts
    For further information of system performance and to view installation layouts, click on the system type that best meets your requirements:
    Simplebus1 Audio for the creation of audio systems for residential complexes
    CERTIFIED MANAGEMENT SYSTEMS

www.comelitgroup.com
Via Don Arrigoni, 5 – 24020
Rovetta (BG) – Italy
1 ed. 1rev. 12/2020 cod. 2G40002508

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals