COMELIT IPNVR004A08PB CCTV Manager Installation Guide

June 3, 2024
Comelit

IPNVR004A08PB CCTV Manager
Installation Guide
COMELIT IPNVR004A08PB CCTV Manager

Please read this manual thoroughly before use and keep it for future reference

Install and uninstall the software

Install the software
There are three setups:

  • MySQL-installer-community
  • Comelit CCTV Manager Server
  • Comelit CCTV manager client

Install MySQL
Double-click MySQL.exe to install.

  1. Select “I accept the license terms”, Click [Next], select “Custom” and then click [Next];COMELIT IPNVR004A08PB CCTV Manager - Fig 1
  2. Select MySQL Servers, unfold it, and select “MySQL Server 5.7”. Click to add it. Then click [Next] [Execute];COMELIT IPNVR004A08PB CCTV Manager - Fig 2
  3. Click [Next] [Next], as shown below.COMELIT IPNVR004A08PB CCTV Manager - Fig 3
  4. Check “TCP/IP”, “Open Firewall port for network access” and “Show Advanced Options” as shown below. Then enter MySQL Root Password (minimum of 4 characters.COMELIT IPNVR004A08PB CCTV Manager - Fig 4
  5. Click [Add User] to set a username and password. To avoid forgetting, please enter “root” and the password. Then click [OK] [Next];COMELIT IPNVR004A08PB CCTV Manager - Fig 5
  6. Click [Next] to go to the “Advanced Options” interface. Please set it according to the following picture. Then Click [Next];COMELIT IPNVR004A08PB CCTV Manager - Fig 6
  7. Click [Execute] [Finish]COMELIT IPNVR004A08PB CCTV Manager - Fig 7
  8. Click [Next] [Finish].COMELIT IPNVR004A08PB CCTV Manager - Fig 8

Install the Server

  1. Double click “Comelit CCTV manager server.exe”. Select the desired GUI language.COMELIT IPNVR004A08PB CCTV Manager - Fig 9 
  2. A tip will pop up to suggest you close the antivirus software.COMELIT IPNVR004A08PB CCTV Manager - Fig 10 
  3. Click “I accept the terms of the license agreement” and then click [Next].COMELIT IPNVR004A08PB CCTV Manager - Fig 11 
  4. Click [Browse] to select the installation location and then click [Next].COMELIT IPNVR004A08PB CCTV Manager - Fig 12
  5. Click [Next].COMELIT IPNVR004A08PB CCTV Manager - Fig 13 
  6. Check “Launch Software” as needed and then click [Finish]”.COMELIT IPNVR004A08PB CCTV Manager - Fig 14 

Install the Client

  1. Double click “Comelit CCTV manager Client setup.exe”. Select the desired GUI language.COMELIT IPNVR004A08PB CCTV Manager - Fig 15
  2. A tip will pop up to suggest you close the antivirus software.COMELIT IPNVR004A08PB CCTV Manager - Fig 16
  3. Click “I accept the terms of the license agreement” and then click [Next].COMELIT IPNVR004A08PB CCTV Manager - Fig 17 
  4. Click [Browse] to select the installation location and then click [Next].COMELIT IPNVR004A08PB CCTV Manager - Fig 18 
  5. Check “Launch Software” as needed and then click [Finish]”.COMELIT IPNVR004A08PB CCTV Manager - Fig 19 

Uninstall the Software
It is strongly recommended to back up the configuration data before installing the new version of the Comelit CCTV manager VMS. The uninstallation steps of the Server are similar to the uninstallation of the client.
Click “Start” All Programs Comelit CCTV manager Server Uninstall to pop up the following wizard. Click “Yes” to confirm.![COMELIT IPNVR004A08PB CCTV Manager

Then click the “Finish” button to completely uninstall the Authentication Server.COMELIT IPNVR004A08PB CCTV Manager - Fig 21

Login

Run Servers
Before logging onto the client, please ensure that all the servers are working normally. Having been installed successfully for the first time, the server tray will minimize on the taskbar of the computer. Double-click the server tray icon to pop up the server tray interface. You can also right-click the server tray icon and select “Display the main interface to pop up the server tray interface as shown below.COMELIT IPNVR004A08PB CCTV Manager - Fig
22

The working status and port can be checked from the server tray. All servers can be stopped and restarted. All server ports can be modified. Click the corresponding port number to modify it. The modified port will be saved automatically after you move your mouse to another place. The database can also be configured by clicking [Configure].

Login
Double-click the shortcut icon of “MonitorClient” to run the software as shown below.COMELIT IPNVR004A08PB CCTV Manager - Fig 24

  1. Enter your Username and Password (the default Username is admin; the default Password is admin).

  2. Enter the IP address and port (the default Port is 6003) of the authentication server.
    Check “Remember Password” or “Auto Login” as needed.

  3. Click [Login].

Via Don Arrigoni, 5
24020 Rovetta (BG) – Italy
www.comelitgroup.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>