TRIDONIC luxCONTROL BasicDIM ILD G2 Programmer Instruction Manual

June 9, 2024
TRIDONIC

**TRIDONIC lux CONTROL Basic DIM ILD G2 Programmer Instruction Manual

**

Operating the basic DIM ILD Programmer

Operating

NOTICE
Some functions of the basic DIM ILD Programmer can also be used with Tridonic sensors. A summary table can be found at other the end of this document under “Operating basic DIM ILD with other sensors

basic DIM ILD Programmer can be used to set parameters for the basic DIM ILD module. The following parameters are available:

Basic functions
Icon Designation Description
ON Switch luminaires on
Icon
OFF Increase current dimming leve
Dim up Decrease current dimming level
Icon
Dim down Change to automatic mode Dimming is started
Icon
Automatic mode Store the brightness level currently measured by the sensor as

target value for constant light
Icon| Set current light level| Store the brightness level currently measured by the sensor as target value for constant light control

Push to make switch functions

The abbreviation PTM stands for “push to make switch”.

Icon Designation Description
Icon
PTM Set ON PTM Set ON Enable storage of target level via push to make switch

input double clicking the push to make switch at the push to make switch input allows storing the brightness level currently measured by the sensor as target level for constant light control
| PTM Set OFF| Disable storage of target level via push to make switch input storing the target level via push to make switch input is not  possible

Constant light control settings

NOTICE
The light levels indicated are based on a standard room situation and may differ from the levels actually measured in the task area.

  • Try all three light levels and select the one most suitable!
Icon Designation Description
Light level low Set ambient light control to a level of approx. 150 lx
Light level middle Set ambient light control to a level of approx. 300 lx
Light level high Set ambient light control to a level of approx. 500 lx
Offset settings

Use the Offset settings to specify and define in detail differences in brightness between the two channels.

Icon Designation Description
Icon
Offset Value 0 % Set the difference in brightness between channel 2 and

channel 1 to 0 %
| Offset Value -30 %| Set the difference in brightness between channel 2 and channel 1 to -30 %
| Offset Value -50 %| Set the difference in brightness between channel 2 and channel 1 to -50 %
| Offset Mode Converging| Reduce the difference in brightness between channel 2 and channel 1 at increased or reduced dimming level. For example: at an offset value of -30 %, one channel’s dimming level is 30 % lower than the other’s (e.g
| Offset Mode Fixed| Maintain the difference in brightness between channel 2 and channel 1 at increased or reduced For example: at an offset value of -30 %, one channel’s dimming level is 30 % lower than the other’s (e.g. channel 2: 40 %; channel 1: 70 %). When dimmed up, channel 2 will remain at a level of 70 % as soon as channel 1 has reached the dimming level of 100 %.

Bright Out settings

The Bright Out function defines how the ambient light control system will respond to additional illumination by sunlight or other light

Icon Designation Description
Bright Out ON Switch on Bright Out: if the measured light level exceeds 150

% of the target level for more than 10 minutes, the light is switched off. If the measured light level falls below 100% of the target level, the PHASED light is switched back on again.

basicDIM ILD Programmer: Functions and Parameters | 12-2018 | en

Icon| Bright Out OFF| Switch off Bright Out: The light remains switched on at all times, irrespective of the light level measured.
---|---|---

Presence detection profile settings

The abbreviation P.I.R. stands for “passive infrared”. This function is used to control presence detection.

Icon Designation Description
Icon
P.I.R. inactive Disable presence detection Run-on time is automatically set

to “infinite”
| P.I.R. off only| Presence detection responds only to absence light must be switched on manually (push to make switch, remote control) if no persons are detected, light is switched off automatically Run-on time is au
| P.I.R. active| Enable presence detection light is switched on and off automatically based on the presence/absence of a person Run
Icon| Time delay 1min| 1 minute after the last presence was detected, light is dimmed to Sec. Level
| Time delay 10min| n-on time to 10 minutes 10 minutes after the last presence was detected, light is dimmed to Sec. Level
Icon| Time delay 20min| 20 minutes after the last presence was detected, light is dimmed to Sec. Level

basicDIM ILD Programmer: Functions and Parameters | 12-2018 | en

| If vacant 0min.| Set switch-off delay to 0 minutes light is switched off immediately after run-on time has expired
---|---|---
Icon| If vacant 1min.| Set switch-off delay to 1 minute light is switched off 1 minute after run-on time has expired
| If vacant 30min.| Set switch-off delay to 30 minute light is switched off 30 minutes after run-on tim has
| If vacant continuous| Set switch-off delay to “infinite” (neverOFF) light is not switched off after
| Sec. Level 1%| Set the absence level to 1 % = dimming level to which the light is dimmed after the run-on time has expired
| Sec. Level 10%| Set the absence level to 10 % = dimming level to which the light is dimmed after the run-on time has expired; applies only if “if vacant” 0min
Icon| Sec. Level 30%| Set the absence level to 30 % = dimming level to which the light is dimmed after the run-on time has expired; applies only if “if vacant” 0min
| Sec. Level 50%| Set the absence level to 50 % = dimming level to which the light is dimmed after the run-on time has expired; applies only if “if vacant” 0min

basicDIM ILD Programmer: Functions and Parameters | 12-2018 | en

Icon Designation Description
Icon
DALI Select DALI Broadcast as interface operating mode
DSI Select DSI as interface operating mode
Icon Designation Description
--- --- ---
Power Up ON luminaire is switched on again after a mains break
Power off luminaire is switched on again after a mains break

Operating basic DIM ILD with other sensors

Basic functions

Icon| Designation| DALI MSensor 02 / MSensor 5DPI 14| basicDIM DGC| SMART Sensor 5-10DPI 19f| DSI PTM
---|---|---|---|---|---
Icon| ON| | | |
Icon| OFF| | | |
Icon| Dim up| | | |
| Dim down| | | |
Icon| Automatic mode| | | |
Icon| Set current light level| | | |

Push to make switch functions

The abbreviation PTM stands for “push to make switch”

Icon| Designation| DALI MSensor 02 / MSensor 5DPI 14| basicDIM DGC| SMART Sensor 5-10DPI 19fe| DSI PTM
---|---|---|---|---|---
| PTM Set ON| | | |
| PTM Set OFF| | | |

Constant light control settings

Icon| Designation| DALI MSensor 02 /| basicDIM DGC| SMART Sensor 5-10DPI 19fe| DSI-SMART PTM
---|---|---|---|---|---
| Light level low| | | |
| Light level middle| | | |
| Light High|  | |  |

Offset settings

Icon| Designation| DALI MSensor 02 / MSensor 5DPI 14| basicDIM DGC| SMART Sensor 5-10DPI 19fe| DSI-SMART PTM
---|---|---|---|---|---
| Offset Value 0 %| | | |
| Offset Value -30 %| | | |
| Offset Value -50 %| | | |
| Offset Mode Converging| | | |
| Offset Mode Fixed| | | |

Bright Out settings

Icon| Designation| DALI MSensor 02 / MSensor 5DPI 14| basicDIM DGC| SMART Sensor 5-10DPI 19fe| PTM
---|---|---|---|---|---
Icon| Bright Out ON| | | |
Icon| Bright Out OFF| | |  |

Presence detection profile settings

Icon| Designation| DALI MSensor 02 / MSensor 5DPI 14| basicDIM DGC| SMART Sensor 5-10DPI 19fe| PTM
---|---|---|---|---|---
| P.I.R. inactive| | | |
| P.I.R. off only| | | |
| P.I.R. active| | | |
| Time delay 1min.| | | |
| Time delay 10min.| | | |
| 20min| | | |
| If vacant 0min| | | |
Icon| If vacant 1min.|  | |  |
---|---|---|---|---|---
| If vacant 30min.|  | |  |
| If vacant continuous| | | |
| Sec. Level 1%| | | |
| Sec. Level 10%| | | |
| Sec. Level 30%| | | |
Icon| Sec. Level 50%|  | |  |

Interface operating mode settings

Icon| Designation| DALI MSensor 02 / MSensor 5DPI 14| basicDIM DGC| SMART Sensor 5-10DPI 19fe| PTM
---|---|---|---|---|---
Icon| DALI| | | |
Icon| DSI| | | |

Return of power settings

Icon| Designation| DALI MSensor 02 / MSensor| basicDIM| SMART Sensor 5-10DPI 19fe| DSI-SMART PTM
---|---|---|---|---|---
Icon| Power Up ON| | | |
| Power Up OFF| | | |

TRIDONIC Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals