INSTALLATION

TRIDONIC 28002214 High-Frequency Motion Detector Smart Switch -
figTRIDONIC 28002214 High-
Frequency Motion Detector Smart Switch - fig1

Detection range

h 100 % 75 % 50 % 30 % 10 %

d

0,5 m| 5,0 m| 3,0 m| 1,5 m| 1,0 m| 0,50 m
1,0 m| 6,0 m| 4,0 m| 3,0 m| 2,0 m| 1,00 m
1,5 m| 6,5 m| 4,0 m| 3,0 m| 2,0 m| 1,00 m
2,0 m| 7,0 m| 4,5 m| 3,5 m| 2,5 m| 1,00 m
2,5 m| 7,0 m| 4,5 m| 3,5 m| 2,0 m| 1,50 m
3,0 m| 7,5 m| 5,5 m| 4,0 m| 1,5 m| 0,50 m
3,5 m| 5,5 m| 3,5 m| 2,0 m| 0,5 m| 0,25 m
4,0 m| 5,5 m| 3,0 m| 1,5 m| 0,5 m| 0,25 m
4,5 m| 3,5 m| 2,0 m| 1,0 m| 0,5 m| 0,25 m
5,0 m| 3,0 m| 1,5 m| 1,0 m| 0,5 m| 0,25 m

Motion detector for installation in luminaires.

Technical Data

Rated supply voltage 220 – 240 V
Mains frequency 50 Hz
Power consumption < 0.5 W
Frequency 5.8 GHz (± 75 MHz)
Transmission power < 0.2 mW
Load resistive 800 W
Load capacitive 400 VA
Detection angle 30 – 150°
Max. detection area at 3 m mounting height Max. mounting height ø = 7 m
Max. mounting height 5 m
Dimension L x W x H (28002214) 70 x 36.5 x 24.5 mm
Dimension L x W x H (28002235) 58 x 52 x 24.5 mm
tc temperature 85 °C
Ambient temperature ta -20 … +70 °C
Storage temperature ts -20 … +70 °C
Humidity min. 5 % … max. 85 % at 30 °C
Type of protection IP20
Protection class Class II
Casing material PC, halogen free
Casing colour RAL 9016 (white)

Installation

  • Not for use with phase cut dimmers
  • The sensor must protrude over the light sources
  • The power supply must be disconnected before installation
  • Suitable for installation only in indoor luminaires (e.g. corridors and closed parking garage) without vibrations
  • Opening angle of the sensor: must be at least 45 %
  • Motion detection: only possible when thin housing material is used (e.g. plastic or glass), do not use metal housing
  • Light sensor: must be able to detect reflected artificial light and reflected daylight
  • Reflected HF waves (e.g. of walls, floors, ceilings or furniture) from other transmitters affect motion detection

Setting up
Setting the detection area
The detection area can be restricted to prevent the lighting system being switched on unnecessarily, as would be the case if the area was too large. The detection area indicates the diameter within which motion is detected.

| 1| 2| 3| Sensitivity
---|---|---|---|---
I| ●| ●| ●| 100 % (default)
II| ○| ●| ●| 75%
III| ○| ●| ○| 50%
IV| ○| ○| ●| 30%
V| ○| ○| ○| 10%

Setting the switch-off delay
To prevent the lighting system being switched on and off unnecessarily you can set a switch-off delay. The delay starts after the last motion in the detection area. If a further  motion is detected in the detection area during this delay then the delay is retriggered. At the end of the delay the light will be switched off or the corridorFUNCTION is started.

| 4| 5| 6| Hold time
---|---|---|---|---
I| ●| ●| ●| 5 s (default)
II| ●| ○| ●| 30 s
III| ●| ○| ○| 1 min
IV| ○| ●| ●| 5 min
V| ○| ●| ○| 10 min
VI| ○| ○| ●| 20 min
VII| ○| ○| ○| 30 min

Setting the daylight threshold value
A threshold value can be set to prevent the lighting system from being switched on when there is already adequate illuminance. The threshold value indicates the illuminance  value below which detected motion causes the lighting system to be switched on.

| 7| 8| 9| Daylight sensor
---|---|---|---|---
I| ●| ●| ●| Disable (default)
II| ○| ●| ●| 50 Lux
III| ○| ●| ○| 20 Lux
IV| ○| ○| ●| 5 Lux
V| ○| ○| ○| 2 Lux

Note:
To ensure the sensor switches on in conjunction with the corridorFUNCTION you should set the threshold value to I = Disable. If the threshold value disabled the sensor will always switch on.

corridorFUNCTION
The corridorFUNCTION can be activated by applying a voltage of 230 V for 5 minutes at the switchDIM connection of the control gear or via corridorFUNCTION Plug.
Note: To apply a voltage of 230 V for 5 minutes at the switchDIM input of the control gear the sensor must detect motion for more than 5 minutes or a switch-off delay  longer than 5 minutes must be set.
Hereby, Tridonic declares that the radio equipment type smartSWITCH HF 5DP f is in compliance with Directive 2014/53/EU.
Hereby, Tridonic declares that the radio equipment type smartSWITCH HF 5DP f is in compliance with Directive UK SI 2017 No. 1206.
The full text is available at the following internet address:
https://trid.help/en28002214cer
https://trid.help/en28002235cer

Safety instructions

  • The device may only be used for the applications specified.
  • The relevant safety and accident prevention regulations must be observed.
  • The power supply must be switched off before handling the device.
  • Installation of this device may only be carried out by specialist staff who have provided proof of their skills.

04/22-15011865-7 We reserve the right to make technical changes without prior notice.
Tridonic GmbH & Co KG, www.tridonic.com, [email protected],
Tel. +43 5572 395-0

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TRIDONIC User Manuals

Related Manuals