EUROM 370874 Desset Air 10 Device Instruction Manual

June 4, 2024
EUROM

EUROM 370874 Desset Air 10 Device

EUROM 370874 Desset Air 10 Device-fig1

Performance chart

| Desset Air 10| Desset Air 20
---|---|---
Working range| 5 – 35°C| 5 – 35°C
Operating humidity| > 35%| > 35%
LO=low humidity= <35%, the device does not work

The device does not dehumidify at a temperature <5°C and / or an air humidity of <35%.

Thank you
Thank you very much for choosing for a EUROM device. You have made a good choice! We hope you will be satisfied about its functioning. To get maximum profit from your product, it is important to read this manual attentive and totally before use, and to understand what is written. Read especially the safety instructions: they are there to protect you and your environment. Keep the manual in a safe place for future reference. Store also the package: that is the best protection for your product in times of no-use. And if you at any time pass the appliance on, pass on the manual and package too. We wish you a lot of fun with the Desset Air !
Eurom
Kokosstraat 20
8281 JC Genemuiden (NL)
info@eurom.nl
www.eurom.nl
This manual has been complied with the utmost care. Nevertheless, we reserve the right to optimize this manual at any time and to adjust it technically. The image used may differ

Symbol Explanation

  • This appliance is filled with Propane gas R290. Follow stricktly the manufacturer’s instruction concerning use and repairs!
  • Before using the machine, carefully read this entire instruction manual.
  • Do not install, operate or store the device in a room smaller than 4m².
  • Do not cover!

Technical details

| Desset Air 10| Desset Air 20
---|---|---
Power supply| 220-240V~50 Hz| 220-240V~50Hz
Power consumption| 280 Watt| 380 Watt
Refrigerant| R290 / 45g| R290 / 85 g
Working range| 5 – 35°C| 5 – 35°C
Operating humidity| >35%| >35%
Water tank| 2.0 liter| 5.0 liter
Noise level| ≤ 42 dB(A)| ≤ 47 dB(A)
Humidistat| +| +
Timer| +| +
Size (WxDxH)| 19 x 27,5 x 48,5 cm| 24,5 x 28 x 51 cm
Weight| 9,5 kg| 11,5 kg

This appliance creates a dryer and more comfortable living environment by removing unwanted moisture from the air in the home or in the working environment. To do this, it makes use of cooling techniques. The lightweight appliance is fitted with swivelling wheels, so that it can be easily moved from room to room. The appliance uses little energy and only emits a minimum amount of noise.
Your Desset Air air dehumidifier’s hygrostat keeps the space at a pre-set humidity level. It is also fitted with a timer, which automatically turns the appliance on or off.

Cautions before use

  1. Read and retain these instructions for future reference!
  2. For indoor use only.
  3. Always keep the unit in vertical position. If the device is not stable and upright,, water from the tank can get into the interior of the device and damage something or cause a dangerous situation!
  4. Before moving, cleaning or perform maintenance on the unit, first switch off, then unplug and empty the water tank. Pull on the plug to remove from the socket, never pull on the cord.
  5. Leave the unit to stand for one hour before connecting to the mains supply after transport or when it has been tilted (max. 45°, e.g. during cleaning).
  6. Keep air-intake or output openings clean and unobstructed. Prevent foreign objects or fingers from entering the equipment via the venting or exhaust openings as this may lead to electric shock, fire or damage.
  7. The supply voltage and utility frequency, specified on the machine, need to match those of the socket that is used. The electrical installation needs to be protected by an earth leakage circuit breaker (max. 30 mA.). Only connect the equipment to an earthed socket!
  8. Fully extend the cord before plugging in. Do not run the cord underneath carpeting; do not cover it with mats, carpet strips, or similar and make sure it is not placed in any passageways. Make sure the cord cannot be stepped on and that no furniture is placed on top of it. Prevent that the cable gets hot. Do not lead the cord around sharp corners and do not roll it up too tightly after use!
  9. If the supply cord is damaged, it must be replaced by an approved service representative or a similar qualified person in order to avoid a hazard.
  10. Never use the plug to start and stop the unit. Always use switch on the control panel.
  11. Don’t use bug sprays or other flammable cleaners on the unit. Do not expose the device to the influence of chemicals.
  12. Never pour or spray water over the unit. Never immerse the appliance in water or place it in the immediate vicinity of water or taps etc.
  13. Never place the appliance in the vicinity of highly inflammable and/or hazardous substances.
  14. Do not stand or sit on the appliance, or put anything on it.
  15. Regularly remove the water that is collected in the reservoir in the prescribed manner.
  16. Do not use the appliance in small, closed spaces such as a toilet etc., this can cause a fire.
  17. Do not turn on the appliance if you have discovered damage to the appliance, cord or plug, if the appliance is malfunctioning, if it has been dropped or if there are signs of any other defect. Immediately disconnect the plug from the socket and return the complete product to the vendor or to a certified electrician for inspection and/or repair. Always ask for original parts.
  18. This appliance is not intended for use by persons (including children) with reduces physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with appliance.
  19. When the temperature is below 10 ° C and the humidity is relatively low, it is not necessary to dehumidify.
    IMPORTANT! The device will not work when the temperature is below 5°C. If the device is switched on at a low temperature, icing can form on the evaporator! The appliance (incl. cord and plug) may only be opened and/or repaired by properly authorized and qualified persons.

Safety in relation to coolant R290

  1. This device contains the coolant R290. R290 is a coolant that complies with the relevant European Directives. Never perforate the coolant circuit. R290 is flammable (GWP 3)!
  2. Never use substances other than those recommended by the manufacturer for the defrosting process.
  3. This device must be used and stored in a room that does not contain sources of ignition, such as open flames or gas and electrical devices in operation.
  4. Do not perforate any of the components of the cooling circuit and do not set light to the device
  5. If the device is installed, working or stored in an un-ventilated you must take measures to prevent fire or explosions caused by leaked coolant. Ensure that there are absolutely no sources of ignition (such as fire, heaters, sparking electrical equipment, lit cigarettes, etc.) in the same room!
  6. The device must be stored in such a way that mechanical defects are prevented.
  7. Do not install, operate or store the device in a room smaller than 4m².
  8. R290 is odourless, which means that you cannot smell leaks!
  9. Persons working on the cooling circuit must be in possession of the correct qualifications that state the person in question is competent to use coolant in accordance with a special evaluation that is recognised by the sector association.
  10. The repairs must be executed on the grounds of the recommendations of the manufacturer of the device. Maintenance and repairs that require the assistance of other qualified persons must be executed under supervision of someone who is specialised in the use of flammable coolant.

Description

  1. Front panel
  2. Air outlet
  3. Handle
  4. Control panel
  5. Filter
  6. Back panel
  7. Water tank
  8.  Rubber feet (Desset Air 10) Castors (Desset Air 20)
  9. Electric cable

This product is a dehumidifier. It controls relative humidity by passing the air through the unit, forcing the excess moisture to condensate over the cooling elements (evaporator). Contact with this cold surface causes the moisture in the air to condense. This condensed water then drains safely into the water tank. The dried air then passes through the condenser where it is slightly warmed and re-enters the room at a slightly elevated temperature. Your health and possessions thrive best in a humidity between 45% and 65%.

Position
Excess moisture will travel throughout your home, in the same way that cooking smells waft to every room in the house. For this reason, the dehumidifier should be positioned, so that it can draw this moist air towards it from all over the home. Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier close to this area and later moving it to a more central point. When positioning the dehumidifier, ensure that it is placed on a level surface and that there is a minimum of 20 cm (8″) of space on either side of the unit to allow for efficient airflow. If you move the unit, it should first be switched off and the water tank emptied. We do not recommend the use of an extension lead, so please try to ensure that the unit is sufficiently close to a fixed mains socket. If it is necessary to use am extension lead, use one with earthing and please ensure the diameter of the wires of the cable is at least 1,5 mm². Don’t place the device near a heater, stove or other heat source, and not in full sunshine. When the dehumidifier is in operation, outside doors and windows should be closed when necessary for most efficient use. However, do not use the device in a sealed or very small space.

Operating

Control panel Desset Air 10
On/Off button

  • A. Timer button
  • B. Fan speed button
  • C. Air humidity higher button
  • D. Air humidity lower button
  • E. Clean dryer button
  1. Power lamp
  2. Timer lamp
  3. “Water reservoir full” lamp
  4. “Fan low” lamp
  5. “Fan high” lamp
  6. “Clean dryer” lamp
  7. Compressor lamp

Control panel Desset Air 20:

  • A. On/Off button
  • B. Timer button
  • C. Fan speed button
  • D. Air humidity higher button
  • E. Air humidity lower button
  • F. Clean dryer button
  1. Power lamp
  2. Timer lamp
  3. “Water reservoir full” lamp
  4. “Fan low” lamp
  5. “Fan high” lamp
  6. “Clean dryer” lamp
  7. Compressor lamp

Display

  • The display normally shows the air humidity in the space.
  • If you set a required humidity, it will show the set air humidity for a few seconds.
  • If you set a switching on or off time with the timer, the display will show the set number of hour for a few seconds.
  • If the air humidity is less than 35%, it will show “LO” (low) and the device does not work. If the air humidity is higher than 95%, it will show “HI” (high).

Initial operation

  1. Insert the plug into an appropriate socket, in accordance with the specifications on the type plate. Only connect the appliance to an earthed socket!
  2. Press the ON/OFF button (A); you will hear the compressor and the fan start up (the “comp” lamp c.q. the “power” lamp will now light up continuously). The appliance will start working. The display will show the air humidity in the space. By pressing the ON/OFF button again, you will switch the appliance off.
  3. Using the “Higher” and “Lower” buttons (D&E), you can now set the required air humidity between 30% and 90% (at intervals of 5%). The display will show the set air humidity for a few seconds, afterwards the current air humidity will be shown. Once the required level has been reached (± 2%), the compressor will stop, the fan continues to run. The dehumidifier thus keeps the air in the room moving and is therefore able to feel the humidity and to catch on again in time. If the air humidity rises once more to more than 3% above the set value, the appliance will start again. The compressor has a time lag of at least 3 minutes protection time between stopping and starting. If you set the air humidity with the “Lower” button to “Co”, the appliance will operate continuously.
  4. Using the Timer button (B), you can set starting and stopping times for the appliance. To do this, press the Timer button (B); lamp (2) will light up. If you do this while the appliance is not in operation (but with the plug in the socket), you will set the starting time; if you do this while the appliance is in operation, you will set the stopping time. The number of hours set will appear on the display. Each time you press the “Timer” button, an hour will be added (setting from 1 to 24 hours). You can cancel the timer setting by setting the time to 0 (0 comes after 24). The time setting is “forgotten” when you switch the appliance off manually, but is kept in memory if the appliance stops because the reservoir is full or during the thawing process.
  5. Desset Air 20: Pressing the fan speed button changes the fan speed from high to low and back. The lamp indicates the operational capacity.
  6. Desset Air 20: Pressing the clean dryer button will continually dehumidify the appliance at a high fan speed.
  7. Make sure that you then remove the plug from the socket after use.

Drainage

While the water tank is full, the compressor will stop for self-protection and the water full indicator will turn on and A tone will sound 15 times to warn the user that the reservoir needs emptying. To do this, press the sides of the reservoir lightly with both hands, and pull it carefully and straight out of the appliance. After empting the water tank, place the water tank into space. Please note: in case, the water tank has not been positioned well, the water full indicator keeps burning. The equipment does not work.

Attention!

  • Do not remove the float from the reservoir. No full reservoir signal will then be given and water will be able to leak out of the tank.
  • If the reservoir is dirty, clean it with cold or lukewarm water. Don’t ever use volatile chemicals, scouring pads, gasoline,
    detergents, chemically treated clothes, or other cleansing solutions. This can damage the tank and cause leaks.

Continuous drainage

When the dehumidifier is operated at very high humidity levels, the water tank will require more frequent drainage. In this situation, it may be more convenient to set the unit up for continuous drainage with the following procedures:

  1. Pull out the water tank.
  2.  Connect an appropriate tube (garden hose or something like that) with a clamp on the drain pipe. Please note: the water tube is not supplied with the unit.
  3. Put the water tank back to its position and lead the tube through the opening for continuous drainage down into a drain or a big container. Please note: in case, the water tank has not been positioned well, the water full indicator will turn into red. The equipment does not work
  4. Ensure the water will always drain away freely and the tube will remain in right place. Note! In very cold weather conditions, precautions should be taken to prevent the water tube from freezing.

Thawing
If the appliance is operating at a low temperature, the evaporator can freeze. This will influence dehumidification. In that case the operation of the appliance will be automatically interrupted and it will start to thaw (the fan will continue turning). (Desset Air 10: the “defrost” lamp will light up, Desset Air 20 does not have a lamp, but does thaw automatically.

Protection of the compressor
If you have switched the appliance off (or if it has switched itself off), then it cannot be switched on again for 3 minutes, this is to protect the compressor.

Maintenance

Always unplug the unit from the mains before carrying out any maintenance or cleaning of the unit.

Cleaning the body
Use a soft cloth to wipe the unit clean. Don’t ever use volatile chemicals, gasoline, detergents, chemically treated clothes, or other cleansing solutions. These all could possibly hurt the cabinet.

Cleaning the filter

  • Extract the filter holder.
  • Use a vacuum cleaner or tap the filter lightly for easy cleaning. If the filter is particularly dirty, use warm water (max. 40°C) with a small amount of a mild detergent.
  • Make sure the filter is completely dry before replacing. Do not expose the filter to sunlight.
  • Never use the appliance without a filter!
    The appliance (incl. cord and plug) may only be opened and/or repaired by properly authorized and qualified persons.

Storage

If not use the unit for an extended period of time. Please:

  • Press the unit off, unplug and tidy AC cord.
  • Completely empty the water tank and wipe it clean.
  • Clean the filter.
  • Cover the unit and store it in a cool and dry place, where it will not receive direct sunlight.

Troubleshooting

The unit does not operate:

  • Is the unit plugged in?
  • Is the house electricity on?
  • Is the room temperature below 5°C or above 35°C? If so, then it is out of the working range of the unit.
  • Is the humidity at least 35%? Otherwise, the device will not work>
  • Check the water tank is positioned properly in the unit and it is not full.
  • Make sure the air inlet and outlet are not obstructed.

The unit is leaking:

  • Make sure the unit and the water tank are not damaged and don’t show cracks or deformations.
  • Is the machine is stable and perfectly horizontal?

The unit is too noisy:

  • Check whether the unit is sitting on a level, flat and solid surface.
  • Is the filter dusty, or contaminated?

Warm air from the air outlet is normal. The circulation of the refrigerant can also make some noise during start and stop.
For other problems, please contact your service facility. The appliance (incl. cord and plug) may only be opened and/or repaired by properly authorised and qualified persons.

Disposal

At its end of life, discard the device according to the local laws and regulations, or deliver the device to your supplier.

Attachments
The CE declaration can be found at the end of this manual.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals