VENTURE LIGHTING LED Linear Highbay with Battery Backup User Manual

June 3, 2024
VENTURE LIGHTING

LED Linear Highbay with Battery Backup

USER MANUAL

VENTURE LIGHTING’S LED LINEAR HIGHBAY WITH BATTERY BACKUP

Before You Begin
Read These Instructions Completely and Carefully

Upgrade Instructions

STEP 1: Disconnect power from the existing luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.

STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.

STEP 3: Choose one of the accepted mounting methods.

V-Hook and Chain Mounting (A)

– Install the chain into the provided V-Hook. Secure the other end of the chain to a structure.

– To ensure the fixture is secure, press close the U-bend on the V-hook and the S-hooks. Surface Mounting (B)

– Install the Surface Mount side supports with the hardware included in the surface mount installation kit. Pendant Mounting (C)

– Install the Pendant Mount wiring compartment with the hardware included in the pendant mount installation kit. NOTE: Pendant opening for a 3/8″ NPT fitting.

STEP 4: Make the necessary wiring connections as shown in the wiring diagram. (D)

NOTE: The wiring between the battery backup, fixture test switch, driver(s) and LED modules is already completed. There are two black input wires: the flagged black wire should be connected to continuous (or unswitched) input power. When power is interrupted on this wire, the fixture will enter battery backup mode. The unlabeled input wire should be connected to the switch or control that will turn the fixture on and off under normal circumstances.

NOTE: The polarity of the dimming connections is important to ensure the performance as desired.

NOTE: If not using the dimming functionality, DO NOT connect the Driver Dim+ (purple) to the Driver DIM- (pink). The fixture will not operate as desired.

STEP 5: Power can now be restored to the fixture.

800-451-2606 Fax: 800-451-2605 VentureLighting.com

(A) V-Hook and Chain Mounting

(B) Surface Mounting

(C) Pendant Mounting

(D) Wiring Diagram

Wire Guard Installation

  1. Slide the wire guard clips through the wire guard.
  2. Using the fasteners provided, secure the wire guard clips to the fixture.

800-451-2606 Fax: 800-451-2605 VentureLighting.com

WARNING

Risk of fire and electric shock

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards, read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance. Contact a qualified electrician for installation.
  • Venture Lighting’s LED Linear Highbay fixture installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. The product should be installed and operated by a qualified electrician or technician in accordance with relevant local codes. Do not alter any open holes in an enclosure of wiring or electrical components during kit installation. All wiring connections should be capped with UL listed wire connectors. The installer must determine that the supply voltage meets the fixture requirement.

CAUTION

  • Risk of burn. Disconnect power and allow fixture to cool before handling the fixture.
  • Suitable for use in damp and dry locations.
  • Use minimum 90°C supply connectors.

800-451-2606
7905 Cochran Rd., Suite 300 Glenwillow, Ohio 44139 USA E-mail: Venture_Lighting@Venture_Lighting.com
VentureLighting.com
© 2022 Venture Lighting International Venture Lighting is a registered trademark of Venture Lighting International.