Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- Built-in active PFC function
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming; Timer dimming
- Typical lifetime > 62000 hours
- 7 years warranty
Applications
- LED street lighting
- LED high-bay lighting
- Parking space lighting
- LED fishing lamp
- LED greenhouse lighting
- Type “HL” for use in Class I , Division 2 hazardous (Classified) location.
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
HLG-120H series is a 120W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-120H operates from 90- 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for-40°C – +80°C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-120H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
Type | IP Level | Function | Note |
---|---|---|---|
Blank | IP67 | Io and Vo fixed | In Stock |
A | IP65 | Io and Vo adjustable through built-in potentiometer | In Stock |
B | IP67 | 3 in 1 dimming function (1 ~1 0VDC, 1 0V PWM signal and resistance) |
In Stock
AB| IP65| Io and Vo adjustable through built-in potentiometer & 3 in 1 dimming
function (1 ~1 0Vdc, 1 0V PWM signal and resistance)| In Stock
D| IP67| Timer dimming function, contact MEAN WELL for details(safety
pending).| By request
SPECIFICATION
MODEL| HLG-120H-12 O| HLG-120H-15D| HLG-120H-20O| HLG-120H-24D| HLG-
120H-30 D| HLG-120H-36D| HLG-120H-42D| HLG-120H-48O| HLG-120H-54D
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 20V| 24V| 30V| 36V| 42V| 48V| 54V
CONSTANT CURRENT REGION Note.4| 6 -12V| 7.5 – 15V| 10 – 20V| 12 – 24V|
15- 30V| 18 – 36V| 21 ~ 42V| 24- 48V| 27 – 54V
RATED CURRENT| 10A| 8A| 6A| 5A| 4A| 3.4A| 2.9A| 2.5A| 2.3A
RATED POWER| 120W| 120W| 120W| 120W| 120W| 122.4W| 121.8W| 120W| 124.2W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p|
150mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| Adjustable for A/AB-Type only (via built-in
potentiometer)
10.8 ~ 13.5V| 13.5~17V| 17 – 22V| 22 – 27V| 27- 33V| 33-40V| 38 – 46V| 43-
53V| 49- 58V
CURRENT ADJ. RANGE| Adjustable for A/AB-Type only (via bu ilt-in
potentiometer)
5 – 10A| 4 – 8A| 3 – 6A| 2.5 – 5A| 2 ~4A| 1.7 – 3.4A| 1.4 – 2.9A| 1.2- 2.5A|
1.1 – 2.3A
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±
1.0%| ± 1.0%| ± 1.0%
LINE REGULATION| ±0.5%| ± 0.5%| ± 0.5%| ±0.5%| ± 0.5%| ± 0.5%| ± 0.5%| ±
0.5%| ± 0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
SETUP, RISE TIME Note . 6| 1200ms,50ms/115VAC
500ms,50ms/230VAC
HOLD UP TIME (Typ.)| 12ms / 115VAC,230VAC
INPUT| VOLTAGE RANGE Note.5| 90- 305VAC 127 – 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47- 63Hz
POWER FACTOR (Typ . )| PF;;;:;0,98/115VAC, PF;;;:;0,95/230VAC,
PF;;;:; 0,93/277VAC@ full load
(Please refer to “POWER FACTOR (PF) CHARACTER ISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20% (@load;;;:;50% / 115VAC,230VAC; @ load ;;;:; 75% / 277VAC)
(Please refer to “TOTAL HARMON IC DISTORTION (THD)” section)
EFFICIENCY (Typ.)| 92%| 92%| 93%| 93%| 93%| 93%| 93%| 93.5%| 93.5%
AC CURRENT (Typ.)| 1.4A/115VAC 0.6A/ 230VAC 0.55A/277VAC
INRUSH CURRENT (Typ.)| COLD START 60A(twidth=3 75µs measured at 50%
Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| ****
5 units (circuit breaker of type B) / 9 un its (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA/ 277VAC
PROTECTION| OVER CURRENT| 95 – 108%
Constant current limiting, recovers automatically after fault condition is
removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 14-17V| 18-21V| 23 – 27V| 28 – 34V| 34- 38V| 41 -46V| 47-
53V| 54- 63V| 59- 65V
Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
ENVIRONMENT| WORKING TEMP.| Tease= -40- +80°C (Please refer to
“OUTPUT LOAD vs TEMPERATURE” sect ion)
MAX. CASE TEMP.| Tease= +80°C
WORKING HUMIDITY| 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40- +80°C, 10-95% RH
TEMP. COEFFICIENT| ±0 03%(C (0 – 60°C)
VIBRATION| 10-500Hz, 5G 12m in./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS Note. 8| UL8750 (type”HL”), CSA
C22.2 No. 250.0-08, BS EN/EN 61347-1 , BS EN/EN 61347-2-13, AS/NZS
61347-1(except for AB-type) ,
AS/NZS 61347-2-13 (except for AB-type) independent;GB19510.1,GB 19510.14, IP65 or IP67 , J61347-1, J61347-2-13 (except for B, AB and D-type),BIS IS15885( for 12B,24B,36A,54A only), EAC TP TC 004,KC6 1347-1,KC61347-2-13(except for D-type) approved
WITHSTAND VOLTAGE| I/P-O/P:3. 75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25″C/
70% RH
EMC EMISSION Note.8| Compliance to BS EN/EN55015, BS EN/EN55032
Class B, BS EN/EN61000-3-2 Class C (@ load;;;:; 50%) ; BS EN/EN61000-3-3,
GB17743 and GB17625.1, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN6
1547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV,
Line-Line 2KV),EAC TP TC 020
OTHERS| MTBF| 2185.8K hrs min. Telcordia SR-332 (Bellcore);
167.1Khrs min. MIL-HDBK-2 17F (25″C)
DIMENSION| 220′ 68′ 38.8mm (L’W’H)
PACKING| 1.12Kg; 12pcs/14.4Kg/0.8CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25″C of ambient temperature.
- Ripple & noise are measured at 20 MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Please refer to “DRIVING METHODS OF LED MODULE”.
- De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC ” sections for details.
- Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- This series meets the typical life expectancy of >62,000 hours of operation when Tease, particularly (tc) point (or TMP, per DLC), is about 75·c or less.
- Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
- The ambient temperature derating of 3.5″C/1OOOm with fanless models and of 5°C/1OOOm with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP waterproof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf