MEAN WELL HLG-120H-12 Series Constant Voltage Constant Current LED Driver Owner’s Manual

June 13, 2024
MEAN WELL

MEAN WELL HLG-120H-12 Series Constant Voltage Constant Current LED Driver

MEAN WELL HLG-120H-12 Series Constant Voltage Constant Current LED
Driver

Features

  • Constant Voltage + Constant Current mode output
  • Metal housing with class I design
  • Built-in active PFC function
  • IP67 / IP65 rating for indoor or outdoor installations
  • Function options: output adjustable via potentiometer; 3 in 1 dimming; Timer dimming
  • Typical lifetime > 62000 hours
  • 7 years warranty

Applications

  • LED street lighting
  • LED high-bay lighting
  • Parking space lighting
  • LED fishing lamp
  • LED greenhouse lighting
  • Type “HL” for use in Class I , Division 2 hazardous (Classified) location.

GTIN CODE

Description

HLG-120H series is a 120W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-120H operates from 90- 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for-40°C – +80°C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-120H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.

Model Encoding

Model Encoding

Type IP Level Function Note
Blank IP67 Io and Vo fixed In Stock
A IP65 Io and Vo adjustable through built-in potentiometer In Stock
B IP67 3 in 1 dimming function (1 ~1 0VDC, 1 0V PWM signal and resistance)

In Stock
AB| IP65| Io and Vo adjustable through built-in potentiometer & 3 in 1 dimming function (1 ~1 0Vdc, 1 0V PWM signal and resistance)| In Stock
D| IP67| Timer dimming function, contact MEAN WELL for details(safety pending).| By request

SPECIFICATION

MODEL| HLG-120H-12 O| HLG-120H-15D| HLG-120H-20O| HLG-120H-24D| HLG- 120H-30 D| HLG-120H-36D| HLG-120H-42D| HLG-120H-48O| HLG-120H-54D
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 20V| 24V| 30V| 36V| 42V| 48V| 54V
CONSTANT CURRENT REGION Note.4| 6 -12V| 7.5 – 15V| 10 – 20V| 12 – 24V| 15- 30V| 18 – 36V| 21 ~ 42V| 24- 48V| 27 – 54V
RATED CURRENT| 10A| 8A| 6A| 5A| 4A| 3.4A| 2.9A| 2.5A| 2.3A
RATED POWER| 120W| 120W| 120W| 120W| 120W| 122.4W| 121.8W| 120W| 124.2W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| Adjustable for A/AB-Type only (via built-in potentiometer)
10.8 ~ 13.5V| 13.5~17V| 17 – 22V| 22 – 27V| 27- 33V| 33-40V| 38 – 46V| 43- 53V| 49- 58V
CURRENT ADJ. RANGE| Adjustable for A/AB-Type only (via bu ilt-in potentiometer)
5 – 10A| 4 – 8A| 3 – 6A| 2.5 – 5A| 2 ~4A| 1.7 – 3.4A| 1.4 – 2.9A| 1.2- 2.5A| 1.1 – 2.3A
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ± 1.0%| ± 1.0%| ± 1.0%
LINE REGULATION| ±0.5%| ± 0.5%| ± 0.5%| ±0.5%| ± 0.5%| ± 0.5%| ± 0.5%| ± 0.5%| ± 0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note . 6| 1200ms,50ms/115VAC 500ms,50ms/230VAC
HOLD UP TIME (Typ.)| 12ms / 115VAC,230VAC
INPUT| VOLTAGE RANGE Note.5| 90- 305VAC        127 – 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE| 47- 63Hz
POWER FACTOR (Typ . )| PF;;;:;0,98/115VAC, PF;;;:;0,95/230VAC, PF;;;:; 0,93/277VAC@ full load

(Please refer to “POWER FACTOR (PF) CHARACTER ISTIC” section)

TOTAL HARMONIC DISTORTION| THD< 20% (@load;;;:;50% / 115VAC,230VAC; @ load ;;;:; 75% / 277VAC)

(Please refer to “TOTAL HARMON IC DISTORTION (THD)” section)

EFFICIENCY (Typ.)| 92%| 92%| 93%| 93%| 93%| 93%| 93%| 93.5%| 93.5%
AC CURRENT (Typ.)| 1.4A/115VAC        0.6A/ 230VAC       0.55A/277VAC
INRUSH CURRENT (Typ.)| COLD START 60A(twidth=3 75µs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| ****

5 units (circuit breaker of type B) / 9 un its (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT| <0.75mA/ 277VAC
PROTECTION| OVER CURRENT| 95 – 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 14-17V| 18-21V| 23 – 27V| 28 – 34V| 34- 38V| 41 -46V| 47- 53V| 54- 63V| 59- 65V
Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| Tease= -40- +80°C (Please refer to “OUTPUT LOAD vs TEMPERATURE” sect ion)
MAX. CASE TEMP.| Tease= +80°C
WORKING HUMIDITY| 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40- +80°C, 10-95% RH
TEMP. COEFFICIENT| ±0 03%(C (0 – 60°C)
VIBRATION| 10-500Hz, 5G 12m in./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS Note. 8| UL8750 (type”HL”), CSA C22.2 No. 250.0-08, BS EN/EN 61347-1 , BS EN/EN 61347-2-13, AS/NZS 61347-1(except for AB-type) ,

AS/NZS 61347-2-13 (except for AB-type) independent;GB19510.1,GB 19510.14, IP65 or IP67 , J61347-1, J61347-2-13 (except for B, AB and D-type),BIS IS15885( for 12B,24B,36A,54A only), EAC TP TC 004,KC6 1347-1,KC61347-2-13(except for D-type) approved

WITHSTAND VOLTAGE| I/P-O/P:3. 75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25″C/ 70% RH
EMC EMISSION Note.8| Compliance to BS EN/EN55015, BS EN/EN55032 Class B, BS EN/EN61000-3-2 Class C (@ load;;;:; 50%) ; BS EN/EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN6 1547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV),EAC TP TC 020
OTHERS| MTBF| 2185.8K hrs min. Telcordia SR-332 (Bellcore); 167.1Khrs min.        MIL-HDBK-2 17F (25″C)
DIMENSION| 220′ 68′ 38.8mm (L’W’H)
PACKING| 1.12Kg; 12pcs/14.4Kg/0.8CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25″C of ambient temperature.
  2. Ripple & noise are measured at 20 MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Please refer to “DRIVING METHODS OF LED MODULE”.
  5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC ” sections for details.
  6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
  7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
  8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
  9. This series meets the typical life expectancy of >62,000 hours of operation when Tease, particularly (tc) point (or TMP, per DLC), is about 75·c or less.
  10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
  11. The ambient temperature derating of 3.5″C/1OOOm with fanless models and of 5°C/1OOOm with fan models for operating altitude higher than 2000m(6500ft).
  12.  For any application note and IP waterproof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf