MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED Driver Instruction Manual

June 8, 2024
MEAN WELL

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED

Driver

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver

Features

  • Metal housing design with functional Ground
  • Class l design
  • Constant Current mode output
  • Built-in active PFC function
  • No load/Standby power consumption <0.5W
  • IP67/ |P65 rating for indoor or outdoor installations
  • Function options: output adjustable via potentiometer;
  • 3 in 1 dimming (dim-to-off); Smart timer dimming; DALI;
  • Typical lifetime>50000 hours
  • 5 years warranty

Applications

  • LED street lighting
  • LED harbor lighting
  • LED bay lighting
  • LED greenhouse lighting
  • LED flood lighting
    Comply with class l application

Description

ELGT-150-C series is a 105~150W LED AC/DC class II driver featuring the constant current mode and high voltage output. ELGT-150-C operates from 100-305VAC and offers models with different rated current ranging between 700mA and 1400mA. Thanks to the high efficiency up to 92%, with the fanless design, the entire series is able to operate tor -40C~+90C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. ELGT-150-C is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.

Model Encoding

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 1

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver-1

SPECIFICATION

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver-2 MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver-3

BLOCK DIAGRAM

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 2

DRIVING METHODS OF LED MODULE
This series works in constant current mode to directly drive the LEDs.

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 3

This characteristic applies to Blank/A/B/AB/D2-Type,For DA-Type, the Constant Current area is 60%-100% Vo.

DIMMING OPERATION

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 4

  • DIM+for B/AB-Type
  • DA+for DA-Type
  • PROG+ for D2-Type
  • DIM-for B/AB-Type
  • DA-for DA-Type
  • PROG-for D2-Type

X3 in 1 dimming function (for B/AB.Type)
Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
0-10VDC, or 10V PWM signal or resistance.
Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
Dimming source current from power supply: 100uA (typ.)

Applying additive 0- 10VDC

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 5

Applying additive 10V PWM signal (frequency range 100Hz – 3KHz):

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 6

Applying additive resistance:

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 7

Note:

  1. Min. dimming level is about 8% and the output current is not defined when 0%< lout<8%.
  2. The output current could drop down to 0% when dimming input is about OkQ or OVdc, or 10V PWM signal with 0% duty cycle.

XDALI Interface (primary side; for DA-Type)

  • Apply DALI signal between DA+ and DA-.
  • DALI protocol comprises 16 groups and 64 addresses.
  • First step is fixed at 8% of output.

Smart timer dimming function (for D2-Type by User definition)

MEAN WELL Smart timer dimming primarly provides the adaptive proportion dimming profile for the output constant current level to perform up to 14
consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed,
please contact MEAN WELL for details.

Ex: D01-Type: the profile recommended for residential lighting

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 8

Set up for D01-Type in Smart timer dimming software program

| T1| T2| T3| T4
---|---|---|---|---
TIME| 06:00| 07:00| 11:00| —
LEVEL
| 100%| 70%| 50%| 70%

: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.

Example: If a residential lighting application adopts DO1-Type, when turning on the power supply at 6:00pm, for instance:

  1. The power supply will switch to the constant current level at 100% starting from 6:00pm.
  2. The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on.
  3. The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on.
  4. The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
    The constant current level remains till 8:00am, which is 14:00 after the pOwer supply turns on.

Ex: D02-Type: the profile recommended for street lighting

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 9

Set up for D02-Type in Smart timer dimming software program:

| T1| T2| T3| T4| T5
---|---|---|---|---|---
TIME| 01:00| 03:00| 8:00| 11:00| —
LEVEL
| 50%| 80%| 100%| 60%| 80%

IME matches Operating Iime in the diagram whereas LEVEL matches Dimming Level.

Example: lfa street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance:

  1. The power supply will switch to the constant current level at 50% starting from 5:00pm.
  2. The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on.
  3. The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on.
  4. The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on.
  5. The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The
    constant current level remains till 6:30am, which is 14:00 after the power supply turns on.

Ex: D03-Type: the profile recommended for tunnel lighting

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 10

Set up for D03-Type in Smart timer dimming software program:

| T1| T2| T3
---|---|---|---
TIME| 01:30| 11:00| —
LEVEL
| 70%| 100%| 70%

: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.

Example: ía tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance:

  1. The power supply will switch to the constant current level at 70% starting from 4:30pm.
  2. The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on.
  3. The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
    The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.

OUTPUT LOAD vs TEMPERATURE(NOTE 7.)

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 11

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 12

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 13

LIFE TIME

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 14

MECHANICAL SPECIFICATION

XBlank-Type

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 15

xB/DA/D2-Type

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 16

※ A-Type

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 17

※ AB-Type

MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver 18

MANUAL INSTALLATION

Please refer to : http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>