MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED Driver Instruction Manual
- June 8, 2024
- MEAN WELL
Table of Contents
MEAN WELL ELGT-150-C series 105-150W Class Ⅱ Constant Current Mode LED
Driver
Features
- Metal housing design with functional Ground
- Class l design
- Constant Current mode output
- Built-in active PFC function
- No load/Standby power consumption <0.5W
- IP67/ |P65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer;
- 3 in 1 dimming (dim-to-off); Smart timer dimming; DALI;
- Typical lifetime>50000 hours
- 5 years warranty
Applications
- LED street lighting
- LED harbor lighting
- LED bay lighting
- LED greenhouse lighting
- LED flood lighting
Comply with class l application
Description
ELGT-150-C series is a 105~150W LED AC/DC class II driver featuring the constant current mode and high voltage output. ELGT-150-C operates from 100-305VAC and offers models with different rated current ranging between 700mA and 1400mA. Thanks to the high efficiency up to 92%, with the fanless design, the entire series is able to operate tor -40C~+90C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. ELGT-150-C is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
SPECIFICATION
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
This series works in constant current mode to directly drive the LEDs.
This characteristic applies to Blank/A/B/AB/D2-Type,For DA-Type, the Constant Current area is 60%-100% Vo.
DIMMING OPERATION
- DIM+for B/AB-Type
- DA+for DA-Type
- PROG+ for D2-Type
- DIM-for B/AB-Type
- DA-for DA-Type
- PROG-for D2-Type
X3 in 1 dimming function (for B/AB.Type)
Output constant current level can be adjusted by applying one of the three
methodologies between DIM+ and DIM-:
0-10VDC, or 10V PWM signal or resistance.
Direct connecting to LEDs is suggested. It is not suitable to be used with
additional drivers.
Dimming source current from power supply: 100uA (typ.)
Applying additive 0- 10VDC
Applying additive 10V PWM signal (frequency range 100Hz – 3KHz):
Applying additive resistance:
Note:
- Min. dimming level is about 8% and the output current is not defined when 0%< lout<8%.
- The output current could drop down to 0% when dimming input is about OkQ or OVdc, or 10V PWM signal with 0% duty cycle.
XDALI Interface (primary side; for DA-Type)
- Apply DALI signal between DA+ and DA-.
- DALI protocol comprises 16 groups and 64 addresses.
- First step is fixed at 8% of output.
Smart timer dimming function (for D2-Type by User definition)
MEAN WELL Smart timer dimming primarly provides the adaptive proportion
dimming profile for the output constant current level to perform up to 14
consecutive hours. 3 dimming profiles hereunder are defined accounting for the
most frequently seen applications. If other options may be needed,
please contact MEAN WELL for details.
Ex: D01-Type: the profile recommended for residential lighting
Set up for D01-Type in Smart timer dimming software program
| T1| T2| T3| T4
---|---|---|---|---
TIME| 06:00| 07:00| 11:00| —
LEVEL| 100%| 70%| 50%| 70%
: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.
Example: If a residential lighting application adopts DO1-Type, when turning on the power supply at 6:00pm, for instance:
- The power supply will switch to the constant current level at 100% starting from 6:00pm.
- The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on.
- The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 8:00am, which is 14:00 after the pOwer supply turns on.
Ex: D02-Type: the profile recommended for street lighting
Set up for D02-Type in Smart timer dimming software program:
| T1| T2| T3| T4| T5
---|---|---|---|---|---
TIME| 01:00| 03:00| 8:00| 11:00| —
LEVEL| 50%| 80%| 100%| 60%| 80%
IME matches Operating Iime in the diagram whereas LEVEL matches Dimming Level.
Example: lfa street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance:
- The power supply will switch to the constant current level at 50% starting from 5:00pm.
- The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on.
- The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on.
- The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on.
- The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The
constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
Ex: D03-Type: the profile recommended for tunnel lighting
Set up for D03-Type in Smart timer dimming software program:
| T1| T2| T3
---|---|---|---
TIME| 01:30| 11:00| —
LEVEL| 70%| 100%| 70%
: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.
Example: ía tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance:
- The power supply will switch to the constant current level at 70% starting from 4:30pm.
- The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
OUTPUT LOAD vs TEMPERATURE(NOTE 7.)
LIFE TIME
MECHANICAL SPECIFICATION
XBlank-Type
xB/DA/D2-Type
※ A-Type
※ AB-Type
MANUAL INSTALLATION
Please refer to : http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>