Product Information
This product is a fixture that can be mounted either to a junction box or directly to a wall. It comes with a cage, socket, shade, and necessary screws for assembly. The fixture is suitable for both indoor and outdoor use.
Product Usage Instructions
Mounting the Fixture to Junction Box:
- Remove the three screws (C) from the top and two screws from the bottom of the backplate to detach it from the fixture.
- Secure the mounting accessory (H) to the backplate to ensure the fixture is securely attached to the wall.
- Attach the fixture to the junction box following the provided instructions.
Mounting the Fixture Directly to Wall:
- Read the wiring and grounding instructions (IS 18) and any additional directions before proceeding.
- Turn off the power supply during installation.
- If new wiring is required, consult a qualified electrician or local authorities for code requirements.
- Place the cage (5) over the socket (2).
- Use the socket ring (4) to secure the cage (5).
- Secure the shade (3) to the cage (5) using screw (6).
- The fixture is now ready to be installed and wired accordingly.
Wiring Instructions:
For Indoor Fixtures:
- Connect the positive supply wire (A) to the positive fixture lead (B) using an appropriately sized twist-on connector. Refer to Drawings 1 or 2 for guidance.
- Connect the negative supply wire (C) to the negative fixture lead (D).
- Refer to the grounding instructions below to complete all electrical connections.
For Outdoor Fixtures:
- Connect the positive supply wire (A) to the positive fixture lead (B) using an appropriately sized twist-on connector. Refer to Drawings 2 or 3 for guidance.
- Connect the negative supply wire (C) to the negative fixture lead (D).
- Cover the open end of connectors with silicone sealant to create a watertight seal.
- If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall.
- If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
Please ensure that you read and follow all safety warnings, wiring instructions, and grounding instructions provided in the user manual before installing and using the product.
Assembly Instructions
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
Mounting fixture to junction box
-
To begin installation of your fixture it will first be necessary to remove the mounting plate (A) from the backplate (B). This is accomplished by first removing the three screws (C), located at the top and two on the lower side of the backplate. Set screws in a safe place for use later.
-
Next attach mounting plate (A) to junction box (J) with two screws (D), NOT PROVIDED. *
NOTE: make sure when installing mounting plate (A) that one of the tabs (T) is facing toward the ceiling and level, before tightening screws (D) – see Drawing 1. -
If plug is not being used. Remove plug and cover up hole in canopy using cover. Follow IS 18 on the next page to hardwire fixture
-
After all connections are made, tuck wires into junction box (J) and slip backplate (B) over mounting tabs (T) and align threaded holes in tab (T) with holes (H) in backplate (B).
-
Thread in screws (C) removed earlier, and tighten to secure fixture to wall.
-
Fixture can now be plugged in if fixture was not hardwired to junction box
DRAWING 1 – MOUNTING DRAWING 2- MOUNTING DIRECTLY TO WALL
Mounting fixture directly to wall
- To begin installation of your fixture it will first be necessary to remove the mounting plate (A) from the backplate (B). This is accomplished by first removing the three screws (C), located at the top and two on the lower side of the backplate. Set screws in a safe place for use later.
- Create holes in wall for mounting plate. Note: Use mounting plate to make sure holes are correctly spaced apart
- Place wall anchors (W) into created holes
- Secure mounting plate (A) by placing mounting plate up against wall aligned with wall anchors (W) and secures screws (D) to wall anchors
- Next slip backplate (B) over mounting tabs (T) and align threaded holes in tab (T) with holes (H) in backplate (B).
- Thread in screws (C) removed earlier, and tighten to secure fixture to wall.
- Fixture can now be plugged in using plug (1)
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-TIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
DRAWING 3 -Shade Assembly
- Place cage (5) over socket (2)
- Use socket ring (4) to secure cage (5)
- Secure shade (3) to cage (5) using screw (6) Fixture can now be lamped accordingly
I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
Wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Drawing 1 – Flush Mount
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
Drawing 2 – Chain Hung
Grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting
strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two
mounting screws in strap. Any remaining tapped hole may be used for the ground
screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
Drawing 3 – Post-Mount
LARK 33000 PIN OAK PARKWAY, AVON LAKE, OH 44012 LarkLiving.com