HORMANN Sliding Door Operator STA 500 FU for Entrance Gates Instruction Manual
- June 4, 2024
- HORMANN
Table of Contents
Instruction Manual
|
---|---
Instructions for fitting, operating, and maintenance
Sliding door operator STA 500 FU for entrance gates
Dissemination, as well as duplication of this document and the use and
communication of its content, are prohibited unless explicitly permitted.
Noncompliance will result in damage compensation obligations. All rights are
reserved in the event of patent, utility model, or design model registration.
Subject to changes.
Dear Customer,
We are delighted that you have chosen a quality product from our company.
About these instructions
These instructions are original operating instructions as outlined in the
EC Directive 2006/42/EC. Read through all of the instructions carefully, as
they contain important information about the product. Pay attention to and
follow the provided information, particularly the safety instructions and
warnings.
Please keep these instructions in a safe place and make sure that they are
available to all users at all times.
1.1 Further applicable documents
The following documents for safe handling and maintenance of the door system
must be placed at the disposal of the end user:
- These instructions
- The instructions for the control
- The sliding door operating instructions
- The enclosed log book
1 .2 Warnings used
** The general warning symbol indicates a danger that can lead to injury or death**. In the text, the general warning symbol will be used in connection with the caution levels described below. In the illustrated section, an additional instruction refers back to the explanation in the text section.
DANGER
Indicates a danger that immediately leads to death or serious injuries.
WARNING
Indicates a danger that can lead to death or serious injuries.
CAUTION
Indicates a danger that can lead to minor or moderate injuries.
ATTENTION
Indicates a danger that can lead to damage or destruction of the
product.
1 .3 Symbols used Icons
| Important note to prevent injury to persons and damage to property
---|---
| Permissible arrangement or activity
| Non-permissible arrangement or activity
| Check for ease of movement
| Check
1 .4 Notes on the illustrated section
The instructions show how to fit an operator on a closed sliding door on the
right interior side.
All specified dimensions in the illustrated section are in [mm].
1 .5 Accessories
Article designations
SKS| Closing edge safety device
WE| Maintenance release
HK| Crank handle
Safety instructions
ATTENTION:
IMPORTANT SAFETY INSTRUCTIONS.
FOR THE SAFETY OF PERSONS, IT IS IMPORTANT TO COMPLY WITH THE FOLLOWING
INSTRUCTIONS. THESE INSTRUCTIONS MUST BE KEPT.
2 .1 Intended use
This sliding door operator is intended for the operation of smooth-running
sliding doors in the industrial and commercial sectors. Note the manufacturer
specifications regarding the door and operator combination. Potential hazards
as outlined in DIN EN 13241 are prevented by construction and fitting
according to our specifications. Door systems that are located in a public
area and which only have one protective device, such as a power limit, may
only be operated under supervision.
Intended use also includes following all the notes provided in these
instructions, and complying with the maintenance instructions and country-
specific standards and safety regulations as well as the logbook.
2 .2 Non-intended use
The operator may not be used for doors with a gradient or slope unless the
door is equipped with a radial damper.
2 .3 Fitter qualification
Only correct fitting and maintenance in compliance with the instructions by a
competent/specialist company or a competent person/specialist ensures the safe
and flawless operation of the system.
According to EN 12635, a specialist is a person with suitable training,
specialist knowledge, and practical experience sufficient to correctly and
safely fit, test, and maintain a door system.
2 .4 Safety instructions for fitting, maintenance, repair, and dismantling
WARNING
The danger of injury due to insufficient inspection and maintenance
▶ See warning in section 5
The danger of injury due to unexpected door run
▶ See warning in section 5
The danger of injury during repairs and maintenance work
▶ See warning in section 5.1
Release
▶ See warning in section 5.2
Fitting, maintenance, repairs, and dismantling of the door system and the
sliding door operator must be performed by a specialist.
▶ In the event of a failure of the sliding door operator, a specialist must be
commissioned immediately to perform an inspection or carry out repairs.
2 .5 Safety instructions for fitting
The specialist carrying out the work must follow the applicable regulations
governing workplace safety and those governing the operation of electrical
equipment. In the process, the relevant national guidelines must be observed.
Potential hazards as outlined in EN 13241 are prevented by construction and
fitting according to our specifications.
After the fitting is complete, the specialist must declare conformity in
accordance with EN 13241 based on the area of application.
WARNING
The danger of injury due to unwanted door travel
▶ See warning in section 3.3
2 .6 Safety instructions for installation
**** | DANGER |
---|
Mains voltage
▶ See warning in section 3.7
ATTENTION
Damage due to incorrect electrical installation
▶ See warning in section 3.7
Faults in the system cables
▶ See warning in section 3.7
2 .7 Safety instructions for initial start-up and for operation
DANGER
Power limit adjustment
▶ See warning in section 4.1
WARNING
The danger of injury during door travel
▶ See warning in section 4.1
2 .8 Tested protective devices
The following functions or components, where available, meet cat. 2, PL “c” in
accordance with EN ISO 13849-1:2008 and were constructed and tested
accordingly:
- Internal power limit
- Tested protective devices
If such properties are needed for other functions or components, this must be tested individually.
WARNING
The danger of injuries due to faulty protective devices
▶ See warning in section 3.7
Fitting
ATTENTION:
IMPORTANT INSTRUCTIONS FOR SAFE FITTING.
FOLLOW ALL INSTRUCTIONS; INCORRECT FITTING CAN LEAD TO SERIOUS INJURIES.
The instructions show how to fit an operator on a sliding door.
All dimensions are in [mm].
3 .1
General rules
The sliding door system consists of the sliding door,
the safety equipment, the signal transmission to the
control and the operator unit with control.
3 .2 Testing the sliding door/sliding door system
The operator is not designed for the operation of sluggish sliding doors. Such
doors are either difficult or impossible to open or close manually.
The sliding door must be in flawless mechanical condition, as well as
correctly balanced so that it can be easily operated by hand (EN 12604).
▶ Check whether the door can be opened and closed correctly.
NOTE
A plinth foundation may be required for doors with track rollers on the
inside.
3 .3 Installing the operator
WARNING
Unintended door travel
Incorrectly fitted control devices (e.g. buttons) may trigger unwanted door
travel. Persons or objects may be trapped as a result.
****▶ Install control units at a height of at least 1.5 m (out of the reach
of children).
▶ Fit permanently installed control devices (such as buttons, etc.) within
sight of the door, but away from moving parts.
Please observe the following during fitting:
- The person carrying out the work must ensure that fitting is conducted in compliance with the applicable regulations governing workplace safety and those governing the operation of electrical equipment. The relevant national guidelines must be observed.
- According to BGR 232, at least one clearly visible and easily accessible emergency control device (emergency-off) must be installed in the vicinity of the leaves, which can be used in case of an emergency to stop the leaf movement.
- Secure the door mechanically against derailing from the guides.
- The mechanical locking devices of the door that are not needed for actuation with a sliding door operator must be put out of operation. This includes in particular any locking mechanisms connected with the door lock.
- In case the ambient temperature is too high or if directly exposed to the sun, the time the operator remains switched on is reduced to protect the electronic components. If required, install the operator protected accordingly.
- Check whether the supplied fitting materials are suitable for the intended fitting location. After the fitting is complete, the fitter of the door system must declare its conformity in accordance with EN 1324 based on the area of application.
ATTENTION
Damage caused by dirt
Drilling dust and chippings can lead to malfunctions.
▶ Cover the operator during drilling work.
3 .4 Fitting the toothed track
The height of the toothed track should be selected according to the adjustable height of the respective operator’s toothed wheel.
Depending on the door type, the toothed tracks can be attached to the door
profile via weld-on threaded bushings or distance sleeves with threaded holes
in the door profiles (ensure that the door profile wall thickness is
sufficient in this case!) (see Fig 1 .1a / Figure 1 .1b).
During fitting, ensure that the transitions between the individual toothed
tracks are not offset to ensure the smooth running of the door.
NOTE: Incorrectly fitted or poorly aligned toothed tracks can result in
unintended reverse travel. The provided dimensions must be complied with!
3 .5 Constructing the foundation
The position of the foundation must be determined based on the fixing method
used for the toothed track
(see Fig . 2). The distance between the center of the toothed track and
the center of the fastening hole in the base plate must be 93 mm to ensure the
full adjustment range later on.
Make sure that the foundation is frost-free *** (Germany = 80 cm).
The size of the foundation to be cast with concrete ≥ B25 / C25 (condensed)
can be found in Figures 2 .1a to 2 .1h.**
Lay the mains lead with 230 / 240 V ~ through a tube in the foundation. The
connecting lead for accessories with 24 V must be laid through a separate
tube, away from the mains lead (see Figure 2 .2).
NOTE: The foundation must be sufficiently hardened prior to the following
fitting steps.
3 .6 Fitting the operator unit
▶ If you have not done so already, remove the cover of the operator.
▶ Release the operator with the maintenance release.
▶ Align the operator on the cast foundation in such a way that the distance
between the center of the toothed track and the center of the fastening hole
in the base plate is 93 mm. This is the only way to allow ± 6 mm lateral
adjustment of the operator later on.
▶ Mark the drill holes and drill and clean them accordingly.
ATTENTION
Damage caused by dirt
During drilling work, drilling dust and chippings can lead to malfunctions.
▶ Cover the operator during drilling work.
▶ Place the anchor bolts.
▶ Check the parallel alignment of the operator to the toothed track and the
central alignment between the toothed track and toothed wheel, and adjust if
necessary.
▶ Tighten the anchor bolts with the specified torque.
▶ Raise the operator via the adjusting screws so that the gap between the
toothed track and the toothed wheel equals the dimension of approx. 2 mm
specified in the Figure.
▶ Tighten the top fastening nuts with the specified torque.
▶ Check again that the toothed track and operator are aligned in parallel.
It must be possible to fully open and close the door smoothly and without any
bucking.
▶ Half-close the door.
▶ Lock the operator again via the maintenance release.
3 .7 Electrical installation
Connect the control and the required accessories according to the instructions
for fitting, operating, and maintenance of the industrial door control for
sliding doors STA 500 FU.
▶ Close the cover after the electrical connection.
| DANGER
---|---
Mains voltage
Contact with the mains voltage presents the danger of a deadly electric shock.
For that reason, observe the following instructions under all circumstances:
▶ Electrical connections may only be made by a qualified electrician.
▶ The on-site electrical installation must conform to the applicable
protective regulations (230 V 1 AC, 50 / 60 Hz).
▶ Disconnect the system from the main supply and prevent it from being
switched on again without authorization.
WARNING
The danger of injury due to incorrect installation
Incorrect installation of the operator can result in serious injury.
▶ The on-site electrical installation must conform to the applicable
protective regulations.
▶ Electrical connections may only be made by a qualified electrician!
▶ Any further processing must ensure that the national regulations governing
the operation and fitting of electrical equipment are complied with.
WARNING
The danger of injuries due to faulty protective devices
In the event of a malfunction, there is a danger of injuries due to faulty
protective devices.
▶ The person commissioning the system must check the function(s) of the
protective device(s).
The system is only ready for operation after the function check.
ATTENTION
Damage due to incorrect electrical installation
Incorrect installation could result in damage. There- fore, be sure to
observe the following instructions.
▶ External voltage on the connecting terminals of the operator adapter print
will destroy the electronics.
▶ Never pull on the connecting cables of the electrical components, as this
will destroy the elect- Tronics.
▶ Be sure to feed the system cables into the housing from below.
▶ Use blind plugs to close off unused connections.
ATTENTION
Faults in the system cables
System cables and supply lines laid together can result in malfunctions.
▶ Lay the connection cables of the operator (24 V DC) in an installation
system that is separate from the supply lines (230 V 1 AC).
3 .8 Handing over the operating instructions
▶ After completing fitting and installation, hand the fitting, operating, and
maintenance instructions as well as the log book over to the operator of the
door system.
Initial start-up
Initial start-up of the door system – especially the operator – includes the following:
- Checking that the door system is easy to move (see door instructions)
- Switching on the energy supply
- Setting the operating parameters for the door system (control instructions)
- Checking the function of the protective devices
- Instructing operators and users
4 .1 Operation
DANGER
Power limit adjustment
The power limit can be adjusted in this operator (see operator
instructions).
Adjustment of the power limit can lead to serious injury and even death.
▶ Adjustment must be carried out by a specialist company. The liability of the
manufacturer for damages due to a deactivated power limit is excluded.
WARNING
**| The danger of injury during door travel
** If persons or objects are in the area of the door during door travel, this
can lead to injuries or damage.
▶ Children are not allowed to play near the door system.
▶ Make sure that no persons or objects are in the door’s area of travel.
▶ If the door system has only one protective device, only use the operator if
you are within view of the door.
▶ Monitor the door travel until the door has reached the end-of-travel
position.
▶ Do not drive or walk through the door openings during door closing.
▶ Never stand inside the open door.
The operator is responsible for complying with the following regulations
(without any claim to completeness): These are listed in the enclosed log
book.
4 .2 Instructing users
▶ All persons using the door system must be shown how to operate the operator
properly and safely.
4 .3 Emergency operation devices
ATTENTION
Use of the emergency operation devices
The door may only be operated via the emergency operation devices in case
of a malfunction. The use of emergency operation devices over a longer period
of time could lead to damage, rendering the warranty null and void.
▶ Only use the emergency operation devices in case of power failure or repair
work.
4 .3 .1 Emergency crank handle
NOTE:
Door operation via the emergency crank handle is only intended in case of a
malfunction (e.g. power failure).
▶ Open the housing (see Fig. 2.3).
▶ Switch the main switch off.
▶ Remove the emergency crank handle from the holder and insert it into the
corresponding receiver of the operator cap.
▶ Move the door in the desired direction by turning the crank handle.
▶ Then remove the crank handle again.
Maintenance instructions
WARNING
The danger of injury due to insufficient inspection and maintenance
Power-driven doors must be tested for safe condition by a specialist:
• Before initial start-up
• At least once a year
• At least every 6 months if actuated more than 50 times per day (corresponds
to approx. 10000 actuation)
Inadequate inspection and maintenance pose a danger of injury to persons and
damage to property.
▶ Contact your specialist company and arrange for the door to be regularly
inspected and maintained.
WARNING
The danger of injury due to unexpected door run
An unexpected door run may occur during inspection and maintenance work if
the door system is inadvertently actuated by third parties.
▶ Disconnect the door system from the power supply during inspection and
maintenance work.
▶ Safeguard the door system against being switched on again without
authorization.
A visual inspection may be carried out by the operator.
▶ Check all safety and protective functions monthly.
▶ Any malfunctions or defects must be rectified immediately by a specialist
company.
5 .1 Maintenance
WARNING
The danger of injury during repairs and maintenance work
A fault in the door system or an incorrectly aligned door can lead to
serious injuries.
▶ Do not use the door system if repair or adjustment work must be conducted.
5 .2 Maintenance release
CAUTION
Release
There is a danger of injury and damage in the door’s area of travel.
▶ The maintenance release may only be actuated by specialist personnel.
5 .3 Inspection instructions
Observe the inspection instructions for the door and control.
5 .3 .1 Gearbox
The operator gearbox features life-long lubrication and is maintenance-free.
▶ Make sure that the output and drive shaft are always free of rust.
5 .3 .2 Operator
If the operator is equipped with an FU, it must be inspected after 250000
cycles.
5 .3 .3 Connection elements
▶ Inspect all screws for corrosion, cracks, and a tight fit.
5 .3 .4 Electrical lines and components
▶ Check (if applicable):
– System cables for damages
– Resistance contact strips 8k2
Dismantling and disposal
When dismantling the system, observe the applicable regulations governing
workplace safety.
Have a specialist dismantle the operator in the reverse order of these
instructions and dispose of it properly. Electrical and electronic devices, as
well as batteries, must not be disposed of in household rubbish but must be
returned to the appropriate recycling facilities.
Warranty
For the warranty, the generally recognized terms and conditions or those
agreed in the delivery contract apply. The warranty does not apply for damage
resulting from insufficient knowledge of the provided operating instructions.
Structural changes made without our prior approval, or improper installations
carried out or initiated contrary to the fitting guidelines we have provided,
shall also render the warranty null and void. Furthermore, we will assume no
responsibility for the accidental or careless operation of the operator and
accessories, nor for improper maintenance of the door and its counterbalance.
Excerpt from the manufacturer’s declaration
(as defined in EC Machinery Directive 2006/42/EC according to Annex II, Part 1
A for a complete machine or Part 1 B for incorporation of an incomplete
machine) Fitting this operator is only permissible in combination with
specific door types approved for this purpose. These door types can be found
in the complete EC / EU declaration of conformity in the provided log book.
When combining this operator with a door, the fitter is considered a
manufacturer of the complete machine.
Therefore, fitting may only be done by a fitting company, as only they have
knowledge of the relevant safety regulations, valid directives, and standards,
as well as the required testing and measuring devices. The appropriate
manufacturer’s declaration can also be found in the provided log book.
Technical data
Chain drive operator: | STA 500 FU |
---|---|
Operator speed | rpm |
Operating voltage | V |
Frequency | Hz |
Motor power | kW |
Cycles per hour | |
Max. door travel speed | cm/s |
Nominal force | N |
Max. pull and push force | N |
Shaft diameter | mm |
Protection category | |
Ambient temperature | °C |
Oil | |
Connection | |
Airborne sound emission | dB(A) |
STA 500 FU
HÖRMANN KG Verkaufsgesellschaft
Upheider Weg 94-98
33803 Steinhagen
Deutschland
4552661 B1
00000003222000004552661B1
Documents / Resources
|
HORMANN Sliding Door Operator STA 500 FU for Entrance
Gates
[pdf] Instruction Manual
Sliding Door Operator STA 500 FU for Entrance Gates, Sliding Door Operator STA
500 FU, Sliding Door Operator, STA 500 FU
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>