SALTO XS4 Panel Wall Reader Installation Guide
- June 9, 2024
- SALTO
Table of Contents
SALTO XS4 Panel Wall Reader
The SALTO panel reader is designed to be integrated behind lift panels, door intercoms, electric switches or turnstiles and gates. It can be installed behind metal plates but needs a window which is necessary for the reader antenna operation. It works in conjunction with SALTO controller
DIMENSIONS
Installation
Application
Electrical characteristics
Operation conditions
Min. | Max. Unit |
---|---|
Temperature WRDP0B | -30 |
Temperature WRDP0J | -25 |
Humidity | 35 |
RF characteristics
Min | Cen. | Max. |
---|
RFID frequency
Bluetooth Smart 2.4 frequency
| 13.56
2.445
|
2.4835
| Mhz
Ghz
Cable type and max. distances
Cable type Reader
UTP Cat5e 2 pairs 279ft
AWG24 85m
UTP Cat5e 4 pairs 853ft AWG24 + 260m
SP224861/SP224895 Note2
Twisted pairs 1312ft
AWG18 400m
Power Consumption Note1
Min | Max | Unit |
---|---|---|
Reader | 150 | mA |
Note 1 : Installer must take this data into account to dimension the CU42xx power supply. Panel Reader only for use with the SALTO Control Units. SALTO recommends to use one cable per wall reader
Installation example
Installation example CU42xx:
Installation example CU41xY:
Installation example with RJ45
Installation example CU41xY with RJ45xx
All contents current at time of publication.SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. © 2022 SALTO Systems S.L. 225648 -ED.3 -14/11/2022