BEA Universal Remote Control User Guide

June 4, 2024
BEA

Universal Remote Control
User GuideBEA Universal Remote Control

GENERAL KEYS

| Unlock
---|---
| Lock
| Check value
| Incremental increase
| Incremental decrease
| Setup / Teach-in Factory values Pre settings

FUNCTION KEYS

See pages 3 – 12 for button assignments per product.

COLOR KEYS

| LZR-FLATSCAN| LZR-WIDE SCAN
---|---|---
| /| Virtual Pull Cord
| Safety| Safety
| Motion| Reopening
| /| Presence

GENERAL REMOTE USE

BEA Universal Remote Control - key 1

ADJUSTING ONE OR MORE PARAMETERS

BEA Universal Remote Control - key 2

CHECKING A VALUE

BEA Universal Remote Control - key 3

RESTORING TO FACTORY VALUES

BEA Universal Remote Control - key 4

SAVING AN ACCESS CODE

BEA Universal Remote Control - key 5

The access code (1 – 4 digits) is recommended to set sensors that are installed close to each other.

CHANGING AN ACCESS CODE

BEA Universal Remote Control - key 6

DELETING AN ACCESS CODE

BEA Universal Remote Control - key 7

If you forget the access code, proceed as follows:

BEA Universal Remote Control - key 8

BEA Universal Remote Control - icon 12

APPENDIX: LZR-I30 / LZR-S600 FUNCTIONS

BEA Universal Remote Control - FUNCTIONS 1BEA
Universal Remote Control - FUNCTIONS 2BEA
Universal Remote Control - FUNCTIONS 3BEA
Universal Remote Control - FUNCTIONS 4BEA
Universal Remote Control - FUNCTIONS 5

1 EAGLE default = 8, EAGLEHM default = 7
2 EAGLE default = 1, EAGLEHM default = 2BEA Universal Remote Control -
FUNCTIONS 6BEA Universal Remote Control - FUNCTIONS
7BEA Universal Remote Control - FUNCTIONS
8BEA Universal Remote Control - FUNCTIONS
9

  1. V5.0 auto-synch

  2. for use with IXIO if synchronization issues occur

  3. The sensor LED will briefly flash RED during monitoring communication with the door control. This indicates that external monitoring is
    functional. Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control.

  4. Partial reset is only available via remote control. Partial restores all adjustable settings except Out1Logic and Out2Logic.

BEA Universal Remote Control - FUNCTIONS 10

  1. MTF = motion tracking feature
  2. DeEner = de-energized relay, Energ = energized relay, N.O. = normally open, N.C. = normally closed
  3. The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control.
  4. active opening output: 0 = motion detection, 1 = motion or presence detection
  5. 0 = presence detection on safety input, 1 = presence detection on safety + auxiliary inputs
  6. partial: outputs are not reset

©BEA | Original Instructions
75.0043.02 REMOTE CONTROL 20220322